-
Accelerated Lifetime Testing and Analysis of Delta-doped Silicon Test Structures
Authors:
Connor Halsey,
Jessica Depoy,
DeAnna M. Campbell,
Daniel R. Ward,
Evan M. Anderson,
Scott W. Schmucker,
Jeffrey A. Ivie,
Xujiao Gao,
David A. Scrymgeour,
Shashank Misra
Abstract:
As transistor features shrink beyond the 2 nm node, studying and designing for atomic scale effects become essential. Being able to combine conventional CMOS with new atomic scale fabrication routes capable of creating 2D patterns of highly doped phosphorus layers with atomic precision has implications for the future of digital electronics. This work establishes the accelerated lifetime tests of s…
▽ More
As transistor features shrink beyond the 2 nm node, studying and designing for atomic scale effects become essential. Being able to combine conventional CMOS with new atomic scale fabrication routes capable of creating 2D patterns of highly doped phosphorus layers with atomic precision has implications for the future of digital electronics. This work establishes the accelerated lifetime tests of such doped layers, showing that these materials survive high current (>3.0 MA/cm2) and 300$^{\circ}$C for greater than 70 days and are still electrically conductive. The doped layers compare well to failures in traditional metal layers like aluminum and copper where mean time to failure at these temperatures and current densities would occur within hours. It also establishes that these materials are more stable than metal features, paving the way toward their integration with operational CMOS.
△ Less
Submitted 24 February, 2022; v1 submitted 22 October, 2021;
originally announced October 2021.
-
Atomic Precision Advanced Manufacturing for Digital Electronics
Authors:
Daniel R. Ward,
Scott W. Schmucker,
Evan M. Anderson,
Ezra Bussmann,
Lisa Tracy,
Tzu-Ming Lu,
Leon N. Maurer,
Andrew Baczewski,
Deanna M. Campbell,
Michael T. Marshall,
Shashank Misra
Abstract:
An exponential increase in the performance of silicon microelectronics and the demand to manufacture in great volumes has created an ecosystem that requires increasingly complex tools to fabricate and characterize the next generation of chips. However, the cost to develop and produce the next generation of these tools has also risen exponentially, to the point where the risk associated with progre…
▽ More
An exponential increase in the performance of silicon microelectronics and the demand to manufacture in great volumes has created an ecosystem that requires increasingly complex tools to fabricate and characterize the next generation of chips. However, the cost to develop and produce the next generation of these tools has also risen exponentially, to the point where the risk associated with progressing to smaller feature sizes has created pain points throughout the ecosystem. The present challenge includes shrinking the smallest features from nanometers to atoms (10 nm corresponds to 30 silicon atoms). Relaxing the requirement for achieving scalable manufacturing creates the opportunity to evaluate ideas not one or two generations into the future, but at the absolute physical limit of atoms themselves. This article describes recent advances in atomic precision advanced manufacturing (APAM) that open the possibility of exploring opportunities in digital electronics. Doing so will require advancing the complexity of APAM devices and integrating APAM with CMOS.
△ Less
Submitted 25 February, 2020;
originally announced February 2020.
-
Low Thermal Budget High-k/Metal Surface Gate for Buried Donor-Based Devices
Authors:
Evan M. Anderson,
DeAnna M. Campbell,
Leon N. Maurer,
Andrew D. Baczewski,
Michael T. Marshall,
Tzu-Ming Lu,
Ping Lu,
Lisa A. Tracy,
Scott W. Schmucker,
Daniel R. Ward,
Shashank Misra
Abstract:
Atomic precision advanced manufacturing (APAM) offers creation of donor devices in an atomically thin layer doped beyond the solid solubility limit, enabling unique device physics. This presents an opportunity to use APAM as a pathfinding platform to investigate digital electronics at the atomic limit. Scaling to smaller transistors is increasingly difficult and expensive, necessitating the invest…
▽ More
Atomic precision advanced manufacturing (APAM) offers creation of donor devices in an atomically thin layer doped beyond the solid solubility limit, enabling unique device physics. This presents an opportunity to use APAM as a pathfinding platform to investigate digital electronics at the atomic limit. Scaling to smaller transistors is increasingly difficult and expensive, necessitating the investigation of alternative fabrication paths that extend to the atomic scale. APAM donor devices can be created using a scanning tunneling microscope (STM). However, these devices are not currently compatible with industry standard fabrication processes. There exists a tradeoff between low thermal budget (LT) processes to limit dopant diffusion and high thermal budget (HT) processes to grow defect-free layers of epitaxial Si and gate oxide. To this end, we have developed an LT epitaxial Si cap and LT deposited Al2O3 gate oxide integrated with an atomically precise single-electron transistor (SET) that we use as an electrometer to characterize the quality of the gate stack. The surface-gated SET exhibits the expected Coulomb blockade behavior. However, the leverage of the gate over the SET is limited by defects in the layers above the SET, including interfaces between the Si and oxide, and structural and chemical defects in the Si cap. We propose a more sophisticated gate stack and process flow that is predicted to improve performance in future atomic precision devices.
△ Less
Submitted 11 June, 2020; v1 submitted 20 February, 2020;
originally announced February 2020.
-
All-optical lithography process for contacting atomically-precise devices
Authors:
Daniel R. Ward,
Michael T. Marshall,
DeAnna M. Campbell,
Tzu-Ming Lu,
Justin C. Koepke,
David A. Scrymgeour,
Ezra Bussmann,
Shashank Misra
Abstract:
We describe an all-optical lithography process that can be used to make electrical contact to atomic-precision donor devices made in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a pat…
▽ More
We describe an all-optical lithography process that can be used to make electrical contact to atomic-precision donor devices made in silicon using scanning tunneling microscopy (STM). This is accomplished by implementing a cleaning procedure in the STM that allows the integration of metal alignment marks and ion-implanted contacts at the wafer level. Low-temperature transport measurements of a patterned device establish the viability of the process.
△ Less
Submitted 8 August, 2017;
originally announced August 2017.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada
, et al. (194 additional authors not shown)
Abstract:
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig…
▽ More
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid.
A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.
△ Less
Submitted 13 January, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (148 additional authors not shown)
Abstract:
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are…
▽ More
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.
△ Less
Submitted 15 June, 2014; v1 submitted 13 June, 2013;
originally announced June 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;
originally announced May 2013.
-
Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques
Authors:
CALICE Collaboration,
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (142 additional authors not shown)
Abstract:
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advan…
▽ More
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.
△ Less
Submitted 27 September, 2012; v1 submitted 17 July, 2012;
originally announced July 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.
-
Development of a modular and scalable data acquisition system for calorimeters at a linear collider
Authors:
M. J. Goodrick,
L. B. A. Hommels,
R. Shaw,
D. R. Ward,
D. S. Bailey,
M. Kelly,
V. Boisvert,
B. Green,
M. G. Green,
A. Misiejuk,
T. Wu,
V. Bartsch,
M. Postranecky,
M. Warren,
M. Wing
Abstract:
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial devel…
▽ More
A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial development board housed in a PC and a chain of concentrator cards between it and the detector forming the basis of the system. As well as describing the concept and performance of the system, its merits and disadvantages are discussed.
△ Less
Submitted 4 October, 2011; v1 submitted 29 June, 2011;
originally announced June 2011.
-
Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Ribon,
V. Uzhinskiy,
M. Benyamna,
C. Cârloganu,
F. Fehr,
P. Gay,
G. C. Blazey,
D. Chakraborty
, et al. (133 additional authors not shown)
Abstract:
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the…
▽ More
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.
△ Less
Submitted 28 April, 2010;
originally announced April 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.
-
Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
Authors:
CALICE Collaboration,
J. Repond,
J. Yu,
C. M. Hawkes,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
F. Badaud,
D. Boumediene,
C. Carloganu,
R. Cornat,
P. Gay,
Ph. Gris,
S. Manen,
F. Morisseau,
L. Royer,
G. C. Blazey,
D. Chakraborty,
A. Dyshkant,
K. Francis
, et al. (92 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.
△ Less
Submitted 5 August, 2008; v1 submitted 29 May, 2008;
originally announced May 2008.