Efficient optical beam displacement measurements using high-order Hermite-Gaussian modes
Authors:
A. L. S. Santos Junior,
M. Gil de Oliveira,
E. V. S. Cubas,
A. Z. Khoury,
G. B. Alves
Abstract:
We develop a novel interferometric technique to measure small angular and lateral displacements of an optical beam. The technique relies on the metrological performance of the Hermite-Gaussian $HG_{m,0}$ spatial modes. We report an improvement factor of $41$ in the signal-to-noise ratio, as compared to the Gaussian mode, using modes as high as $m=20$. This considerably enhances the sensitivity of…
▽ More
We develop a novel interferometric technique to measure small angular and lateral displacements of an optical beam. The technique relies on the metrological performance of the Hermite-Gaussian $HG_{m,0}$ spatial modes. We report an improvement factor of $41$ in the signal-to-noise ratio, as compared to the Gaussian mode, using modes as high as $m=20$. This considerably enhances the sensitivity of such measurements and attests its efficiency.
△ Less
Submitted 14 May, 2024;
originally announced May 2024.
-
Quantum-controlled cluster states
Authors:
R. F. Barros,
G. B. Alves,
O. Pfister,
A. Z. Khoury
Abstract:
Quantum optical cluster states have been increasingly explored, in the light of their importance for measurement-based quantum computing. Here we set forth a new method for generating quantum controlled cluster states: pumping an optical parametric oscillator with spatially structured light. We show that state-of-the-art techniques for producing clusters in the spectral and temporal domains are im…
▽ More
Quantum optical cluster states have been increasingly explored, in the light of their importance for measurement-based quantum computing. Here we set forth a new method for generating quantum controlled cluster states: pumping an optical parametric oscillator with spatially structured light. We show that state-of-the-art techniques for producing clusters in the spectral and temporal domains are improved by a structured light pump, which manipulates the spatial mode couplings in the parametric interaction. We illustrate the method considering a second-order pump structure, and show that a simple mode rotation yields different cluster states, including, but not limited to the two-dimensional square and hexagonal lattices. We also introduce a novel technique for generating non-uniform cluster states, and propose a simple setup for its implementation.
△ Less
Submitted 6 September, 2021; v1 submitted 30 December, 2020;
originally announced December 2020.
-
Gouy-phase effects in the frequency combs of an optical parametric oscillator
Authors:
R. F. Barros,
G. B. Alves,
A. Z. Khoury
Abstract:
We investigate the transverse mode effects on the frequency combs generated by a type-I optical parametric oscillator (OPO) below threshold. We take the diffraction effects fully into account, considering usual OPO architectures instead of the self-imaging design. Further, we show that an OPO pumped with structured light produces multiple frequency combs simultaneously, corresponding to different…
▽ More
We investigate the transverse mode effects on the frequency combs generated by a type-I optical parametric oscillator (OPO) below threshold. We take the diffraction effects fully into account, considering usual OPO architectures instead of the self-imaging design. Further, we show that an OPO pumped with structured light produces multiple frequency combs simultaneously, corresponding to different combinations of spatial modes in the downconverted fields. This result may apply to the production of hybrid multipartite entanglement in the spatiotemporal modes of a single OPO.
△ Less
Submitted 10 February, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
Achieving metrological precision limits through post-selection
Authors:
G. Bié Alves,
A. Pimentel,
M. Hor-Meyll,
S. P. Walborn,
L. Davidovich,
R. L. de Matos Filho
Abstract:
Post-selection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different post-selection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method, tha…
▽ More
Post-selection strategies have been proposed with the aim of amplifying weak signals, which may help to overcome detection thresholds associated with technical noise in high-precision measurements. Here we use an optical setup to experimentally explore two different post-selection protocols for the estimation of a small parameter: a weak-value amplification procedure and an alternative method, that does not provide amplification, but nonetheless is shown to be more robust for the sake of parameter estimation. Each technique leads approximately to the saturation of quantum limits for the estimation precision, expressed by the Cramér-Rao bound. For both situations, we show that information on the parameter is obtained jointly from the measuring device and the post-selection statistics.
△ Less
Submitted 10 June, 2016;
originally announced June 2016.
-
Experimentally quantifying the advantages of weak-value-based metrology
Authors:
Gerardo I. Viza,
Julián Martínez-Rincón,
Gabriel B. Alves,
Andrew N. Jordan,
John C. Howell
Abstract:
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By…
▽ More
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-values technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-values-based technique. By postselecting on $1\%$ of the photons, we obtain $99\%$ of the available Fisher information of the beam deflection parameter.
△ Less
Submitted 23 September, 2015; v1 submitted 30 October, 2014;
originally announced October 2014.
-
Weak-value amplification as an optimal metrological protocol
Authors:
G. Bié Alves,
B. M. Escher,
R. L. de Matos Filho,
N. Zagury,
L. Davidovich
Abstract:
The implementation of weak-value amplification requires the pre- and post-selection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful post-selection events. Here we derive an optimal post-selection procedure for estimating the coupling constant between system…
▽ More
The implementation of weak-value amplification requires the pre- and post-selection of states of a quantum system, followed by the observation of the response of the meter, which interacts weakly with the system. Data acquisition from the meter is conditioned to successful post-selection events. Here we derive an optimal post-selection procedure for estimating the coupling constant between system and meter, and show that it leads both to weak-value amplification and to the saturation of the quantum Fisher information, under conditions fulfilled by all previously reported experiments on the amplification of weak signals. For most of the pre-selected states, full information on the coupling constant can be extracted from the meter data set alone, while for a small fraction of the space of pre-selected states, it must be obtained from the post-selection statistics.
△ Less
Submitted 27 October, 2014;
originally announced October 2014.