Additive Manufactured and Topology Optimized Permanent Magnet Spin-Rotator for Neutron Interferometry Applications
Authors:
Wenzel Kersten,
Laurids Brandl,
Richard Wagner,
Christian Huber,
Florian Bruckner,
Yuji Hasegawa,
Dieter Suess,
Stephan Sponar
Abstract:
In neutron interferometric experiments using polarized neutrons coherent spin-rotation control is required. In this letter we present a new method for Larmor spin-rotation around an axis parallel to the outer guide field using topology optimized 3D printed magnets. The use of 3D printed magnets instead of magnetic coils avoids unwanted inductances and offers the advantage of no heat dissipation, w…
▽ More
In neutron interferometric experiments using polarized neutrons coherent spin-rotation control is required. In this letter we present a new method for Larmor spin-rotation around an axis parallel to the outer guide field using topology optimized 3D printed magnets. The use of 3D printed magnets instead of magnetic coils avoids unwanted inductances and offers the advantage of no heat dissipation, which prevents potential loss in interferometric contrast due to temperature gradients in the interferometer. We use topology optimization to arrive at a design of the magnet geometry that is optimized for homogeneity of the magnetic action over the neutron beam profile and adjustability by varying the distance between the 3D printed magnets. We verify the performance in polarimetric and interferometric neutron experiments.
△ Less
Submitted 31 October, 2018;
originally announced October 2018.
Building blocks for future detectors: Silicon test masses and 1550 nm laser light
Authors:
R. Schnabel,
M. Britzger,
F. Brückner,
O. Burmeister,
K. Danzmann,
J. Dück,
T. Eberle,
D. Friedrich,
H. Lück,
M. Mehmet,
R. Nawrodt,
S. Steinlechner,
B. Willke
Abstract:
Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatu…
▽ More
Current interferometric gravitational wave detectors use the combination of quasi-monochromatic, continuous-wave laser light at 1064 nm and fused silica test masses at room temperature. Detectors of the third generation, such as the Einstein-Telescope, will involve a considerable sensitivity increase. The combination of 1550 nm laser radiation and crystalline silicon test masses at low temperatures might be important ingredients in order to achieve the sensitivity goal. Here we compare some properties of the fused silica and silicon test mass materials relevant for decreasing the thermal noise in future detectors as well as the recent technology achievements in the preparation of laser radiation at 1064 nm and 1550 nm relevant for decreasing the quantum noise. We conclude that silicon test masses and 1550 nm laser light have the potential to form the future building blocks of gravitational wave detection.
△ Less
Submitted 16 December, 2009;
originally announced December 2009.