-
Symmetry engineering in 2D bioelectronics facilitating augmented biosensing interfaces
Authors:
Yizhang Wu,
Yihan Liu,
Yuan Li,
Ziquan Wei,
Sicheng Xing,
Yunlang Wang,
Dashuai Zhu,
Ziheng Guo,
Anran Zhang,
Gongkai Yuan,
Zhibo Zhang,
Ke Huang,
Yong Wang,
Guorong Wu,
Ke Cheng,
Wubin Bai
Abstract:
Symmetry lies at the heart of 2D bioelectronics, determining material properties at the fundamental level. Breaking the symmetry allows emergent functionalities and effects. However, symmetry modulation in 2D bioelectronics and the resultant applications have been largely overlooked. Here we devise an oxidized architectural MXene, referred as OXene, that couples orbit symmetric breaking with inver…
▽ More
Symmetry lies at the heart of 2D bioelectronics, determining material properties at the fundamental level. Breaking the symmetry allows emergent functionalities and effects. However, symmetry modulation in 2D bioelectronics and the resultant applications have been largely overlooked. Here we devise an oxidized architectural MXene, referred as OXene, that couples orbit symmetric breaking with inverse symmetric breaking to entitle the optimized interfacial impedance and Schottky-induced piezoelectric effects. The resulting OXene validates applications ranging from microelectrode arrays, gait analysis, active transistor matrix, and wireless signaling transmission, which enables highly-fidelity signal transmission and reconfigurable logic gates. Further OXene interfaces are investigated in both rodent and porcine myocardium, featuring high-quality and spatiotemporally resolved physiological recordings, while accurate differentiated predictions, enabled via various machine learning pipelines.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Orbit symmetry breaking in MXene implements enhanced soft bioelectronic implants
Authors:
Yizhang Wu,
Yuan Li,
Yihan Liu,
Dashuai Zhu,
Sicheng Xing,
Noah Lambert,
Hannah Weisbecker,
Siyuan Liu,
Brayden Davis,
Lin Zhang,
Meixiang Wang,
Gongkai Yuan,
Chris Zhoufan You,
Anran Zhang,
Cate Duncan,
Wanrong Xie,
Yihang Wang,
Yong Wang,
Sreya Kanamurlapudi,
Garcia-Guzman Evert,
Arjun Putcha,
Michael D. Dickey,
Ke Huang,
Wubin Bai
Abstract:
Bioelectronic implants with soft mechanics, biocompatibility, and excellent electrical performance enable biomedical implants to record electrophysiological signals and execute interventions within internal organs, promising to revolutionize the diagnosing, monitoring, and treatment of various pathological conditions. However, challenges remain in improving excessive impedance at the bioelectronic…
▽ More
Bioelectronic implants with soft mechanics, biocompatibility, and excellent electrical performance enable biomedical implants to record electrophysiological signals and execute interventions within internal organs, promising to revolutionize the diagnosing, monitoring, and treatment of various pathological conditions. However, challenges remain in improving excessive impedance at the bioelectronic-tissue interface and thus the efficacy of electrophysiological signaling and intervention. Here, we devise orbit symmetry breaking in MXene (a low-cost scalability, biocompatible, and conductive 2D layered material, that we refer to as OBXene), that exhibits low bioelectronic-tissue impedance, originating from the out-of-plane charge transfer. Furthermore, the Schottky-induced piezoelectricity stemming from the asymmetric orbital configuration of OBXene facilitates interlayered charge transport in the device. In this study, we report an OBXene-based cardiac patch applied on the left ventricular epicardium of both rodent and porcine models to enable spatiotemporal epicardium mapping and pacing, while coupling the wireless and battery-free operation for long-term real-time recording and closed-loop stimulation.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Multi-watt 1 GHz single-cycle frequency combs
Authors:
Yanyan Zhang,
Sida Xing
Abstract:
Single-cycle optical pulses offer a strong carrier-envelope-offset (CEO) dependent electric field and the highest peak intensity for a given pulse energy. Absence of demonstrated GHz single-cycle lasers constrains exploration of single/sub-cycle dynamics at this repetition rate. By leveraging fiber soliton effects and suppressing higher-order dispersion, we achieve single-cycle pulse generation at…
▽ More
Single-cycle optical pulses offer a strong carrier-envelope-offset (CEO) dependent electric field and the highest peak intensity for a given pulse energy. Absence of demonstrated GHz single-cycle lasers constrains exploration of single/sub-cycle dynamics at this repetition rate. By leveraging fiber soliton effects and suppressing higher-order dispersion, we achieve single-cycle pulse generation at a 1 GHz repetition rate in an all-fiber format. The laser produces 7.1 fs (1.1-cycle) pulses with 1.8 W average power, centered around 1970 nm. Temporal characterization shows 60% of the pulse energy is concentrated in the pulse center, yielding a peak power of 110 kW. The seed laser demonstrates a 43 dB signal-to-noise ratio for the CEO frequency, facilitating comb stabilization and CEO control. Our model, which matches experimental observations, identifies conditions for achieving single-cycle duration and predicts scalability to a 2 GHz repetition rate. This work presents the first GHz single-cycle source. We envision these advances will drive studies in single/sub-cycle light-matter interaction, spectroscopy, microscopy, and CEO-sensitive nonlinear optics.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Two-octave frequency combs from all-silica-fiber implementation
Authors:
Yanyan Zhang,
Mingkun Li,
Pan Zhang,
Yueqing Du,
Shibang Ma,
Yuanshan Liu,
Sida Xing,
Shougang Zhang
Abstract:
Mid-infrared frequency comb spectroscopy enables measurement of molecular at megahertz spectral resolution, sub-hertz frequency accuracy and microsecond acquisition speed. However, the widespread adoption of this technique has been hindered by the complexity and alignment sensitivity of mid-infrared frequency comb sources. Leveraging the underexplored mid-infrared window of silica fibers presents…
▽ More
Mid-infrared frequency comb spectroscopy enables measurement of molecular at megahertz spectral resolution, sub-hertz frequency accuracy and microsecond acquisition speed. However, the widespread adoption of this technique has been hindered by the complexity and alignment sensitivity of mid-infrared frequency comb sources. Leveraging the underexplored mid-infrared window of silica fibers presents a promising approach to address these challenges. In this study, we present the first experimental demonstration and quantitative numerical description of mid-infrared frequency comb generation in silica fibers. Our all-silica-fiber frequency comb spans over two octaves (0.8 $μ$m to 3.5 $μ$m) with a power output of 100 mW in the mid-infrared region. The amplified quantum noise is suppressed using four-cycle (25 fs) driving pulses, with the carrier-envelope offset frequency exhibiting a signal-to-noise ratio of 40 dB and a free-running bandwidth of 90 kHz. Our developed model provides quantitative guidelines for mid-infrared frequency comb generation in silica fibers, enabling all-fiber frequency comb spectroscopy in diverse fields such as organic synthesis, pharmacokinetics processes, and environmental monitoring.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Study of Efficient Photonic Chromatic Dispersion Equalization Using MZI-Based Coherent Optical Matrix Multiplication
Authors:
Sizhe Xing,
Guoqiang Li,
Ziwei Li,
Nan Chi,
Junwen Zhang
Abstract:
We propose and study an efficient photonic CDE method using MZI-based coherent optical matrix multiplication. It improves the compensation performance by about 60% when the tap-length is limited, and only 50% taps of the theoretical value is needed for photonic CDE with 1-dB penalty.
We propose and study an efficient photonic CDE method using MZI-based coherent optical matrix multiplication. It improves the compensation performance by about 60% when the tap-length is limited, and only 50% taps of the theoretical value is needed for photonic CDE with 1-dB penalty.
△ Less
Submitted 20 May, 2022;
originally announced June 2022.
-
Pitfalls in gpr data interpretation: false reflectors detected in lunar radar cross sections by Chang'e-3
Authors:
Chunlai Li,
Shuguo Xing,
Sebastian E. Lauro,
Yan Su,
Shun Dai,
Jianqing Feng,
Barbara Cosciotti,
Federico Di Paolo,
Elisabetta Mattei,
Yuan Xiao,
Chunyu Ding,
Elena Pettinelli
Abstract:
Chang'e-3(CE-3) has been the first spacecraft to soft-land on the Moon since the Soviet Union's Luna 24 in 1976. The spacecraft arrived at Mare Imbrium on December 14, 2013 and the same day, Yutu lunar rover separated from lander to start its exploration of the surface and the subsurface around the landing site. The rover was equipped, among other instruments, with two Lunar Penetrating Radar syst…
▽ More
Chang'e-3(CE-3) has been the first spacecraft to soft-land on the Moon since the Soviet Union's Luna 24 in 1976. The spacecraft arrived at Mare Imbrium on December 14, 2013 and the same day, Yutu lunar rover separated from lander to start its exploration of the surface and the subsurface around the landing site. The rover was equipped, among other instruments, with two Lunar Penetrating Radar systems (LPR) having a working frequency of 60 and 500 MHz. The radars acquired data for about two weeks while the rover was slowly moving along a path of about 114 m. At Navigation point N0209 the rover got stacked into the lunar soil and after that only data at fixed position could be collected. The low frequency radar data have been analyzed by different authors and published in two different papers, which reported totally controversial interpretations of the radar cross sections. The present study is devoted to resolve such controversy carefully analyzing and comparing the data collected on the Moon by Yutu rover and on Earth by a prototype of LRP mounted onboard a model of the CE-3 lunar rover. Such analysis demonstrates that the deep radar features previously ascribed to the lunar shallow stratigraphy are not real reflectors, rather they are signal artefacts probably generated by the system and its electromagnetic interaction with the metallic rover.
△ Less
Submitted 31 May, 2022;
originally announced May 2022.
-
Efficient and ultra-stable perovskite light-emitting diodes
Authors:
Bingbing Guo,
Runchen Lai,
Sijie Jiang,
Yaxiao Lian,
Zhixiang Ren,
Puyang Li,
Xuhui Cao,
Shiyu Xing,
Yaxin Wang,
Weiwei Li,
Chen Zou,
Mengyu Chen,
Cheng Li,
Baodan Zhao,
Dawei Di
Abstract:
Perovskite light-emitting diodes (PeLEDs) have emerged as a strong contender for next-generation display and information technologies. However, similar to perovskite solar cells, the poor operational stability remains the main obstacle toward commercial applications. Here we demonstrate ultra-stable and efficient PeLEDs with extraordinary operational lifetimes (T50) of 1.0x10^4 h, 2.8x10^4 h, 5.4x…
▽ More
Perovskite light-emitting diodes (PeLEDs) have emerged as a strong contender for next-generation display and information technologies. However, similar to perovskite solar cells, the poor operational stability remains the main obstacle toward commercial applications. Here we demonstrate ultra-stable and efficient PeLEDs with extraordinary operational lifetimes (T50) of 1.0x10^4 h, 2.8x10^4 h, 5.4x10^5 h, and 1.9x10^6 h at initial radiance (or current densities) of 3.7 W/sr/m2 (~5 mA/cm2), 2.1 W/sr/m2 (~3.2 mA/cm2), 0.42 W/sr/m2 (~1.1 mA/cm2), and 0.21 W/sr/m2 (~0.7 mA/cm2) respectively, and external quantum efficiencies of up to 22.8%. Key to this breakthrough is the introduction of a dipolar molecular stabilizer, which serves two critical roles simultaneously. First, it prevents the detrimental transformation and decomposition of the alpha-phase FAPbI3 perovskite, by inhibiting the formation of lead and iodide intermediates. Secondly, hysteresis-free device operation and microscopic luminescence imaging experiments reveal substantially suppressed ion migration in the emissive perovskite. The record-long PeLED lifespans are encouraging, as they now satisfy the stability requirement for commercial organic LEDs (OLEDs). These results remove the critical concern that halide perovskite devices may be intrinsically unstable, paving the path toward industrial applications.
△ Less
Submitted 16 April, 2022;
originally announced April 2022.
-
1-GHz mid-infrared frequency comb spanning 3 to 13 μm
Authors:
Nazanin Hoghooghi,
Sida Xing,
Peter Chang,
Daniel Lesko,
Alexander Lind,
Greg Rieker,
Scott Diddams
Abstract:
Mid-infrared (MIR) spectrometers are invaluable tools for molecular fingerprinting and hyper-spectral imaging. Among the available spectroscopic approaches, GHz MIR dual-comb absorption spectrometers have the potential to simultaneously combine the high-speed, high spectral resolution, and broad optical bandwidth needed to accurately study complex, transient events in chemistry, combustion, and mi…
▽ More
Mid-infrared (MIR) spectrometers are invaluable tools for molecular fingerprinting and hyper-spectral imaging. Among the available spectroscopic approaches, GHz MIR dual-comb absorption spectrometers have the potential to simultaneously combine the high-speed, high spectral resolution, and broad optical bandwidth needed to accurately study complex, transient events in chemistry, combustion, and microscopy. However, such a spectrometer has not yet been demonstrated due to the lack of GHz MIR frequency combs with broad and full spectral coverage. Here, we introduce the first broadband MIR frequency comb laser platform at 1 GHz repetition rate that achieves spectral coverage from 3 to 13 μm. This frequency comb is based on a commercially available 1.56 μm mode-locked laser, robust all-fiber Er amplifiers and intra-pulse difference frequency generation (IP-DFG) of few-cycle pulses in \c{hi}(2) nonlinear crystals. When used in a dual comb spectroscopy (DCS) configuration, this source will simultaneously enable measurements with μs time resolution, 1 GHz (0.03 cm-1) spectral point spacing and a full bandwidth of >5 THz (>166 cm-1) anywhere within the MIR atmospheric windows. This represents a unique spectroscopic resource for characterizing fast and non-repetitive events that are currently inaccessible with other sources.
△ Less
Submitted 18 January, 2022;
originally announced January 2022.
-
Beyond 300Gbps Silicon Microring Modulator with AI Acceleration
Authors:
Fangchen Hu,
Yuguang Zhang,
Hongguang Zhang,
Zhongya Li,
Sizhe Xing,
Jianyang Shi,
Junwen Zhang,
Xi Xiao,
Nan Chi,
Zhixue He,
Shaohua Yu
Abstract:
Silicon microring modulator (Si-MRM) has become one of the most promising compact modulators to meet the increasing capacity requirements of the next generation optical interconnection. The limited electro-optical (E-O) bandwidth, low modulation efficiency, and inherent modulation nonlinearity are the major factors that limit the Si-MRM modulation speed. To address these issues, we comprehensively…
▽ More
Silicon microring modulator (Si-MRM) has become one of the most promising compact modulators to meet the increasing capacity requirements of the next generation optical interconnection. The limited electro-optical (E-O) bandwidth, low modulation efficiency, and inherent modulation nonlinearity are the major factors that limit the Si-MRM modulation speed. To address these issues, we comprehensively optimize the Si-MRM from the device to the modulation and the signal processing. Large modulation bandwidth over 67GHz is achieved in our newly fabricated Si-MRM. Additionally, the laser wavelength and bias voltage of Si-MRM are optimized to significantly improve the modulation performance. Finally, we comprehensively study the theoretical model of modulation nonlinearity in Si-MRM, especially transient nonlinearity. A bidirectional gate recurrent unit (Bi-GRU) neural network with minor modification is applied to compensate for the nonlinear impairments. With all these efforts, we experimentally demonstrate a 302 Gbps Si-MRM-based O-band optical interconnection and achieve 300 Gbps transmission over a 1-km standard single-mode fiber using the discrete multitone modulation format with bit and power loading (BPL-DMT).
△ Less
Submitted 8 November, 2021;
originally announced November 2021.
-
Ultralow-voltage operation of light-emitting diodes
Authors:
Yaxiao Lian,
Dongchen Lan,
Shiyu Xing,
Bingbing Guo,
Runchen Lai,
Baodan Zhao,
Richard H. Friend,
Dawei Di
Abstract:
The radiative recombination of injected charge carriers gives rise to electroluminescence (EL), a central process for light-emitting diode (LED) operation. It is often presumed in some emerging fields of optoelectronics, including perovskite and organic LEDs, that the minimum voltage required for light emission is the semiconductor bandgap divided by the elementary charge. Here we show for many cl…
▽ More
The radiative recombination of injected charge carriers gives rise to electroluminescence (EL), a central process for light-emitting diode (LED) operation. It is often presumed in some emerging fields of optoelectronics, including perovskite and organic LEDs, that the minimum voltage required for light emission is the semiconductor bandgap divided by the elementary charge. Here we show for many classes of LEDs, including those based on metal halide perovskite, organic, chalcogenide quantum-dot and commercial III-V semiconductors, photon emission can be generally observed at record-low driving voltages of 36%-60% of their bandgaps, corresponding to a large apparent energy gain of 0.6-1.4 eV per emitted photon. Importantly, for various classes of LEDs with very different modes of charge injection and recombination (dark saturation current densities ranging from ~10^-35 to ~10^-21 mA/cm2), their EL intensity-voltage curves under low voltages exhibit similar behaviors, revealing a universal origin of ultralow-voltage device operation. Finally, we demonstrate as a proof-of-concept that perovskite LEDs can transmit data efficiently to a silicon detector at 1V, a voltage below the silicon bandgap. Our work provides a fresh insight into the operational limits of electroluminescent diodes, highlighting the significant potential of integrating low-voltage LEDs with silicon electronics for next-generation communications and computational applications.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Single-cycle all-fiber frequency comb
Authors:
Sida Xing,
Daniel Lesko,
Takeshi Umeki,
Alexander Lind,
Nazanin Hoghooghi,
Tsung-han wu,
Scott Diddams
Abstract:
Single-cycle pulses with deterministic carrier-envelope phase enable the study and control of light-matter interactions at the sub-cycle timescale, as well as the efficient generation of low-noise multi-octave frequency combs. However, current single-cycle light sources are difficult to implement and operate, hindering their application and accessibility in a wider range of research. In this paper…
▽ More
Single-cycle pulses with deterministic carrier-envelope phase enable the study and control of light-matter interactions at the sub-cycle timescale, as well as the efficient generation of low-noise multi-octave frequency combs. However, current single-cycle light sources are difficult to implement and operate, hindering their application and accessibility in a wider range of research. In this paper, we present a single-cycle 100 MHz frequency comb in a compact, turn-key, and reliable all-silica-fiber format. This is achieved by amplifying 2 $μ$m seed pulses in heavily-doped Tm:fiber, followed by cascaded self-compression to yield 6.8 fs pulses with 215 kW peak power and 374 mW average power. The corresponding spectrum covers more than two octaves, from below 700 nm up to 3500 nm. Driven by this single-cycle pump, supercontinuum with 180 mW of integrated power and a smooth spectral amplitude between 2100 and 2700 nm is generated directly in silica fibers. To broaden applications,few-cycle pulses extending from 6 $μ$m to beyond 22 $μ$m with long-term stable carrier-envelope phase are created using intra-pulse difference frequency, and electro-optic sampling yields comb-tooth-resolved spectra. Our work demonstrates the first all-fiber configuration that generates single-cycle pulses, and provides a practical source to study nonlinear optics on the same timescale.
△ Less
Submitted 6 July, 2021; v1 submitted 29 April, 2021;
originally announced April 2021.
-
A six-octave optical frequency comb from a scalable few-cycle erbium fiber laser
Authors:
Daniel M. B. Lesko,
Henry Timmers,
Sida Xing,
Abijith Kowligy,
Alexander J. Lind,
Scott A. Diddams
Abstract:
A compact and robust coherent laser light source that provides spectral coverage from the ultraviolet to infrared is desirable for numerous applications, including heterodyne super resolution imaging[1], broadband infrared microscopy[2], protein structure determination[3], and standoff atmospheric trace-gas detection[4]. Addressing these demanding measurement problems, laser frequency combs[5] com…
▽ More
A compact and robust coherent laser light source that provides spectral coverage from the ultraviolet to infrared is desirable for numerous applications, including heterodyne super resolution imaging[1], broadband infrared microscopy[2], protein structure determination[3], and standoff atmospheric trace-gas detection[4]. Addressing these demanding measurement problems, laser frequency combs[5] combine user-defined spectral resolution with sub-femtosecond timing and waveform control to enable new modalities of high-resolution, high-speed, and broadband spectroscopy[6-9]. In this Letter we introduce a scalable source of near-single-cycle, 0.56 MW pulses generated from robust and low-noise erbium fiber (Er:fiber) technology, and we use it to generate a frequency comb that spans six octaves from the ultraviolet (350 nm) to mid-infrared (22500 nm). The high peak power allows us to exploit the second-order nonlinearities in infrared-transparent, nonlinear crystals (LiNbO$_3$, GaSe, and CSP) to provide a robust source of phase-stable infrared ultra-short pulses with simultaneous spectral brightness exceeding that of an infrared synchrotron[10]. Additional cascaded second-order nonlinearities in LiNbO$_3$ lead to comb generation with four octaves of simultaneous coverage (0.350 to 5.6 $μ$m). With a comb-tooth linewidth of 10 kHz at 193 THz, we realize a notable spectral resolving power exceeding 10$^{10}$ across 0.86 PHz of bandwidth. We anticipate that this compact and accessible technology will open new opportunities for multi-band precision spectroscopy, coherent microscopy, ultra-high sensitivity nanoscopy, astronomical spectroscopy, and precision carrier-envelope phase (CEP) stable strong field phenomena.
△ Less
Submitted 27 May, 2020;
originally announced May 2020.
-
All-fiber frequency comb at 2 μm providing 1.4-cycle pulses
Authors:
Sida Xing,
Abijith S. Kowligy,
Daniel M. B. Lesko,
Alexander J. Lind,
Scott A. Diddams
Abstract:
We report an all-polarization-maintaining fiber optic approach to generating sub-2 cycle pulses at 2 μm and a corresponding octave-spanning optical frequency comb. Our configuration leverages mature Er:fiber laser technology at 1.5 μm to provide a seed pulse for a thulium-doped fiber amplifier that outputs 330 mW average power at 100 MHz repetition rate. Following amplification, nonlinear self-com…
▽ More
We report an all-polarization-maintaining fiber optic approach to generating sub-2 cycle pulses at 2 μm and a corresponding octave-spanning optical frequency comb. Our configuration leverages mature Er:fiber laser technology at 1.5 μm to provide a seed pulse for a thulium-doped fiber amplifier that outputs 330 mW average power at 100 MHz repetition rate. Following amplification, nonlinear self-compression in fiber decreases the pulse duration to 9.5 fs, or 1.4 optical cycles. Approximately 32 % of the energy sits within the pulse peak, and the polarization extinction ratio is more than 15 dB. The spectrum of the ultrashort pulse spans from 1 μm to beyond 2.4 μm and enables direct measurement of the carrier-envelope offset frequency using only 12 mW, or ~3.5 % of the total power. Our approach employs only commercially-available fiber components, resulting in a turnkey amplifier design that is compact, and easy to reproduce in the larger community. Moreover, the overall design and self-compression mechanism are scalable in repetition rate and power. As such, this system should be useful as a robust frequency comb source in the near-infrared or as a pump source to generate mid-infrared frequency combs.
△ Less
Submitted 6 March, 2020; v1 submitted 26 February, 2020;
originally announced February 2020.
-
Mid-infrared continuous wave parametric amplification in tapered chalcogenide microstructured fibers
Authors:
Sida Xing,
Davide Grassani,
Svyatoslav Kharitonov,
Laurent Brilland,
Céline Caillaud,
Johann Trolès,
Camille-Sophie Brès
Abstract:
As photon mixing is not inherently limited to any specific spectral region, parametric processes represent a compelling solution for all-optical signal processing in spectral windows not easily accessible by other technologies. Particularly, the continuous-wave pumping scheme is essential for any application requiring modulated signals or precise spectroscopic characterization. Highly nonlinear fi…
▽ More
As photon mixing is not inherently limited to any specific spectral region, parametric processes represent a compelling solution for all-optical signal processing in spectral windows not easily accessible by other technologies. Particularly, the continuous-wave pumping scheme is essential for any application requiring modulated signals or precise spectroscopic characterization. Highly nonlinear fibers enabled record performances for wavelength conversion and amplification in the telecommunication band, however no waveguiding platforms have yet solved the trade-off between high-nonlinearity, low propagation losses and dispersion in the mid-infrared. Here, we show mid-infrared continuous-wave parametric amplification in a GeAsSe fiber. Leveraging state-of-the-art fabrication techniques, a novel tapered photonic crystal fiber geometry enabling 4.5 dB signal amplification and 2 dB idler conversion efficiency is experimentally demonstrated using only 125 mW of pump in the 2 micron wavelength range. This result is not only the first ever continuous-wave parametric amplification measured at 2 micron, in any waveguide, but also establishes GeAsSe PCF tapers as the most promising all-fibered, high efficiency continuous-wave parametric converter for advanced applications in the mid-infrared.
△ Less
Submitted 2 December, 2016;
originally announced December 2016.