An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules
Authors:
A. Tishelman-Charny,
A. Affolder,
F. Capocasa,
E. Duden,
V. Fadeyev,
M. Gignac,
C. Helling,
H. Herde,
J. Johnson,
D. Lynn,
M. Morii,
A. Mitra,
L. Poley,
G. Sciolla,
S. Stucci,
P. Sharma,
G. Van Nieuwenhuizen,
E. Wallin,
A. Wang,
S. Wonsak
Abstract:
At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracke…
▽ More
At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about ${-35}^\circ$C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times - this study is also described.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
An alkali-referenced vector spectrum analyzer for visible-light integrated photonics
Authors:
Baoqi Shi,
Ming-Yang Zheng,
Yunkai Zhao,
Yi-Han Luo,
Jinbao Long,
Wei Sun,
Wenbo Ma,
Xiu-Ping Xie,
Lan Gao,
Chen Shen,
Anting Wang,
Wei Liang,
Qiang Zhang,
Junqiu Liu
Abstract:
Integrated photonics has reformed our information society by offering on-chip optical signal synthesis, processing and detection with reduced size, weight and power consumption. As such, it has been successfully established in the near-infrared (NIR) telecommunication bands. With the soaring demand in miniaturized systems for biosensing, quantum information and transportable atomic clocks, extensi…
▽ More
Integrated photonics has reformed our information society by offering on-chip optical signal synthesis, processing and detection with reduced size, weight and power consumption. As such, it has been successfully established in the near-infrared (NIR) telecommunication bands. With the soaring demand in miniaturized systems for biosensing, quantum information and transportable atomic clocks, extensive endeavors have been stacked on translating integrated photonics into the visible spectrum, i.e. visible-light integrated photonics. Various innovative visible-light integrated devices have been demonstrated, such as lasers, frequency combs, and atom traps, highlighting the capacity and prospect to create chip-based optical atomic clocks that can make timing and frequency metrology ubiquitous. A pillar to the development of visible-light integrated photonics is characterization techniques featuring high frequency resolution and wide spectral coverage, which however remain elusive. Here, we demonstrate a vector spectrum analyzer (VSA) for visible-light integrated photonics, offering spectral bandwidth from 766 to 795 nm and frequency resolution of 415 kHz. The VSA is rooted on a widely chirping, high-power, narrow-linewidth, mode-hop-free laser around 780 nm, which is frequency-doubled from the near-infrared via an efficient, broadband CPLN waveguide. The VSA is further referenced to hyperfine structures of rubidium and potassium atoms, enabling 8.1 MHz frequency accuracy. We apply our VSA to showcase the characterization of loss, dispersion and phase response of passive integrated devices, as well as densely spaced spectra of mode-locked lasers. Combining operation in the NIR and visible spectra, our VSA allows characterization bandwidth exceeding an octave and can be an invaluable diagnostic tool for spectroscopy, nonlinear optical processing, imaging and quantum interfaces to atomic devices.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 20 June, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Camera and Readout for the Trinity Demonstrator and the EUSO-SPB2 Cherenkov Telescope
Authors:
Mahdi Bagheri,
Srikar Gadamsetty,
Eliza Gazda,
Eleanor Judd,
Evgeny Kuznetsov,
A. Nepomuk Otte,
Mathew Potts,
Oscar Romero Matamala,
Noah Shapera,
Joshua Sorell,
Svanik Tandon,
Andrew Wang
Abstract:
We developed a modular silicon photomultiplier camera to detect Earth-skimming PeV to EeV tau neutrinos with the imaging atmospheric Cherenkov technique. We built two cameras, a 256-pixel camera with S14161-6050HS SiPMs for the Trinity Demonstrator located on Frisco Peak, Utah, and a 512-pixel camera with S14521-6050AN SiPMs for the EUSO-SPB2 Cherenkov Telescope. The front-end electronics are base…
▽ More
We developed a modular silicon photomultiplier camera to detect Earth-skimming PeV to EeV tau neutrinos with the imaging atmospheric Cherenkov technique. We built two cameras, a 256-pixel camera with S14161-6050HS SiPMs for the Trinity Demonstrator located on Frisco Peak, Utah, and a 512-pixel camera with S14521-6050AN SiPMs for the EUSO-SPB2 Cherenkov Telescope. The front-end electronics are based on the eMUSIC ASIC, and the camera signals are sampled and digitized with the 100MS/s and 12-bit AGET system. Both cameras are liquid-cooled. We detail the camera concept and the results from characterizing the SiPMs, bench testing, and calibrating the two cameras.
△ Less
Submitted 12 June, 2024;
originally announced June 2024.
-
SwdFold:A Reweighting and Unfolding method based on Optimal Transport Theory
Authors:
Chu-Cheng Pan,
Xiang Dong,
Yu-Chang Sun,
Ao-Yan Cheng,
Ao-Bo Wang,
Yu-Xuan Hu,
Hao Cai
Abstract:
High-energy physics experiments rely heavily on precise measurements of energy and momentum, yet face significant challenges due to detector limitations, calibration errors, and the intrinsic nature of particle interactions. Traditional unfolding techniques have been employed to correct for these distortions, yet they often suffer from model dependency and stability issues. We present a novel meth…
▽ More
High-energy physics experiments rely heavily on precise measurements of energy and momentum, yet face significant challenges due to detector limitations, calibration errors, and the intrinsic nature of particle interactions. Traditional unfolding techniques have been employed to correct for these distortions, yet they often suffer from model dependency and stability issues. We present a novel method, SwdFold, which utilizes the principles of optimal transport to provide a robust, model-independent framework to estimate the probability density ratio for data unfolding. It not only unfold the toy experimental event by reweighted simulated data distributions closely with true distributions but also maintains the integrity of physical features across various observables. We can expect it can enable more reliable predictions and comprehensive analyses as a high precision reweighting and unfolding tool in high-energy physics.
△ Less
Submitted 2 June, 2024;
originally announced June 2024.
-
MANTA: A Negative-Triangularity NASEM-Compliant Fusion Pilot Plant
Authors:
MANTA Collaboration,
G. Rutherford,
H. S. Wilson,
A. Saltzman,
D. Arnold,
J. L. Ball,
S. Benjamin,
R. Bielajew,
N. de Boucaud,
M. Calvo-Carrera,
R. Chandra,
H. Choudhury,
C. Cummings,
L. Corsaro,
N. DaSilva,
R. Diab,
A. R. Devitre,
S. Ferry,
S. J. Frank,
C. J. Hansen,
J. Jerkins,
J. D. Johnson,
P. Lunia,
J. van de Lindt,
S. Mackie
, et al. (16 additional authors not shown)
Abstract:
The MANTA (Modular Adjustable Negative Triangularity ARC-class) design study investigated how negative-triangularity (NT) may be leveraged in a compact, fusion pilot plant (FPP) to take a ``power-handling first" approach. The result is a pulsed, radiative, ELM-free tokamak that satisfies and exceeds the FPP requirements described in the 2021 National Academies of Sciences, Engineering, and Medicin…
▽ More
The MANTA (Modular Adjustable Negative Triangularity ARC-class) design study investigated how negative-triangularity (NT) may be leveraged in a compact, fusion pilot plant (FPP) to take a ``power-handling first" approach. The result is a pulsed, radiative, ELM-free tokamak that satisfies and exceeds the FPP requirements described in the 2021 National Academies of Sciences, Engineering, and Medicine report ``Bringing Fusion to the U.S. Grid". A self-consistent integrated modeling workflow predicts a fusion power of 450 MW and a plasma gain of 11.5 with only 23.5 MW of power to the scrape-off layer (SOL). This low $P_\text{SOL}$ together with impurity seeding and high density at the separatrix results in a peak heat flux of just 2.8 MW/m$^{2}$. MANTA's high aspect ratio provides space for a large central solenoid (CS), resulting in ${\sim}$15 minute inductive pulses. In spite of the high B fields on the CS and the other REBCO-based magnets, the electromagnetic stresses remain below structural and critical current density limits. Iterative optimization of neutron shielding and tritium breeding blanket yield tritium self-sufficiency with a breeding ratio of 1.15, a blanket power multiplication factor of 1.11, toroidal field coil lifetimes of $3100 \pm 400$ MW-yr, and poloidal field coil lifetimes of at least $890 \pm 40$ MW-yr. Following balance of plant modeling, MANTA is projected to generate 90 MW of net electricity at an electricity gain factor of ${\sim}2.4$. Systems-level economic analysis estimates an overnight cost of US\$3.4 billion, meeting the NASEM FPP requirement that this first-of-a-kind be less than US\$5 billion. The toroidal field coil cost and replacement time are the most critical upfront and lifetime cost drivers, respectively.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (190 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Real-time equilibrium reconstruction by neural network based on HL-3 tokamak
Authors:
Guohui Zheng,
Songfen Liu,
Zongyu Yang,
Rui Ma,
Xinwen Gong,
Ao Wang,
Shuo Wang,
Wulyu Zhong
Abstract:
A neural network model, EFITNN, has been developed capable of real-time magnetic equilibrium reconstruction based on HL-3 tokamak magnetic measurement signals. The model processes inputs from 68 channels of magnetic measurement data gathered from 1159 HL-3 experimental discharges, including plasma current, loop voltage, and the poloidal magnetic fields measured by equilibrium probes. The outputs o…
▽ More
A neural network model, EFITNN, has been developed capable of real-time magnetic equilibrium reconstruction based on HL-3 tokamak magnetic measurement signals. The model processes inputs from 68 channels of magnetic measurement data gathered from 1159 HL-3 experimental discharges, including plasma current, loop voltage, and the poloidal magnetic fields measured by equilibrium probes. The outputs of the model feature eight key plasma parameters, alongside high-resolution ($129\times129$) reconstructions of the toroidal current density $J_{\text P}$ and poloidal magnetic flux profiles $Ψ_{rz}$. Moreover, the network's architecture employs a multi-task learning structure, which enables the sharing of weights and mutual correction among different outputs, and lead to increase the model's accuracy by up to 32%. The performance of EFITNN demonstrates remarkable consistency with the offline EFIT, achieving average $R^2 = 0.941, 0.997$ and $0.959$ for eight plasma parameters, $Ψ_{rz}$ and $J_{\text P}$, respectively. The model's robust generalization capabilities are particularly evident in its successful predictions of quasi-snowflake (QSF) divertor configurations and its adept handling of data from shot numbers or plasma current intervals not previously encountered during training. Compared to numerical methods, EFITNN significantly enhances computational efficiency with average computation time ranging from 0.08ms to 0.45ms, indicating its potential utility in real-time isoflux control and plasma profile management.
△ Less
Submitted 18 May, 2024;
originally announced May 2024.
-
Acceptance Tests of more than 10 000 Photomultiplier Tubes for the multi-PMT Digital Optical Modules of the IceCube Upgrade
Authors:
R. Abbasi,
M. Ackermann,
J. Adams,
S. K. Agarwalla,
J. A. Aguilar,
M. Ahlers,
J. M. Alameddine,
N. M. Amin,
K. Andeen,
C. Argüelles,
Y. Ashida,
S. Athanasiadou,
L. Ausborm,
S. N. Axani,
X. Bai,
A. Balagopal V.,
M. Baricevic,
S. W. Barwick,
S. Bash,
V. Basu,
R. Bay,
J. J. Beatty,
J. Becker Tjus,
J. Beise,
C. Bellenghi
, et al. (399 additional authors not shown)
Abstract:
More than 10,000 photomultiplier tubes (PMTs) with a diameter of 80 mm will be installed in multi-PMT Digital Optical Modules (mDOMs) of the IceCube Upgrade. These have been tested and pre-calibrated at two sites. A throughput of more than 1000 PMTs per week with both sites was achieved with a modular design of the testing facilities and highly automated testing procedures. The testing facilities…
▽ More
More than 10,000 photomultiplier tubes (PMTs) with a diameter of 80 mm will be installed in multi-PMT Digital Optical Modules (mDOMs) of the IceCube Upgrade. These have been tested and pre-calibrated at two sites. A throughput of more than 1000 PMTs per week with both sites was achieved with a modular design of the testing facilities and highly automated testing procedures. The testing facilities can easily be adapted to other PMTs, such that they can, e.g., be re-used for testing the PMTs for IceCube-Gen2. Single photoelectron response, high voltage dependence, time resolution, prepulse, late pulse, afterpulse probabilities, and dark rates were measured for each PMT. We describe the design of the testing facilities, the testing procedures, and the results of the acceptance tests.
△ Less
Submitted 20 June, 2024; v1 submitted 30 April, 2024;
originally announced April 2024.
-
"Beam `a la carte": laser heater shaping for attosecond pulses in a multiplexed x-ray free-electron laser
Authors:
Siqi Li,
Zhen Zhang,
Shawn Alverson,
David Cesar,
Taran Driver,
Paris Franz,
Erik Isele,
Joseph P. Duris,
Kirk Larsen,
Ming-Fu Lin,
Razib Obaid,
Jordan T O'Neal,
River Robles,
Nick Sudar,
Zhaoheng Guo,
Sharon Vetter,
Peter Walter,
Anna L. Wang,
Joseph Xu,
Sergio Carbajo,
James P. Cryan,
Agostino Marinelli
Abstract:
Electron beam shaping allows the control of the temporal properties of x-ray free-electron laser pulses from femtosecond to attosecond timescales. Here we demonstrate the use of a laser heater to shape electron bunches and enable the generation of attosecond x-ray pulses. We demonstrate that this method can be applied in a selective way, shaping a targeted subset of bunches while leaving the remai…
▽ More
Electron beam shaping allows the control of the temporal properties of x-ray free-electron laser pulses from femtosecond to attosecond timescales. Here we demonstrate the use of a laser heater to shape electron bunches and enable the generation of attosecond x-ray pulses. We demonstrate that this method can be applied in a selective way, shaping a targeted subset of bunches while leaving the remaining bunches unchanged. This experiment enables the delivery of shaped x-ray pulses to multiple undulator beamlines, with pulse properties tailored to specialized scientific applications.
△ Less
Submitted 2 April, 2024;
originally announced April 2024.
-
PWACG: Partial Wave Analysis Code Generator supporting Newton-conjugate gradient method
Authors:
Xiang Dong,
Yu-Chang Sun,
Chu-Cheng Pan,
Ao-Yan Cheng,
Ao-Bo Wang,
Hao Cai,
Kai Zhu
Abstract:
This paper introduces a novel Partial Wave Analysis Code Generator (PWACG) that automatically generates high-performance partial wave analysis codes. This is achieved by leveraging the JAX automatic differentiation library and the jinja2 template engine. The resulting code is constructed using the high-performance API of JAX, and includes support for the Newton's Conjugate Gradient optimization me…
▽ More
This paper introduces a novel Partial Wave Analysis Code Generator (PWACG) that automatically generates high-performance partial wave analysis codes. This is achieved by leveraging the JAX automatic differentiation library and the jinja2 template engine. The resulting code is constructed using the high-performance API of JAX, and includes support for the Newton's Conjugate Gradient optimization method, as well as the full utilization of parallel computing capabilities offered by GPUs. By harnessing these advanced computing techniques, PWACG demonstrates a significant advantage in efficiently identifying global optimal points compared to conventional partial wave analysis software packages.
△ Less
Submitted 14 March, 2024;
originally announced March 2024.
-
Topological Protection of Optical Skyrmions through Complex Media
Authors:
An Aloysius Wang,
Zimo Zhao,
Yifei Ma,
Yuxi Cai,
Tade Marozsak,
Binguo Chen,
Honghui He,
Lin Luo,
Martin J Booth,
Steve J Elston,
Stephen M Morris,
Chao He
Abstract:
Recent experimental realizations of optical Skyrmions through the techniques of structured light have opened the doors to a completely new way of representing data in electromagnetic fields, namely its topology. Apart from potentially enhancing the bandwidth of optical systems, the intrinsically discrete nature of the topological number allows Skyrmions to naturally interface with the digital worl…
▽ More
Recent experimental realizations of optical Skyrmions through the techniques of structured light have opened the doors to a completely new way of representing data in electromagnetic fields, namely its topology. Apart from potentially enhancing the bandwidth of optical systems, the intrinsically discrete nature of the topological number allows Skyrmions to naturally interface with the digital world. However, investigations into the topological protection of optical Skyrmions through various media remain limited to date. Here, we rigorously define the optical Skyrmion and establish a framework that can be used to analyze the effects of complex media on the topology of Skyrmion fields. Using this framework, we provide simple criteria for spatially varying retarders, diattenuators, depolarizers, and combinations of the former under which topological protection is guaranteed. We then present experimental results validating the robustness of the Skyrmion number against corrupting media and discuss ways of extending the optical Skyrmion to more general settings. We believe that the work presented in this paper provides a theoretical underpinning for the use of Skyrmions in practical applications ranging from optical communications to photonic computing.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Detecting Neutrinos from Supernova Bursts in PandaX-4T
Authors:
Binyu Pang,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Chen Cheng,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Yanlin Huang,
Junting Huang,
Zhou Huang,
Ruquan Hou
, et al. (71 additional authors not shown)
Abstract:
Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict…
▽ More
Neutrinos from core-collapse supernovae are essential for the understanding of neutrino physics and stellar evolution. The dual-phase xenon dark matter detectors can provide a way to track explosions of galactic supernovae by detecting neutrinos through coherent elastic neutrino-nucleus scatterings. In this study, a variation of progenitor masses as well as explosion models are assumed to predict the neutrino fluxes and spectra, which result in the number of expected neutrino events ranging from 6.6 to 13.7 at a distance of 10 kpc over a 10-second duration with negligible backgrounds at PandaX-4T. Two specialized triggering alarms for monitoring supernova burst neutrinos are built. The efficiency of detecting supernova explosions at various distances in the Milky Way is estimated. These alarms will be implemented in the real-time supernova monitoring system at PandaX-4T in the near future, providing the astronomical communities with supernova early warnings.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
Signal Response Model in PandaX-4T
Authors:
Yunyang Luo,
Zihao Bo,
Shibo Zhang,
Abdusalam Abdukerim,
Chen Cheng,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Yanlin Huang,
Zhou Huang
, et al. (66 additional authors not shown)
Abstract:
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as ga…
▽ More
PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.
△ Less
Submitted 14 June, 2024; v1 submitted 7 March, 2024;
originally announced March 2024.
-
Improved modeling of in-ice particle showers for IceCube event reconstruction
Authors:
R. Abbasi,
M. Ackermann,
J. Adams,
S. K. Agarwalla,
J. A. Aguilar,
M. Ahlers,
J. M. Alameddine,
N. M. Amin,
K. Andeen,
G. Anton,
C. Argüelles,
Y. Ashida,
S. Athanasiadou,
L. Ausborm,
S. N. Axani,
X. Bai,
A. Balagopal V.,
M. Baricevic,
S. W. Barwick,
S. Bash,
V. Basu,
R. Bay,
J. J. Beatty,
J. Becker Tjus,
J. Beise
, et al. (394 additional authors not shown)
Abstract:
The IceCube Neutrino Observatory relies on an array of photomultiplier tubes to detect Cherenkov light produced by charged particles in the South Pole ice. IceCube data analyses depend on an in-depth characterization of the glacial ice, and on novel approaches in event reconstruction that utilize fast approximations of photoelectron yields. Here, a more accurate model is derived for event reconstr…
▽ More
The IceCube Neutrino Observatory relies on an array of photomultiplier tubes to detect Cherenkov light produced by charged particles in the South Pole ice. IceCube data analyses depend on an in-depth characterization of the glacial ice, and on novel approaches in event reconstruction that utilize fast approximations of photoelectron yields. Here, a more accurate model is derived for event reconstruction that better captures our current knowledge of ice optical properties. When evaluated on a Monte Carlo simulation set, the median angular resolution for in-ice particle showers improves by over a factor of three compared to a reconstruction based on a simplified model of the ice. The most substantial improvement is obtained when including effects of birefringence due to the polycrystalline structure of the ice. When evaluated on data classified as particle showers in the high-energy starting events sample, a significantly improved description of the events is observed.
△ Less
Submitted 22 April, 2024; v1 submitted 4 March, 2024;
originally announced March 2024.
-
FPM-WSI: Fourier ptychographic whole slide imaging via feature-domain backdiffraction
Authors:
Shuhe Zhang,
Aiye Wang,
Jinghao Xu,
Tianci Feng,
Jinhua Zhou,
An Pan
Abstract:
Fourier ptychographic microscopy (FPM), characterized by high-throughput computational imaging, theoretically provides a cunning solution to the trade-off between spatial resolution and field of view (FOV), which has a promising prospect in the application of digital pathology. However, block reconstruction and then stitching has currently become an unavoidable procedure due to vignetting effects.…
▽ More
Fourier ptychographic microscopy (FPM), characterized by high-throughput computational imaging, theoretically provides a cunning solution to the trade-off between spatial resolution and field of view (FOV), which has a promising prospect in the application of digital pathology. However, block reconstruction and then stitching has currently become an unavoidable procedure due to vignetting effects. The stitched image tends to present color inconsistency in different image segments, or even stitching artifacts. In response, we reported a computational framework based on feature-domain backdiffraction to realize full-FOV, stitching-free FPM reconstruction. Different from conventional algorithms that establish the loss function in the image domain, our method formulates it in the feature domain, where effective information of images is extracted by a feature extractor to bypass the vignetting effect. The feature-domain error between predicted images based on estimation of model parameters and practically captured images is then digitally diffracted back through the optical system for complex amplitude reconstruction and aberration compensation. Through massive simulations and experiments, the method presents effective elimination of vignetting artifacts, and reduces the requirement of precise knowledge of illumination positions. We also found its great potential to recover the data with a lower overlapping rate of spectrum and to realize automatic blind-digital refocusing without a prior defocus distance.
△ Less
Submitted 28 February, 2024;
originally announced February 2024.
-
Attosecond X-ray Chronoscopy of Core-level Photoemission
Authors:
Jia-Bao Ji,
Zhaoheng Guo,
Taran Driver,
Cynthia S. Trevisan,
David Cesar,
Xinxin Cheng,
Joseph Duris,
Paris L. Franz,
James Glownia,
Xiaochun Gong,
Daniel Hammerland,
Meng Han,
Saijoscha Heck,
Matthias Hoffmann,
Andrei Kamalov,
Kirk A. Larsen,
Xiang Li,
Ming-Fu Lin,
Yuchen Liu,
C. William McCurdy,
Razib Obaid,
Jordan T. ONeal,
Thomas N. Rescigno,
River R. Robles,
Nicholas Sudar
, et al. (10 additional authors not shown)
Abstract:
Attosecond photoemission or photoionization delays are a unique probe of the structure and the electronic dynamics of matter. However, spectral congestion and spatial delocalization of valence electron wave functions set fundamental limits to the complexity of systems that can be studied and the information that can be retrieved, respectively. Using attosecond X-ray pulses from LCLS, we demonstrat…
▽ More
Attosecond photoemission or photoionization delays are a unique probe of the structure and the electronic dynamics of matter. However, spectral congestion and spatial delocalization of valence electron wave functions set fundamental limits to the complexity of systems that can be studied and the information that can be retrieved, respectively. Using attosecond X-ray pulses from LCLS, we demonstrate the key advantages of measuring core-level delays: the photoelectron spectra remain atom-like, the measurements become element specific and the observed scattering dynamics originate from a point-like source. We exploit these unique features to reveal the effects of electronegativity and symmetry on attosecond scattering dynamics by measuring the photoionization delays between N-1s and C-1s core shells of a series of aromatic azabenzene molecules. Remarkably, the delays systematically increase with the number of nitrogen atoms in the molecule and reveal multiple resonances. We identify two previously unknown mechanisms regulating the associated attosecond dynamics, namely the enhanced confinement of the trapped wavefunction with increasing electronegativity of the atoms and the decrease of the coupling strength among the photoemitted partial waves with increasing symmetry. This study demonstrates the unique opportunities opened by measurements of core-level photoionization delays for unravelling attosecond electron dynamics in complex matter.
△ Less
Submitted 8 April, 2024; v1 submitted 27 February, 2024;
originally announced February 2024.
-
Attosecond Delays in X-ray Molecular Ionization
Authors:
Taran Driver,
Miles Mountney,
Jun Wang,
Lisa Ortmann,
Andre Al-Haddad,
Nora Berrah,
Christoph Bostedt,
Elio G. Champenois,
Louis F. DiMauro,
Joseph Duris,
Douglas Garratt,
James M. Glownia,
Zhaoheng Guo,
Daniel Haxton,
Erik Isele,
Igor Ivanov,
Jiabao Ji,
Andrei Kamalov,
Siqi Li,
Ming-Fu Lin,
Jon P. Marangos,
Razib Obaid,
Jordan T. O'Neal,
Philipp Rosenberger,
Niranjan H. Shivaram
, et al. (12 additional authors not shown)
Abstract:
The photoelectric effect is not truly instantaneous, but exhibits attosecond delays that can reveal complex molecular dynamics. Sub-femtosecond duration light pulses provide the requisite tools to resolve the dynamics of photoionization. Accordingly, the past decade has produced a large volume of work on photoionization delays following single photon absorption of an extreme ultraviolet (XUV) phot…
▽ More
The photoelectric effect is not truly instantaneous, but exhibits attosecond delays that can reveal complex molecular dynamics. Sub-femtosecond duration light pulses provide the requisite tools to resolve the dynamics of photoionization. Accordingly, the past decade has produced a large volume of work on photoionization delays following single photon absorption of an extreme ultraviolet (XUV) photon. However, the measurement of time-resolved core-level photoionization remained out of reach. The required x-ray photon energies needed for core-level photoionization were not available with attosecond tabletop sources. We have now measured the x-ray photoemission delay of core-level electrons, and here report unexpectedly large delays, ranging up to 700 attoseconds in NO near the oxygen K-shell threshold. These measurements exploit attosecond soft x-ray pulses from a free-electron laser (XFEL) to scan across the entire region near the K-shell threshold. Furthermore, we find the delay spectrum is richly modulated, suggesting several contributions including transient trapping of the photoelectron due to shape resonances, collisions with the Auger-Meitner electron that is emitted in the rapid non-radiative relaxation of the molecule, and multi-electron scattering effects. The results demonstrate how x-ray attosecond experiments, supported by comprehensive theoretical modelling, can unravel the complex correlated dynamics of core-level photoionization.
△ Less
Submitted 20 February, 2024;
originally announced February 2024.
-
Active Disruption Avoidance and Trajectory Design for Tokamak Ramp-downs with Neural Differential Equations and Reinforcement Learning
Authors:
Allen M. Wang,
Oswin So,
Charles Dawson,
Darren T. Garnier,
Cristina Rea,
Chuchu Fan
Abstract:
The tokamak offers a promising path to fusion energy, but plasma disruptions pose a major economic risk, motivating considerable advances in disruption avoidance. This work develops a reinforcement learning approach to this problem by training a policy to safely ramp-down the plasma current while avoiding limits on a number of quantities correlated with disruptions. The policy training environment…
▽ More
The tokamak offers a promising path to fusion energy, but plasma disruptions pose a major economic risk, motivating considerable advances in disruption avoidance. This work develops a reinforcement learning approach to this problem by training a policy to safely ramp-down the plasma current while avoiding limits on a number of quantities correlated with disruptions. The policy training environment is a hybrid physics and machine learning model trained on simulations of the SPARC primary reference discharge (PRD) ramp-down, an upcoming burning plasma scenario which we use as a testbed. To address physics uncertainty and model inaccuracies, the simulation environment is massively parallelized on GPU with randomized physics parameters during policy training. The trained policy is then successfully transferred to a higher fidelity simulator where it successfully ramps down the plasma while avoiding user-specified disruptive limits. We also address the crucial issue of safety criticality by demonstrating that a constraint-conditioned policy can be used as a trajectory design assistant to design a library of feed-forward trajectories to handle different physics conditions and user settings. As a library of trajectories is more interpretable and verifiable offline, we argue such an approach is a promising path for leveraging the capabilities of reinforcement learning in the safety-critical context of burning plasma tokamaks. Finally, we demonstrate how the training environment can be a useful platform for other feed-forward optimization approaches by using an evolutionary algorithm to perform optimization of feed-forward trajectories that are robust to physics uncertainty
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
Weak-measurement-based pseudospin pointer: A cost-effective scheme for precision measurement
Authors:
Ling Ye,
Lan Luo,
An Wang,
Rongchun Ge,
Zhiyou Zhang
Abstract:
As an essential component of state-of-the-art quantum technologies, fast and efficient quantum measurements are in persistent demand over time. We present a proof-of-principle experiment on a new dimensionless pseudo-spin pointer based on weak measurement. In the context of optical parameter estimation, we demonstrate that the parametric distribution's moment is obtained experimentally by employin…
▽ More
As an essential component of state-of-the-art quantum technologies, fast and efficient quantum measurements are in persistent demand over time. We present a proof-of-principle experiment on a new dimensionless pseudo-spin pointer based on weak measurement. In the context of optical parameter estimation, we demonstrate that the parametric distribution's moment is obtained experimentally by employing the dimensionless pointer without measuring the distribution literally. In addition to the sheer liberation of experimental expense, the photon-countering-based pointer is well-calibrated for the detection of weak signals. We show that for signals $3$-$4$ orders of weaker in strength than the area-array camera method, an order of improvement in precision is achieved experimentally.
△ Less
Submitted 12 June, 2024; v1 submitted 3 February, 2024;
originally announced February 2024.
-
Experimental Demonstration of Attosecond Pump-Probe Spectroscopy with an X-ray Free-Electron Laser
Authors:
Zhaoheng Guo,
Taran Driver,
Sandra Beauvarlet,
David Cesar,
Joseph Duris,
Paris L. Franz,
Oliver Alexander,
Dorian Bohler,
Christoph Bostedt,
Vitali Averbukh,
Xinxin Cheng,
Louis F. DiMauro,
Gilles Doumy,
Ruaridh Forbes,
Oliver Gessner,
James M. Glownia,
Erik Isele,
Andrei Kamalov,
Kirk A. Larsen,
Siqi Li,
Xiang Li,
Ming-Fu Lin,
Gregory A. McCracken,
Razib Obaid,
Jordan T. ONeal
, et al. (25 additional authors not shown)
Abstract:
Pump-probe experiments with sub-femtosecond resolution are the key to understanding electronic dynamics in quantum systems. Here we demonstrate the generation and control of sub-femtosecond pulse pairs from a two-colour X-ray free-electron laser (XFEL). By measuring the delay between the two pulses with an angular streaking diagnostic, we characterise the group velocity of the XFEL and demonstrate…
▽ More
Pump-probe experiments with sub-femtosecond resolution are the key to understanding electronic dynamics in quantum systems. Here we demonstrate the generation and control of sub-femtosecond pulse pairs from a two-colour X-ray free-electron laser (XFEL). By measuring the delay between the two pulses with an angular streaking diagnostic, we characterise the group velocity of the XFEL and demonstrate control of the pulse delay down to 270 as. We demonstrate the application of this technique to a pump-probe measurement in core-excited para-aminophenol. These results demonstrate the ability to perform pump-probe experiments with sub-femtosecond resolution and atomic site specificity.
△ Less
Submitted 26 January, 2024;
originally announced January 2024.
-
A coronary artery phantom for task-based CT performance assessment and a comparative study of clinical CT, photon counting CT, and micro CT
Authors:
Jed D. Pack,
Paul Fitzgerald,
Stephen Araujo,
Ying Fan,
Grant Stevens,
Jonathan Gerdes,
Adam Wang,
Koen Nieman,
Ge Wang,
Bruno De Man
Abstract:
While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more…
▽ More
While drastic improvements in CT technology have occurred in the past 25 years, spatial resolution is one area where progress has been limited until recently. New photon counting CT systems, are capable of much better spatial resolution than their (energy integrating) predecessors. These improvements have the potential to improve the evaluation obstructive coronary artery disease by enabling more accurate delineation between calcified plaque and coronary vessel lumen. A new set of vessel phantoms has been designed and manufactured for quantifying this improvement. Comparisons are made between an existing clinical CT system, a prototype photon counting system, with images from a micro CT system being used as the gold standard. Scans were made of the same objects on all three systems. The resulting images were registered and the luminal cross section areas were compared. Luminal cross-sections near calcified plaques were reduced due to blooming, but this effect was much less pronounced in images from the prototype photon counting system as compared to the images from the clinical CT system.
△ Less
Submitted 8 January, 2024;
originally announced January 2024.
-
Improvement on the Linearity Response of PandaX-4T with new Photomultiplier Tubes Bases
Authors:
Lingyin Luo,
Deqing Fang,
Ke Han,
Di Huang,
Xiaofeng Shang,
Anqing Wang,
Qiuhong Wang,
Shaobo Wang,
Siguang Wang,
Xiang Xiao,
Binbin Yan,
Xiyu Yan
Abstract:
With the expanding reach of physics, xenon-based detectors such as PandaX-4T in the China Jinping Underground Laboratory aim to cover an energy range from sub-keV to multi-MeV. A linear response of the photomultiplier tubes (PMTs) is required for both scintillation and electroluminescence signals. Through a dedicated bench test, we investigated the cause of the non-linear response in the Hamamatsu…
▽ More
With the expanding reach of physics, xenon-based detectors such as PandaX-4T in the China Jinping Underground Laboratory aim to cover an energy range from sub-keV to multi-MeV. A linear response of the photomultiplier tubes (PMTs) is required for both scintillation and electroluminescence signals. Through a dedicated bench test, we investigated the cause of the non-linear response in the Hamamatsu R11410-23 PMTs used in PandaX-4T. The saturation and suppression of the PMT waveform observed during the commissioning of PandaX-4T were caused by the high-voltage divider base. The bench test data validated the de-saturation algorithm used in the PandaX-4T data analysis. We also confirmed the improvement in linearity of a new PMT base design, which will be used to upgrade the PMT readout system in PandaX-4T.
△ Less
Submitted 7 April, 2024; v1 submitted 30 December, 2023;
originally announced January 2024.
-
Waveform Simulation in PandaX-4T
Authors:
Jiafu Li,
Abdusalam Abdukerim,
Chen Cheng,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Yanlin Huang,
Zhou Huang,
Ruquan Hou
, et al. (66 additional authors not shown)
Abstract:
Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considera…
▽ More
Signal reconstruction through software processing is a crucial component of the background and signal models in the PandaX-4T experiment, which is a multi-tonne dark matter direct search experiment. The accuracy of signal reconstruction is influenced by various detector artifacts, including noise, dark count of photomultiplier, impurity photoionization in the detector, and other relevant considerations. In this study, we present a detailed description of a semi-data-driven approach designed to simulate the signal waveform. This work provides a reliable model for the efficiency and bias of the signal reconstruction in the data analysis of PandaX-4T. By comparing critical variables which relate to the temporal shape and hit pattern of the signals, we demonstrate a good agreement between the simulation and data.
△ Less
Submitted 21 May, 2024; v1 submitted 18 December, 2023;
originally announced December 2023.
-
Coronary Atherosclerotic Plaque Characterization with Photon-counting CT: a Simulation-based Feasibility Study
Authors:
Mengzhou Li,
Mingye Wu,
Jed Pack,
Pengwei Wu,
Bruno De Man,
Adam Wang,
Koen Nieman,
Ge Wang
Abstract:
Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities…
▽ More
Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on detectors made of CZT or CdTe materials, deep-silicon photon-counting detectors have unique performance characteristics and promise distinct imaging capabilities. In this work, we report a systematic simulation study of a deep-silicon PCCT scanner with a new clinically-relevant digital plaque phantom with realistic geometrical parameters and chemical compositions. This work investigates the effects of spatial resolution, noise, motion artifacts, radiation dose, and spectral characterization. Our simulation results suggest that the deep-silicon PCCT design provides adequate spatial resolution for visualizing a necrotic core and quantitation of key plaque features. Advanced denoising techniques and aggressive bowtie filter designs can keep image noise to acceptable levels at this resolution while keeping radiation dose comparable to that of a conventional CT scan. The ultrahigh resolution of PCCT also means an elevated sensitivity to motion artifacts. It is found that a tolerance of less than 0.4 mm residual movement range requires the application of accurate motion correction methods for best plaque imaging quality with PCCT.
△ Less
Submitted 3 December, 2023;
originally announced December 2023.
-
A universal optical modulator for synthetic topologically tuneable structured matter
Authors:
Chao He,
Binguo Chen,
Zipei Song,
Zimo Zhao,
Yifei Ma,
Honghui He,
Lin Luo,
Tade Marozsak,
An Wang,
Rui Xu,
Peixiang Huang,
Xuke Qiu,
Bangshan Sun,
Jiahe Cui,
Yuxi Cai,
Yun Zhang,
Patrick Salter,
Julian AJ Fells,
Ben Dai,
Shaoxiong Liu,
Limei Guo,
Hui Ma,
Steve J Elston,
Qiwen Zhan,
Chengwei Qiu
, et al. (3 additional authors not shown)
Abstract:
Topologically structured matter, such as metasurfaces and metamaterials, have given rise to impressive photonic functionality, fuelling diverse applications from microscopy and holography to encryption and communication. Presently these solutions are limited by their largely static nature and preset functionality, hindering applications that demand dynamic photonic systems with reconfigurable topo…
▽ More
Topologically structured matter, such as metasurfaces and metamaterials, have given rise to impressive photonic functionality, fuelling diverse applications from microscopy and holography to encryption and communication. Presently these solutions are limited by their largely static nature and preset functionality, hindering applications that demand dynamic photonic systems with reconfigurable topologies. Here we demonstrate a universal optical modulator that implements topologically tuneable structured matter as virtual pixels derived from cascading low functionality tuneable devices, altering the paradigm of phase and amplitude control to encompass arbitrary spatially varying retarders in a synthetic structured matter device. Our approach opens unprecedented functionality that is user-defined with high flexibility, allowing our synthetic structured matter to act as an information carrier, beam generator, analyser, and corrector, opening an exciting path to tuneable topologies of light and matter.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
-
Lithium-ion battery performance model including solvent segregation effects
Authors:
Ruihe Li,
Simon O'Kane,
Andrew Wang,
Taeho Jung,
Niall Kirkaldy,
Monica Marinescu,
Charles W. Monroe,
Gregory J. Offer
Abstract:
A model of a lithium-ion battery containing a cosolvent electrolyte is developed and implemented within the open-source PyBaMM platform. Lithium-ion electrolytes are essential to battery operation and normally contain at least two solvents to satisfy performance requirements. The widely used Doyle-Fuller-Newman battery model assumes that the electrolyte comprises a salt dissolved in a single effec…
▽ More
A model of a lithium-ion battery containing a cosolvent electrolyte is developed and implemented within the open-source PyBaMM platform. Lithium-ion electrolytes are essential to battery operation and normally contain at least two solvents to satisfy performance requirements. The widely used Doyle-Fuller-Newman battery model assumes that the electrolyte comprises a salt dissolved in a single effective solvent, however. This single-solvent approximation has been disproved experimentally and may hinder accurate battery modelling. Here, we present a two-solvent model that resolves the transport of ethylene carbonate (EC) and lithium salt in a background linear carbonate. EC concentration polarization opposes that of Li+ during cycling, affecting local electrolyte properties and cell-level overpotentials. Concentration gradients of Li+ can be affected by cross-diffusion, whereby EC gradients enhance or impede salt flux. A rationally parametrized model that includes EC transport predicts 6% more power loss at 4.5C discharge and ~0.32% more capacity loss after a thousand 1C cycles than its single-solvent equivalent. This work provides a tool to model more transport behaviour in the electrolyte that may affect degradation and enables the transfer of microscopic knowledge about solvation structure-dependent performance to the macroscale.
△ Less
Submitted 9 November, 2023;
originally announced November 2023.
-
Sub-5-nm Ultra-thin In$_2$O$_3$ Transistors for High-Performance and Low-Power Electronic Applications
Authors:
Linqiang Xu,
Lianqiang Xu,
Jun Lan,
Yida Li,
Qiuhui Li,
Aili Wang,
Ying Guo,
Yee Sin Ang,
Ruge Quhe,
Jing Lu
Abstract:
Ultra-thin (UT) oxide semiconductors are promising candidates for back-end-of-line (BEOL) compatible transistors and monolithic three-dimensional integration. Experimentally, UT indium oxide (In$_2$O$_3$) field-effect transistors (FETs) with thicknesses down to 0.4 nm exhibits extremely high drain current (10000 $μ$A/$μ$m) and transconductance (4000 $μ$S/$μ$m). Here, we employ the ab initio quantu…
▽ More
Ultra-thin (UT) oxide semiconductors are promising candidates for back-end-of-line (BEOL) compatible transistors and monolithic three-dimensional integration. Experimentally, UT indium oxide (In$_2$O$_3$) field-effect transistors (FETs) with thicknesses down to 0.4 nm exhibits extremely high drain current (10000 $μ$A/$μ$m) and transconductance (4000 $μ$S/$μ$m). Here, we employ the ab initio quantum transport simulation to investigate the performance limit of sub-5-nm gate length (Lg) UT In$_2$O$_3$ FET. Based on the International Technology Roadmap for Semiconductors (ITRS) criteria for high-performance (HP) devices, the scaling limit of UT In$_2$O$_3$ FETs can reach 2 nm in terms of on-state current, delay time, and power dissipation. The wide bandgap nature of UT In$_2$O$_3$ (3.15 eV) renders it a suitable candidate for ITRS low-power (LP) electronics with Lg down to 3 nm. Both the HP and LP UT In$_2$O$_3$ FETs exhibit superior energy-delay products as compared to other common 2D semiconductors such as monolayer MoS2 and MoTe2. Our study unveils the immense promise of UT In$_2$O$_3$ for both HP and LP device applications.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Physical-layer key distribution using synchronous complex dynamics of DBR semiconductor lasers
Authors:
Anbang Wang,
Yicheng Du,
Qingtian Li,
Longsheng Wang,
Zhiwei Jia,
Yuwen Qin,
Yuncai Wang
Abstract:
Common-signal-induced synchronization of semiconductor lasers with optical feedback inspired a promising physical key distribution with information-theoretic security and potential in high rate. A significant challenge is the requirement to shorten the synchronization recovery time for increasing key rate without sacrificing operation parameter space for security. Here, open-loop synchronization o…
▽ More
Common-signal-induced synchronization of semiconductor lasers with optical feedback inspired a promising physical key distribution with information-theoretic security and potential in high rate. A significant challenge is the requirement to shorten the synchronization recovery time for increasing key rate without sacrificing operation parameter space for security. Here, open-loop synchronization of wavelength-tunable multi-section distributed Bragg reflector (DBR) lasers is proposed as a solution for physical-layer key distribution. Experiments show that the synchronization is sensitive to two operation parameters, i.e., currents of grating section and phase section. Furthermore, fast wavelength-shift keying synchronization can be achieved by direct modulation on one of the two currents. The synchronization recovery time is shortened by one order of magnitude compared to close-loop synchronization. An experimental implementation is demonstrated with a final key rate of 5.98 Mbit/s over 160 km optical fiber distance. It is thus believed that fast-tunable multi-section semiconductor lasers opens a new avenue of high-rate physical-layer key distribution using laser synchronization.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
Hybridizing Physics and Neural ODEs for Predicting Plasma Inductance Dynamics in Tokamak Fusion Reactors
Authors:
Allen M. Wang,
Darren T. Garnier,
Cristina Rea
Abstract:
While fusion reactors known as tokamaks hold promise as a firm energy source, advances in plasma control, and handling of events where control of plasmas is lost, are needed for them to be economical. A significant bottleneck towards applying more advanced control algorithms is the need for better plasma simulation, where both physics-based and data-driven approaches currently fall short. The form…
▽ More
While fusion reactors known as tokamaks hold promise as a firm energy source, advances in plasma control, and handling of events where control of plasmas is lost, are needed for them to be economical. A significant bottleneck towards applying more advanced control algorithms is the need for better plasma simulation, where both physics-based and data-driven approaches currently fall short. The former is bottle-necked by both computational cost and the difficulty of modelling plasmas, and the latter is bottle-necked by the relative paucity of data. To address this issue, this work applies the neural ordinary differential equations (ODE) framework to the problem of predicting a subset of plasma dynamics, namely the coupled plasma current and internal inductance dynamics. As the neural ODE framework allows for the natural inclusion of physics-based inductive biases, we train both physics-based and neural network models on data from the Alcator C-Mod fusion reactor and find that a model that combines physics-based equations with a neural ODE performs better than both existing physics-motivated ODEs and a pure neural ODE model.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
Event Generation and Consistence Test for Physics with Sliced Wasserstein Distance
Authors:
Chu-Cheng Pan,
Xiang Dong,
Yu-Chang Sun,
Ao-Yan Cheng,
Ao-Bo Wang,
Yu-Xuan Hu,
Hao Cai
Abstract:
In the field of modern high-energy physics research, there is a growing emphasis on utilizing deep learning techniques to optimize event simulation, thereby expanding the statistical sample size for more accurate physical analysis. Traditional simulation methods often encounter challenges when dealing with complex physical processes and high-dimensional data distributions, resulting in slow perfor…
▽ More
In the field of modern high-energy physics research, there is a growing emphasis on utilizing deep learning techniques to optimize event simulation, thereby expanding the statistical sample size for more accurate physical analysis. Traditional simulation methods often encounter challenges when dealing with complex physical processes and high-dimensional data distributions, resulting in slow performance. To overcome these limitations, we propose a solution based on deep learning with the sliced Wasserstein distance as the loss function. Our method shows its ability on high precision and large-scale simulations, and demonstrates its effectiveness in handling complex physical processes. By employing an advanced transformer learning architecture, we initiate the learning process from a Monte Carlo sample, and generate high-dimensional data while preserving all original distribution features. The generated data samples have passed the consistence test, that is developed to calculate the confidence of the high-dimentional distributions of the generated data samples through permutation tests. This fast simulation strategy, enabled by deep learning, holds significant potential not only for increasing sample sizes and reducing statistical uncertainties but also for applications in numerical integration, which is crucial in partial wave analysis, high-precision sample checks, and other related fields. It opens up new possibilities for improving event simulation in high-energy physics research.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
Low Cross-Talk Optical Addressing of Trapped-Ion Qubits Using a Novel Integrated Photonic Chip
Authors:
A. S. Sotirova,
B. Sun,
J. D. Leppard,
A. Wang,
M. Wang,
A. Vazquez-Brennan,
D. P. Nadlinger,
S. Moser,
A. Jesacher,
C. He,
F. Pokorny,
M. J. Booth,
C. J. Ballance
Abstract:
Individual optical addressing in chains of trapped atomic ions requires generation of many small, closely spaced beams with low cross-talk. Furthermore, implementing parallel operations necessitates phase, frequency, and amplitude control of each individual beam. Here we present a scalable method for achieving all of these capabilities using a novel integrated photonic chip coupled to a network of…
▽ More
Individual optical addressing in chains of trapped atomic ions requires generation of many small, closely spaced beams with low cross-talk. Furthermore, implementing parallel operations necessitates phase, frequency, and amplitude control of each individual beam. Here we present a scalable method for achieving all of these capabilities using a novel integrated photonic chip coupled to a network of optical fibre components. The chip design results in very low cross-talk between neighbouring channels even at the micrometre-scale spacing by implementing a very high refractive index contrast between the channel core and cladding. Furthermore, the photonic chip manufacturing procedure is highly flexible, allowing for the creation of devices with an arbitrary number of channels as well as non-uniform channel spacing at the chip output. We present the system used to integrate the chip within our ion trap apparatus and characterise the performance of the full individual addressing setup using a single trapped ion as a light-field sensor. Our measurements showed intensity cross-talk below $10^{-3}$ across the chip, with minimum observed cross-talk as low as $O\left(10^{-5}\right)$.
△ Less
Submitted 20 October, 2023;
originally announced October 2023.
-
Metal-Optic Nanophotonic Modulators in Standard CMOS Technology
Authors:
Mohamed ElKabbash,
Sivan Trajtenberg-Mills,
Isaac Harris,
Saumil Bandyopadhyay,
Mohamed I Ibrahim,
Archer Wang,
Xibi Chen,
Cole Brabec,
Hasan Z. Yildiz,
Ruonan Han,
Dirk Englund
Abstract:
Integrating nanophotonics with electronics promises revolutionary applications, from LiDAR to holographic displays. Although silicon photonics is maturing, realizing active nanophotonics in the ubiquitous bulk CMOS processes remains challenging. We introduce a fabless approach to embed active nanophotonics in bulk CMOS by co-designing the back-end-of-line metal layers for optical functionality. Us…
▽ More
Integrating nanophotonics with electronics promises revolutionary applications, from LiDAR to holographic displays. Although silicon photonics is maturing, realizing active nanophotonics in the ubiquitous bulk CMOS processes remains challenging. We introduce a fabless approach to embed active nanophotonics in bulk CMOS by co-designing the back-end-of-line metal layers for optical functionality. Using a 65nm CMOS process, we create plasmonic liquid crystal modulators with switching speeds 100x faster than commercial technologies. This zero-change nanophotonics method could equip mass-produced chips with optical communications, sensing and imaging. Embedding nanophotonics in the dominant electronics platform democratizes nanofabrication, spawning technologies from chip-scale LiDAR to holographic light-field displays.
△ Less
Submitted 16 November, 2023; v1 submitted 6 October, 2023;
originally announced October 2023.
-
Simulation study of BESIII with stitched CMOS pixel detector using ACTS
Authors:
Yi Liu,
Xiaocong Ai,
Guangyan Xiao,
Yaxuan Li,
Linghui Wu,
Liangliang Wang,
Jianing Dong,
Mingyi Dong,
Qinglin Geng,
Min Luo,
Yan Niu,
Anqing Wang,
Chenxu Wang,
Meng Wang,
Lei Zhang,
Liang Zhang,
Ruikai Zhang,
Yao Zhang,
Minggang Zhao,
Yang Zhou
Abstract:
Reconstruction of tracks of charged particles with high precision is very crucial for HEP experiments to achieve their physics goals. As the tracking detector of BESIII experiment, the BESIII drift chamber has suffered from aging effects resulting in degraded tracking performance after operation for about 15 years. To preserve and enhance the tracking performance of BESIII, one of the proposals is…
▽ More
Reconstruction of tracks of charged particles with high precision is very crucial for HEP experiments to achieve their physics goals. As the tracking detector of BESIII experiment, the BESIII drift chamber has suffered from aging effects resulting in degraded tracking performance after operation for about 15 years. To preserve and enhance the tracking performance of BESIII, one of the proposals is to add one layer of thin CMOS pixel sensor in cylindrical shape based on the state-of-the-art stitching technology, between the beam pipe and the drift chamber. The improvement of tracking performance of BESIII with such an additional pixel detector compared to that with only the existing drift chamber is studied using the modern common tracking software ACTS, which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high energy physics and nuclear physics experiments.
△ Less
Submitted 5 September, 2023;
originally announced September 2023.
-
Sub-Volt High-Speed Silicon MOSCAP Microring Modulator Driven by High Mobility Conductive Oxide
Authors:
Wei-Che Hsu,
Nabila Nujhat,
Benjamin Kupp,
John F. Conley Jr,
Haisheng Rong,
Ranjeet Kumar,
Alan X. Wang
Abstract:
Low driving voltage (Vpp), high-speed silicon microring modulator plays a critical role in energy-efficient optical interconnect and optical computing systems owing to its ultra-compact footprint and capability for on-chip wavelength-division multiplexing. However, existing silicon microring modulators usually require more than 2 V of Vpp, which is limited by the relatively weak plasma dispersion…
▽ More
Low driving voltage (Vpp), high-speed silicon microring modulator plays a critical role in energy-efficient optical interconnect and optical computing systems owing to its ultra-compact footprint and capability for on-chip wavelength-division multiplexing. However, existing silicon microring modulators usually require more than 2 V of Vpp, which is limited by the relatively weak plasma dispersion effect of silicon and the small capacitance density of the reversed PN-junction. Here we present a highly efficient metal-oxide semiconductor capacitor (MOSCAP) microring modulator through heterogeneous integration between silicon photonics and titanium-doped indium oxide, which is a high-mobility transparent conductive oxide (TCO) material with a strong plasma dispersion effect. The device is co-fabricated by Intel's photonics fab and TCO patterning processes at Oregon State University, which exhibits a high electro-optic modulation efficiency of 117 pm/V with a low VpiL of 0.12 Vcm, and consequently can be driven by an extremely low Vpp of 0.8 V. At a 11 GHz modulation bandwidth where the modulator is limited by the high parasitic capacitance, we obtained 25 Gb/s clear eye diagrams with energy efficiency of 53 fJ/bit and demonstrated 35 Gb/s open eyes with a higher driving voltage. Further optimization of the device is expected to increase the modulation bandwidth up to 52 GHz that can encode data at 100 Gb/s for next-generation, energy-efficient optical communication and computation with sub-volt driving voltage without using any high voltage swing amplifier.
△ Less
Submitted 30 August, 2023;
originally announced August 2023.
-
Frequency-comb-linearized, widely tunable lasers for coherent ranging
Authors:
Baoqi Shi,
Yi-Han Luo,
Wei Sun,
Yue Hu,
Jinbao Long,
Xue Bai,
Anting Wang,
Junqiu Liu
Abstract:
Tunable lasers, with the ability to continuously adjust their emission wavelengths, have found widespread applications across various fields such as biomedical imaging, coherent ranging, optical communications and spectroscopy. In these applications, a wide chirp range is advantageous for large spectral coverage and high frequency resolution. Besides, the frequency accuracy and precision also depe…
▽ More
Tunable lasers, with the ability to continuously adjust their emission wavelengths, have found widespread applications across various fields such as biomedical imaging, coherent ranging, optical communications and spectroscopy. In these applications, a wide chirp range is advantageous for large spectral coverage and high frequency resolution. Besides, the frequency accuracy and precision also depend critically on the chirp linearity of the laser. While extensive efforts have been made on the development of many kinds of frequency-agile, widely tunable, narrow-linewidth lasers, wideband yet precise methods to characterize and to linearize laser chirp dynamics are also demanded. Here we present an approach to characterize laser chirp dynamics using an optical frequency comb. The instantaneous laser frequency is tracked over terahertz bandwidth with 1 MHz interval. Using this approach we calibrate the chirp performance of twelve tunable lasers from Toptica, Santec, New Focus, EXFO and NKT that are commonly used in fiber optics and integrated photonics. In addition, with acquired knowledge on laser chirp dynamics, we demonstrate a simple frequency-linearization scheme that enables coherent ranging without any optical or electronic linearization units. Our approach not only presents a novel wideband, high-resolution laser spectroscopy, but is also critical for sensing applications with ever-increasing requirements on performance.
△ Less
Submitted 30 August, 2023;
originally announced August 2023.
-
A reconfigurable multiple-format coherent-dual-band signal generator based on a single optoelectronic oscillation cavity
Authors:
Yibei Wang,
Yalan Wang,
Hongyi Wang,
Xiaotong Liu,
Hong Chen,
Jin Zhang,
Dongyu Li,
Dangwei Wang,
Anle Wang
Abstract:
An optoelectronic oscillation method with reconfigurable multiple formats for simultaneous generation of coherent dual-band signals is proposed and experimentally demonstrated. By introducing a compatible filtering mechanism based on stimulated Brillouin scattering (SBS) effect into a typical Phase-shifted grating Bragg fiber (PS-FBG) notch filtering cavity, dual mode-selection mechanisms which ha…
▽ More
An optoelectronic oscillation method with reconfigurable multiple formats for simultaneous generation of coherent dual-band signals is proposed and experimentally demonstrated. By introducing a compatible filtering mechanism based on stimulated Brillouin scattering (SBS) effect into a typical Phase-shifted grating Bragg fiber (PS-FBG) notch filtering cavity, dual mode-selection mechanisms which have independent frequency and time tuning mechanism can be constructed. By regulating three controllers, the proposed scheme can work in different states, named mode 1, mode 2 and mode 3. At mode 1 state, a dual single-frequency hopping signals is achieved with 50 ns hopping speed and flexible central frequency and pulse duration ratio. The mode 2 state is realized by applying the Fourier domain mode-locked (FDML) technology into the proposed optoelectrical oscillator, in which dual coherent pulsed single-frequency signal and broadband signal is generated simultaneously. The adjustability of the time duration of the single-frequency signal and the bandwidth of the broadband signal are shown and discussed. The mode 3 state is a dual broadband signal generator which is realized by injecting a triangular wave into the signal laser. The detection performance of the generated broadband signals has also been evaluated by the pulse compression and the phase noise figure. The proposed method may provide a multifunctional radar system signal generator based on the simply external controllers, which can realize low-phase-noise or multifunctional detection with high resolution imaging ability, especially in a complex interference environment.
△ Less
Submitted 6 August, 2023;
originally announced August 2023.
-
MyoFold: rapid Myocardial tissue and movement quantification via a highly Folded sequence
Authors:
Rui Guo,
Yingwei Fan,
Bowei Liu,
Xiaofeng Qian,
Jiahuan Dai,
Dongyue Si,
Yuanyuan Wang,
Ancong Wang,
Xiaoying Tang,
Haiyan Ding
Abstract:
Purpose: To develop and evaluate a cardiovascular magnetic resonance sequence (MyoFold) for rapid myocardial tissue and movement characterization. Method: MyoFold sequentially performs joint T1/T2 mapping and cine for one left-ventricle slice within a breathing-holding of 12 heartbeats. MyoFold uses balanced Steady-State-Free-Precession (bSSFP) with 2-fold acceleration for data readout and adopts…
▽ More
Purpose: To develop and evaluate a cardiovascular magnetic resonance sequence (MyoFold) for rapid myocardial tissue and movement characterization. Method: MyoFold sequentially performs joint T1/T2 mapping and cine for one left-ventricle slice within a breathing-holding of 12 heartbeats. MyoFold uses balanced Steady-State-Free-Precession (bSSFP) with 2-fold acceleration for data readout and adopts an electrocardiogram (ECG) to synchronize the cardiac cycle. MyoFold first acquires six single-shot inversion-recovery images at the diastole of the first six heartbeats. For joint T1/T2 mapping, T2 preparation (T2-prep) adds different T2 weightings to the last three images. On the remaining six heartbeats, segmented bSSFP is continuously performed for each cardiac phase for cine. We build a neural network and trained it using the numerical simulation of MyoFold for T1 and T2 calculations. MyoFold was validated through phantom and in-vivo experiments and compared to MOLLI, SASHA, T2-prep bSSFP, and convention cine. Results: MyoFold phantom T1 had a 10% overestimation while MyoFold T2 had high accuracy. MyoFold in-vivo T1 had comparable accuracy to that of SASHA and precision to that of MOLLI. MyoFold had good agreement with T2-prep bSSFP in myocardium T2 measurement. There was no difference in the myocardium thickness measurement between the MyoFold cine and convention cine. Conclusion: MyoFold can simultaneously quantify myocardial tissue and movement, with accuracy and precision comparable to dedicated sequences, saving three-fold scan time.
△ Less
Submitted 16 July, 2023;
originally announced July 2023.
-
Femtosecond laser induced creation of G and W-centers in silicon-on-insulator substrates
Authors:
Hugo Quard,
Mario Khoury,
Andong Wang,
Tobias Herzig,
Jan Meijer,
Sebastian Pezzagna,
Sébastien Cueff,
David Grojo,
Marco Abbarchi,
Hai Son Nguyen,
Nicolas Chauvin,
Thomas Wood
Abstract:
The creation of fluorescent defects in silicon is a key stepping stone towards assuring the integration perspectives of quantum photonic devices into existing technologies. Here we demonstrate the creation, by femtosecond laser annealing, of W and G-centers in commercial silicon on insulator (SOI) previously implanted with 12C+ ions. Their quality is comparable to that found for the same emitters…
▽ More
The creation of fluorescent defects in silicon is a key stepping stone towards assuring the integration perspectives of quantum photonic devices into existing technologies. Here we demonstrate the creation, by femtosecond laser annealing, of W and G-centers in commercial silicon on insulator (SOI) previously implanted with 12C+ ions. Their quality is comparable to that found for the same emitters obtained with conventional implant processes; as quantified by the photoluminescence radiative lifetime, the broadening of their zero-phonon line (ZPL) and the evolution of these quantities with temperature. In addition to this, we show that both defects can be created without carbon implantation and that we can erase the G-centers by annealing while enhancing the W-centers' emission. These demonstrations are relevant to the deterministic and operando generation of quantum emitters in silicon.
△ Less
Submitted 7 April, 2023;
originally announced April 2023.
-
The New Small Wheel electronics
Authors:
G. Iakovidis,
L. Levinson,
Y. Afik,
C. Alexa,
T. Alexopoulos,
J. Ameel,
D. Amidei,
D. Antrim,
A. Badea,
C. Bakalis,
H. Boterenbrood,
R. S. Brener,
S. Chan,
J. Chapman,
G. Chatzianastasiou,
H. Chen,
M. C. Chu,
R. M. Coliban,
T. Costa de Paiva,
G. de Geronimo,
R. Edgar,
N. Felt,
S. Francescato,
M. Franklin,
T. Geralis
, et al. (77 additional authors not shown)
Abstract:
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector te…
▽ More
The increase in luminosity, and consequent higher backgrounds, of the LHC upgrades require improved rejection of fake tracks in the forward region of the ATLAS Muon Spectrometer. The New Small Wheel upgrade of the Muon Spectrometer aims to reduce the large background of fake triggers from track segments that are not originated from the interaction point. The New Small Wheel employs two detector technologies, the resistive strip Micromegas detectors and the "small" Thin Gap Chambers, with a total of 2.45 Million electrodes to be sensed. The two technologies require the design of a complex electronics system given that it consists of two different detector technologies and is required to provide both precision readout and a fast trigger. It will operate in a high background radiation region up to about 20 kHz/cm$^{2}$ at the expected HL-LHC luminosity of $\mathcal{L}$=7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. The architecture of the system is strongly defined by the GBTx data aggregation ASIC, the newly-introduced FELIX data router and the software based data handler of the ATLAS detector. The electronics complex of this new detector was designed and developed in the last ten years and consists of multiple radiation tolerant Application Specific Integrated Circuits, multiple front-end boards, dense boards with FPGA's and purpose-built Trigger Processor boards within the ATCA standard. The New Small Wheel has been installed in 2021 and is undergoing integration within ATLAS for LHC Run 3. It should operate through the end of Run 4 (December 2032). In this manuscript, the overall design of the New Small Wheel electronics is presented.
△ Less
Submitted 25 May, 2023; v1 submitted 22 March, 2023;
originally announced March 2023.
-
Developing a single phase liquid argon detector with SiPM readout
Authors:
L. Wang,
Y. Lei,
T. A. Wang,
C. Guo,
K. K. Zhao,
X. H. Liang,
S. B. Wang,
Y. D. Chen
Abstract:
Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over traditional PMT. In this paper, we developed a single-phase liquid argon detector using eight 1 $\times$1 inch$^2$ Hamamatsu S14161-6050HS 4$\times$4 SiPM arrays.…
▽ More
Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over traditional PMT. In this paper, we developed a single-phase liquid argon detector using eight 1 $\times$1 inch$^2$ Hamamatsu S14161-6050HS 4$\times$4 SiPM arrays. The directly measured light yield is 25.7 $\pm$ 1.6 photo-electrons per keV, which corresponds to 12.8 $\pm$ 0.8 photo-electrons primarily generated by the argon scintillation. The rest is contributed by the cross-talk and after-pulse of SiPM. In addition, we provide an experimental method to estimate the effect of crosstalk and afterpulse on light yield using dark noise data. Finally, we quantitatively give the relationship between the light yield and the decay time of the slow component of a liquid argon detector.
△ Less
Submitted 1 January, 2023; v1 submitted 26 December, 2022;
originally announced December 2022.
-
A new bound on the electron's electric dipole moment
Authors:
Tanya S. Roussy,
Luke Caldwell,
Trevor Wright,
William B. Cairncross,
Yuval Shagam,
Kia Boon Ng,
Noah Schlossberger,
Sun Yool Park,
Anzhou Wang,
Jun Ye,
Eric A. Cornell
Abstract:
The Standard Model cannot explain the dominance of matter over anti-matter in our universe. This imbalance indicates undiscovered physics that violates combined CP symmetry. Many extensions to the Standard Model seek to explain the imbalance by predicting the existence of new particles. Vacuum fluctuations of the fields associated with these new particles can interact with known particles and make…
▽ More
The Standard Model cannot explain the dominance of matter over anti-matter in our universe. This imbalance indicates undiscovered physics that violates combined CP symmetry. Many extensions to the Standard Model seek to explain the imbalance by predicting the existence of new particles. Vacuum fluctuations of the fields associated with these new particles can interact with known particles and make small modifications to their properties; for example, particles which violate CP symmetry will induce an electric dipole moment of the electron (eEDM). The size of the induced eEDM is dependent on the masses of the new particles and their coupling to the Standard Model. To date, no eEDM has been detected, but increasingly precise measurements probe new physics with higher masses and weaker couplings. Here we present the most precise measurement yet of the eEDM using electrons confined inside molecular ions, subjected to a huge intra-molecular electric field, and evolving coherently for up to 3 s. Our result is consistent with zero and improves on the previous best upper bound by a factor $\sim2.4$. Our sensitivity to $10^{-19}$ eV shifts in molecular ions provides constraints on broad classes of new physics above $10^{13}$ eV, well beyond the direct reach of the LHC or any other near- or medium-term particle collider.
△ Less
Submitted 27 December, 2022; v1 submitted 22 December, 2022;
originally announced December 2022.
-
Systematic and statistical uncertainty evaluation of the HfF$^+$ electron electric dipole moment experiment
Authors:
Luke Caldwell,
Tanya S. Roussy,
Trevor Wright,
William B. Cairncross,
Yuval Shagam,
Kia Boon Ng,
Noah Schlossberger,
Sun Yool Park,
Anzhou Wang,
Jun Ye,
Eric A. Cornell
Abstract:
We have completed a new precision measurement of the electron's electric dipole moment using trapped HfF$^+$ in rotating bias fields. We report on the accuracy evaluation of this measurement, describing the mechanisms behind our systematic shifts. Our systematic uncertainty is reduced by a factor of 30 compared to the first generation of this measurement. Our combined statistical and systematic ac…
▽ More
We have completed a new precision measurement of the electron's electric dipole moment using trapped HfF$^+$ in rotating bias fields. We report on the accuracy evaluation of this measurement, describing the mechanisms behind our systematic shifts. Our systematic uncertainty is reduced by a factor of 30 compared to the first generation of this measurement. Our combined statistical and systematic accuracy is improved by a factor of 2 relative to any previous measurement.
△ Less
Submitted 22 December, 2022; v1 submitted 22 December, 2022;
originally announced December 2022.
-
Reactor neutrino physics potentials of cryogenic pure-CsI crystal
Authors:
L. Wang,
G. d. Li,
Z. Y. Yu,
X. H. Liang,
T. A. Wang,
F. Liu,
X. L. Sun,
C. Guo,
X. Zhang,
L. Yu,
Y. D. Chen
Abstract:
This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with cryogenic front-end electronics. Benefiting the light yield enhancement of pure-CsI at low temperatures and the high photon detection efficiency of SiPM, a light y…
▽ More
This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with cryogenic front-end electronics. Benefiting the light yield enhancement of pure-CsI at low temperatures and the high photon detection efficiency of SiPM, a light yield of 30.1 photoelectrons per keV energy deposit was obtained for X-rays and $γ$-rays with energies from 5.9~keV to 59.6~keV. Instrumental and physical effects in the light yield measurement are carefully analyzed. This is the first stable cryogenic operation of kg-scale pure-CsI crystal readout by SiPM arrays at liquid nitrogen temperatures for several days. The world-leading light yield opens a door for the usage of pure-CsI crystal in several fields, particularly in detecting the coherent elastic neutrino-nucleus scattering of reactor neutrinos. The potential of using pure-CsI crystals in neutrino physics is discussed in the paper.
△ Less
Submitted 16 April, 2024; v1 submitted 22 December, 2022;
originally announced December 2022.
-
Multi-Energy Blended CBCT Spectral Imaging Using a Spectral Modulator with Flying Focal Spot (SMFFS)
Authors:
Yifan Deng,
Hao Zhou,
Zhilei Wang,
Adam S. Wang,
Hewei Gao
Abstract:
Conventional cone-beam CT (CBCT) can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. In this work, we present the first attempt to develop a stationary spectral modulator with flying focal spot (SMFFS) technology as a promising, low-cost approach to accurately solving the X-ray scattering problem…
▽ More
Conventional cone-beam CT (CBCT) can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. In this work, we present the first attempt to develop a stationary spectral modulator with flying focal spot (SMFFS) technology as a promising, low-cost approach to accurately solving the X-ray scattering problem and physically enabling spectral imaging in a unified framework. To deal with the intertwined scatter-spectral challenge, we propose a novel scatter-decoupled material decomposition (SDMD) method for SMFFS based on a hypothesis of scatter similarity. Monte Carlo simulations of a pure-water cylinder phantom with different focal spot deflections show that focal spot deflections within a range of ~2 mm share quite similar scatter distributions overall. Numerical simulations using a clinical abdominal CT dataset demonstrate that SMFFS with SDMD method can achieve better material decomposition and CT number accuracy with less artifacts. Physics experiments on a tabletop CBCT system using a Gammex multi-energy CT phantom an anthropomorphic chest phantom, are carried out to demonstrate the feasibility of CBCT spectral imaging with SMFFS. For the chest phantom, the root mean square error (RMSE) in selected regions of interest (ROIs) of virtual monochromatic image (VMI) at 70 keV is 11.8 HU for SMFFS CB scan, and 14.5 and 437.6 HU for sequential 80/140 kVp (DKV) CB scan with and without scatter correction, respectively. Also, the non-uniformity among selected regions is 14.1 HU for SMFFS CB scan, and 59.4 and 184.0 HU for the DKV CB scan with and without a traditional scatter correction method, respectively. Our preliminary results show that SMFFS can enable spectral imaging with simultaneous scatter correction for CBCT and effectively improve its quantitative imaging performance.
△ Less
Submitted 7 January, 2024; v1 submitted 10 December, 2022;
originally announced December 2022.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Characterization of two SiPM arrays from Hamamatsu and Onsemi for liquid argon detector
Authors:
T. A. Wang,
C. Guo,
X. H. Liang,
L. Wang,
M. Y. Guan,
C. G. Yang,
J. C. Liu,
F. Y. Lin
Abstract:
Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid argon. However, the design of compact SiPM arrays and their cryogenic electronics that can work in liquid argon is barely developed. Thus, two candidate SiPM array…
▽ More
Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid argon. However, the design of compact SiPM arrays and their cryogenic electronics that can work in liquid argon is barely developed. Thus, two candidate SiPM arrays from Hamamatsu and Onsemi were selected to verify the feasibility and effectiveness of the design. In this work, we successfully developed a cryogenic electronics read-out system that connects and works with 1-inch 4$\times$4 SiPM arrays at 87~K. The power dissipation of amplifiers is less than 10 $μ$W/mm$^2$. Furthermore, multiply significant characteristics of both types of SiPM arrays were measured at liquid argon temperature, such as dark count rate (DCR), breakdown voltage (V${_{bd}}$), single photoelectron (SPE) performance, signal to noise ratio (SNR) and correlated signal probability.
△ Less
Submitted 28 October, 2022;
originally announced October 2022.
-
Expected geoneutrino signal at JUNO using local integrated 3-D refined crustal model
Authors:
Ran Han,
ZhiWei Li,
Ruohan Gao,
Yao Sun,
Ya Xu,
Yufei Xi,
Guangzheng Jiang,
Andong Wang,
Yaping Cheng,
Yao Sun,
Jie Pang,
Qi Hua,
Liangjian Wen,
Liang Zhan,
Yu-Feng Li
Abstract:
Geoneutrinos serve as a potent tool for comprehending the radiogenic power and composition of Earth. Although geoneutrinos have been observed in prior experiments, the forthcoming generation of experiments,such as JUNO, will be necessary for fully harnessing their potential. Precise prediction of the crustal contribution is vital for interpreting particlephysics measurements in the context of geo-…
▽ More
Geoneutrinos serve as a potent tool for comprehending the radiogenic power and composition of Earth. Although geoneutrinos have been observed in prior experiments, the forthcoming generation of experiments,such as JUNO, will be necessary for fully harnessing their potential. Precise prediction of the crustal contribution is vital for interpreting particlephysics measurements in the context of geo-scientific inquiries. Nonetheless, existing models such as JULOC and GIGJ have limitations in accurately forecasting the crustal contribution. This paper introduces JULOCI, the novel 3-D integrated crustal model of JUNO, which employs seismic, gravity, rock sample, and heat flow data to precisely estimate the geoneutrino signal of the lithosphere. The model indicates elevated concentrations of uranium and thorium in southern China, resulting in unexpectedly strong geoneutrino signals.The accuracy of JULOC-I, coupled with a decade of experimental data, affords JUNO the opportunity to test multiple mantle models. Once operational, JUNO can validate the model predictions and enhance the precision of mantle measurements. All in all, the improved accuracy ofJULOC-I represents a substantial stride towards comprehending the geochemical distribution of the South China crust, offering a valuable tool for investigating the composition and evolution of the Earth through geoneutrinos.
△ Less
Submitted 6 March, 2024; v1 submitted 17 October, 2022;
originally announced October 2022.
-
5-Minute Magnetic Particle Spectroscopy (MPS)-based Bioassay: Towards Ultra-fast, Convenient, and Large-scale Disease Diagnosis
Authors:
Kai Wu,
Vinit Kumar Chugh,
Venkatramana D. Krishna,
Yongqiang Andrew Wang,
Timothy D. Gordon,
Maxim C-J Cheeran,
Jian-Ping Wang
Abstract:
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detectio…
▽ More
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detection limit below 5 nM (0.2 pmole). Our proposed 5-minute bioassay strategy may be applied to reduce assay time for other liquid phase, volumetric biosensors such as nuclear magnetic resonance (NMR), quantum dots (QD), fluorescent biosensors, etc.
△ Less
Submitted 25 September, 2022;
originally announced October 2022.
-
Single-Shot Quantitative X-ray Imaging Using a Primary Modulator and Dual-Layer Detector
Authors:
Linxi Shi,
N. Robert Bennett,
Alexander Vezeridis,
Nishita Kothary,
Adam Wang
Abstract:
Purpose: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free dual-energy (DE) imaging with scatter correction in a sing…
▽ More
Purpose: Conventional x-ray imaging and fluoroscopy have limitations in quantitation due to several challenges, including scatter, beam hardening, and overlapping tissues. In this work, we propose single-shot quantitative imaging (SSQI) by combining the use of a primary modulator (PM) and dual-layer (DL) detector, which enables motion-free dual-energy (DE) imaging with scatter correction in a single shot.
Methods: The SSQI algorithm allows simultaneous recovery of two material-specific images and two scatter images using four sub-measurements from the PM encoding. For validation, we set up SSQI on our tabletop system and imaged acrylic and copper slabs with known thicknesses, estimated scatter with our SSQI algorithm, and compared the material decomposition (MD) for different combinations of the two materials with ground truth. Second, we imaged an anthropomorphic chest phantom containing contrast in the coronary arteries and compared the MD with and without SSQI. Lastly, to evaluate SSQI in dynamic applications, we constructed a flow phantom that enabled dynamic imaging of iodine contrast.
Results: The root mean squared error (RMSE) of SSQI estimation was 0.13 cm for acrylic and 0.04 mm for copper. For the anthropomorphic phantom, direct MD resulted in incorrect interpretation of contrast and soft tissue, while SSQI successfully distinguished them and reduced RMSE in material-specific images by 38% to 92%. For the flow phantom, SSQI was able to perform accurate dynamic quantitative imaging, separating contrast from the background.
Conclusions: We demonstrated the potential of SSQI for robust quantitative x-ray imaging. The simplicity of SSQI may enable its widespread adoption, including radiography and dynamic imaging such as real-time image guidance and cone-beam CT.
△ Less
Submitted 27 September, 2022;
originally announced September 2022.