-
Predicting successful clinical candidates for fiducial-free lung tumor tracking with a deep learning binary classification model
Authors:
Matthieu Lafrenière,
Gilmer Valdes,
Martina Descovich
Abstract:
The CyberKnife system is a robotic radiosurgery platform that allows the delivery of lung SBRT treatments using fiducial-free soft-tissue tracking. However, not all lung cancer patients are eligible for lung tumor tracking. Tumor size, density and location impact the ability to successfully detect and track a lung lesion in 2D orthogonal X-ray images. The standard workflow to identify successful c…
▽ More
The CyberKnife system is a robotic radiosurgery platform that allows the delivery of lung SBRT treatments using fiducial-free soft-tissue tracking. However, not all lung cancer patients are eligible for lung tumor tracking. Tumor size, density and location impact the ability to successfully detect and track a lung lesion in 2D orthogonal X-ray images. The standard workflow to identify successful candidates for lung tumor tracking is called Lung Optimized Treatment (LOT) simulation, and involves multiple steps from CT acquisition to the execution of the simulation plan on CyberKnife. The aim of the study is to develop a deep learning classification model to predict which patients can be successfully treated with lung tumor tracking, thus circumventing the LOT simulation process.
Target tracking is achieved by matching orthogonal x-ray images with a library of digital radiographs reconstructed from the simulation CT scan (DRRs). We developed a deep learning model to create a binary classification of lung lesions as being trackable or untrackable based on tumor template DRR extracted from the CyberKnife system, and tested five different network architectures. The study included a total of 271 images (230 trackable, 41 untrackable) from 129 patients with one or multiple lung lesions. 80% of the images were used for training, 10% for validation, and the remaining 10% for testing.
For all 5 convolutional neural networks, the binary classification accuracy reached 100% after training, both in the validation and the test set, without any false classifications.
A deep learning model can distinguish features of trackable and untrackable lesions in DRR images, and can predict successful candidates for fiducial-free lung tumor tracking.
△ Less
Submitted 23 August, 2023; v1 submitted 10 October, 2022;
originally announced October 2022.
-
A characterization method for low-frequency environmental noise in LIGO
Authors:
Guillermo Valdes,
Adam Hines,
Andrea Nelson,
Yanqi Zhang,
Felipe Guzman
Abstract:
We present a method to characterize the noise in ground-based gravitational-wave observatories such as the Laser Gravitational-Wave Observatory (LIGO). This method uses linear regression algorithms such as the least absolute shrinkage and selection operator (LASSO) to identify noise sources and analyzes the detector output versus noise witness sensors to quantify the coupling of such noise. Our me…
▽ More
We present a method to characterize the noise in ground-based gravitational-wave observatories such as the Laser Gravitational-Wave Observatory (LIGO). This method uses linear regression algorithms such as the least absolute shrinkage and selection operator (LASSO) to identify noise sources and analyzes the detector output versus noise witness sensors to quantify the coupling of such noise. Our method can be implemented with currently available resources at LIGO, which avoids extra coding or direct experimentation at the LIGO sites. We present two examples to validate and estimate the coupling of elevated ground motion at frequencies below 10 Hz with noise in the detector output.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
Investigation and mitigation of noise contributions in a compact heterodyne interferometer
Authors:
Yanqi Zhang,
Adam Hines,
Guillermo Valdes,
Felipe Guzman
Abstract:
We present a noise estimation and subtraction algorithm capable of increasing the sensitivity of heterodyne laser interferometers by one order of magnitude. The heterodyne interferometer is specially designed for dynamic measurements of a test mass in the application of sub-Hz inertial sensing. A noise floor of 3.31E-11 m/rtHz at 100mHz is achieved after applying our noise subtraction algorithm to…
▽ More
We present a noise estimation and subtraction algorithm capable of increasing the sensitivity of heterodyne laser interferometers by one order of magnitude. The heterodyne interferometer is specially designed for dynamic measurements of a test mass in the application of sub-Hz inertial sensing. A noise floor of 3.31E-11 m/rtHz at 100mHz is achieved after applying our noise subtraction algorithm to a benchtop prototype interferometer that showed a noise level of 2.76E-10 m/rtHz at 100mHz when tested in vacuum at levels of 3E-5 Torr. Based on the previous results, we investigated noise estimation and subtraction techniques of non-linear optical pathlength noise, laser frequency noise, and temperature fluctuations in heterodyne laser interferometers. For each noise source, we identified its contribution and removed it from the measurement by linear fitting or a spectral analysis algorithm. The noise correction algorithm we present in this article can be generally applied to heterodyne laser interferometers.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
Optomechanical accelerometers for geodesy
Authors:
Adam Hines,
Andrea Nelson,
Yanqi Zhang,
Guillermo Valdes,
Jose Sanjuan,
Jeremiah Stoddart,
Felipe Guzman
Abstract:
We present a novel optomechanical inertial sensor for low frequency applications and corresponding acceleration measurements. This sensor has a resonant frequency of 4.7Hz, a mechanical quality factor of 476k, a test mass of 2.6 gram, and a projected noise floor of approximately 5E-11 m s-2. per root-Hz at 1Hz. Such performance, together with its small size, low weight, reduced power consumption,…
▽ More
We present a novel optomechanical inertial sensor for low frequency applications and corresponding acceleration measurements. This sensor has a resonant frequency of 4.7Hz, a mechanical quality factor of 476k, a test mass of 2.6 gram, and a projected noise floor of approximately 5E-11 m s-2. per root-Hz at 1Hz. Such performance, together with its small size, low weight, reduced power consumption, and low susceptibility to environmental variables such as magnetic field or drag conditions makes it an attractive technology for future geodesy missions. In this paper, we present an experimental demonstration of low-frequency ground seismic noise detection by direct comparison with a commercial seismometer, anda data analysis algorithms for the identification, characterization, and correction of several noise sources.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
Daily monitoring of scattered light noise due to microseismic variability at the Virgo interferometer
Authors:
Alessandro Longo,
Stefano Bianchi,
Guillermo Valdes,
Nicolas Arnaud,
Wolfango Plastino
Abstract:
Data acquired by the Virgo interferometer during the second part of the O3 scientific run, referred to as O3b, were analysed with the aim of characterising the onset and time evolution of scattered light noise in connection with the variability of microseismic noise in the environment surrounding the detector. The adaptive algorithm used, called pytvfemd, is suitable for the analysis of time serie…
▽ More
Data acquired by the Virgo interferometer during the second part of the O3 scientific run, referred to as O3b, were analysed with the aim of characterising the onset and time evolution of scattered light noise in connection with the variability of microseismic noise in the environment surrounding the detector. The adaptive algorithm used, called pytvfemd, is suitable for the analysis of time series which are both nonlinear and nonstationary. It allowed to obtain the first oscillatory mode of the differential arm motion degree of freedom of the detector during days affected by scattered light noise. The mode's envelope i.e., its instantaneous amplitude, is then correlated with the motion of the West end bench, a known source of scattered light during O3. The relative velocity between the West end test mass and the West end optical bench is used as a predictor of scattered light noise. Higher values of correlation are obtained in periods of higher seismic noise in the microseismic frequency band. This is also confirmed by the signal-to-noise ratio (SNR) of scattered light glitches from GravitySpy for the January-March 2020 period. Obtained results suggest that the adopted methodology is suited for scattered light noise characterisation and monitoring in gravitational wave interferometers.
△ Less
Submitted 11 December, 2021;
originally announced December 2021.
-
Point Absorber Limits to Future Gravitational-Wave Detectors
Authors:
W. Jia,
H. Yamamoto,
K. Kuns,
A. Effler,
M. Evans,
P. Fritschel,
R. Abbott,
C. Adams,
R. X. Adhikari,
A. Ananyeva,
S. Appert,
K. Arai,
J. S. Areeda,
Y. Asali,
S. M. Aston,
C. Austin,
A. M. Baer,
M. Ball,
S. W. Ballmer,
S. Banagiri,
D. Barker,
L. Barsotti,
J. Bartlett,
B. K. Berger,
J. Betzwieser
, et al. (176 additional authors not shown)
Abstract:
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some hig…
▽ More
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically, and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in-situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational wave detectors that support high optical power, and thus reduce quantum noise.
△ Less
Submitted 17 September, 2021;
originally announced September 2021.
-
Gwadaptive_scattering: an automated pipeline for scattered light noise characterization
Authors:
Stefano Bianchi,
Alessandro Longo,
Guillermo Valdes,
Gabriela González,
Wolfango Plastino
Abstract:
Scattered light noise affects the sensitivity of gravitational waves detectors. The characterization of such noise is needed to mitigate it. The time-varying filter empirical mode decomposition algorithm is suitable for identifying signals with time-dependent frequency such as scattered light noise (or scattering). We present a fully automated pipeline based on the pytvfemd library, a python imple…
▽ More
Scattered light noise affects the sensitivity of gravitational waves detectors. The characterization of such noise is needed to mitigate it. The time-varying filter empirical mode decomposition algorithm is suitable for identifying signals with time-dependent frequency such as scattered light noise (or scattering). We present a fully automated pipeline based on the pytvfemd library, a python implementation of the tvf-EMD algorithm, to identify objects inducing scattering in the gravitational-wave channel with their motion. The pipeline application to LIGO Livingston O3 data shows that most scattering noise is due to the penultimate mass at the end of the X-arm of the detector (EXPUM) and with a motion in the micro-seismic frequency range.
△ Less
Submitted 15 July, 2021;
originally announced July 2021.
-
LIGOs Quantum Response to Squeezed States
Authors:
L. McCuller,
S. E. Dwyer,
A. C. Green,
Haocun Yu,
L. Barsotti,
C. D. Blair,
D. D. Brown,
A. Effler,
M. Evans,
A. Fernandez-Galiana,
P. Fritschel,
V. V. Frolov,
N. Kijbunchoo,
G. L. Mansell,
F. Matichard,
N. Mavalvala,
D. E. McClelland,
T. McRae,
A. Mullavey,
D. Sigg,
B. J. J. Slagmolen,
M. Tse,
T. Vo,
R. L. Ward,
C. Whittle
, et al. (172 additional authors not shown)
Abstract:
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to furth…
▽ More
Gravitational Wave interferometers achieve their profound sensitivity by combining a Michelson interferometer with optical cavities, suspended masses, and now, squeezed quantum states of light. These states modify the measurement process of the LIGO, VIRGO and GEO600 interferometers to reduce the quantum noise that masks astrophysical signals; thus, improvements to squeezing are essential to further expand our gravitational view of the universe. Further reducing quantum noise will require both lowering decoherence from losses as well more sophisticated manipulations to counter the quantum back-action from radiation pressure. Both tasks require fully understanding the physical interactions between squeezed light and the many components of km-scale interferometers. To this end, data from both LIGO observatories in observing run three are expressed using frequency-dependent metrics to analyze each detector's quantum response to squeezed states. The response metrics are derived and used to concisely describe physical mechanisms behind squeezing's simultaneous interaction with transverse-mode selective optical cavities and the quantum radiation pressure noise of suspended mirrors. These metrics and related analysis are broadly applicable for cavity-enhanced optomechanics experiments that incorporate external squeezing, and -- for the first time -- give physical descriptions of every feature so far observed in the quantum noise of the LIGO detectors.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Point absorbers in Advanced LIGO
Authors:
Aidan F. Brooks,
Gabriele Vajente,
Hiro Yamamoto,
Rich Abbott,
Carl Adams,
Rana X. Adhikari,
Alena Ananyeva,
Stephen Appert,
Koji Arai,
Joseph S. Areeda,
Yasmeen Asali,
Stuart M. Aston,
Corey Austin,
Anne M. Baer,
Matthew Ball,
Stefan W. Ballmer,
Sharan Banagiri,
David Barker,
Lisa Barsotti,
Jeffrey Bartlett,
Beverly K. Berger,
Joseph Betzwieser,
Dripta Bhattacharjee,
Garilynn Billingsley,
Sebastien Biscans
, et al. (176 additional authors not shown)
Abstract:
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback contro…
▽ More
Small, highly absorbing points are randomly present on the surfaces of the main interferometer optics in Advanced LIGO. The resulting nano-meter scale thermo-elastic deformations and substrate lenses from these micron-scale absorbers significantly reduces the sensitivity of the interferometer directly though a reduction in the power-recycling gain and indirect interactions with the feedback control system. We review the expected surface deformation from point absorbers and provide a pedagogical description of the impact on power build-up in second generation gravitational wave detectors (dual-recycled Fabry-Perot Michelson interferometers). This analysis predicts that the power-dependent reduction in interferometer performance will significantly degrade maximum stored power by up to 50% and hence, limit GW sensitivity, but suggests system wide corrections that can be implemented in current and future GW detectors. This is particularly pressing given that future GW detectors call for an order of magnitude more stored power than currently used in Advanced LIGO in Observing Run 3. We briefly review strategies to mitigate the effects of point absorbers in current and future GW wave detectors to maximize the success of these enterprises.
△ Less
Submitted 25 March, 2021; v1 submitted 14 January, 2021;
originally announced January 2021.
-
Improving the Robustness of the Advanced LIGO Detectors to Earthquakes
Authors:
Eyal Schwartz,
A Pele,
J Warner,
B Lantz,
J Betzwieser,
K L Dooley,
S Biscans,
M Coughlin,
N Mukund,
R Abbott,
C Adams,
R X Adhikari,
A Ananyeva,
S Appert,
K Arai,
J S Areeda,
Y Asali,
S M Aston,
C Austin,
A M Baer,
M Ball,
S W Ballmer,
S Banagiri,
D Barker,
L Barsotti
, et al. (174 additional authors not shown)
Abstract:
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differenti…
▽ More
Teleseismic, or distant, earthquakes regularly disrupt the operation of ground--based gravitational wave detectors such as Advanced LIGO. Here, we present \emph{EQ mode}, a new global control scheme, consisting of an automated sequence of optimized control filters that reduces and coordinates the motion of the seismic isolation platforms during earthquakes. This, in turn, suppresses the differential motion of the interferometer arms with respect to one another, resulting in a reduction of DARM signal at frequencies below 100\,mHz. Our method greatly improved the interferometers' capability to remain operational during earthquakes, with ground velocities up to 3.9\,$μ\mbox{m/s}$ rms in the beam direction, setting a new record for both detectors. This sets a milestone in seismic controls of the Advanced LIGO detectors' ability to manage high ground motion induced by earthquakes, opening a path for further robust operation in other extreme environmental conditions.
△ Less
Submitted 24 July, 2020;
originally announced July 2020.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.