(Translated by https://www.hiragana.jp/)
GitHub - Ozonised/TPFR_Meter: Arduino UNO based Temperature, PWM generator, Frequency and RPM meter.
Skip to content

Arduino UNO based Temperature, PWM generator, Frequency and RPM meter.

Notifications You must be signed in to change notification settings

Ozonised/TPFR_Meter

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

56 Commits
 
 
 
 
 
 
 
 

Repository files navigation

TPFR_Meter

TPFR_Meter

This is an ATmega328p based Temperature, PWM generator, Frequency counter and RPM meter.

BACK STORY

Often when creating circuits involving MOSFETs or motor drivers, I happen to find a need for a temperature sensor to measure the temperatures of my MOSFETs, a PWM generator to control the speed of motors or to test servos. Not only did have a need for a PWM generator but also a frequency counter when tinkering around with ne555 cicuits based oscillator circuits. Designing separate circuits to fullfill each of my needs would prove to time consuming, expensive and would require additional space to store all the devices. Thus, the idea of creating all purpose meter to measure temperature, generate PWM signals, measure Frequency and RPM struck me which resulted in me creating this multi purpose meter called the TPFR meter.

What does TPFR mean?

Well TPFR stands for Temperature(T), PWM(P), Frequency(F) and RPM(R) which is representative of the functionality of this meter.

FEATURES:

1. TEMPERATURE

TEMPERATURE

The temperature measurement is done with the help of a ds18b20 waterproof temperature sensor with a max measurable temperature of 125 degree celsius and a minimum of -55 degree celsius.

2. PWM

PWM

The PWM signals are generated using the timer1 of the 328p with a frequency range of 31Hzへるつ - 100KHz and a variable duty cycle from 0 - 100%. The frequency range is subdivied into 4 ranges:

Range Frequency Range
1 31Hzへるつ - 1KHz
2 1KHz - 10KHz
3 10KHz - 40KHz
4 40KHz - 100KHz

3. FREQUENCY COUNTER

FREQUENCY_COUNTER

The frequency counter mode as the name implies measures the frequency of the input signal with an accuracy of 99.8%. The error% is usually around 0.02% - 0.01%. The maximum error% that I recorded was 0.2%. I do not know the maximum measurable frequency since my test setup could only reach a maximum frequency of 100Khz.

4. RPM

RPM

This mode uses the timer1's input capture register to measure the period of the input signal and then computes the revolution per minute(RPM) and the revolution per second(RPS). The maximum measurable RPM is in the vicinity of 100,000 RPM(approx). Unfortunately, I do not have the equipment to measure the actual maximum RPM.

Measuring RPM:

  1. To measure the RPM, an IR proximity sensor is used.
  2. The RPM of the object to measured, a wheel in my case, is covered by a black tape with a white spot on it. The white spot is needed to reflect the IR light which in turn triggers the output of the IR sensor.

Note:

The output of the IR sensor must be pulled up to VCC using a pull up resistor of 4.7K or so. This is because the IR sensor has an open collector output ,i.e, the output can only be pulled LOW so a pull up resistor is needed to avoid a floating pin. Refer to the connection diagram below: connection of IR sensor

ELECTRICAL CHARACTERISTICS:

Pin Voltage
Input 7.5V - 12V
PWM 5V
Frequency Counter 5V
dsb18b20 data pin 5V

USER INTERFACE:

To use the this device, we must be aware of the hardware as well as the software interface and that is what we will be covering in this section starting with the pinout.

PINOUT:

Seeing all those switches and connector might seem intimidating at first but don't you worry as that is what I will breaking down in this section.

pinout

Each connector and switch in the picture has been designated with a number to aid with it's identification in the table below:

Pin No Function
1 5V
2 GND
3 dsb18b20 data pin
4 Frequency counter
5 GND
6 PWM
7 BACK
8 UP / Increament
9 DOWN / Decreament
10 ENTER / SELECT
11 Power switch

HOW TO USE:

  • Connect a 9v battery and press the power button.
  • On startup you will be greated with the homescreen/menupage. menupage
  • The cursor on the right points to the current selected the option.
  • Use the UP and DOWN buttons to navigate through the menu.
  • Press the ENTER button to enter the menu or option.
  • Press the BACK button to exit from the current option.

That's the basic on how to use the meter. However taking a look at an example will provide a broader picture. Let's take the example of the PWM mode:

  • Press the DOWN switch to point the arrow at the PWM mode. PWM

  • Press ENTER to enter PWM mode. PWM_Range

  • Now, you will be greeted with the PWM frequency range menu. The PWM frequency range is subdivied into 4 ranges:

    Range Frequency Range
    1 31Hzへるつ - 1KHz
    2 1KHz - 10KHz
    3 10KHz - 40KHz
    4 40KHz - 100KHz
  • Let's select the first range(31HZ - 1KHz) by pressing ENTER. firstRange

  • Now you will be presented with 2 options and those are frequency(Freq:) and duty cycle (Duty%:). By default the frequency is set to the lowest value in the given range(31Hzへるつ in this case) while the duty cycle is set to to 50.

  • To change the default value, the frequency value in this case, press ENTER. freq_edit

  • Now the cursor shifts to the right hand side, implying that you are in the value edit mode.

  • Press the UP or DOWN button to either increament or decreament the values in single steps or long press the respective button to rapidly increase or decrease the value. changingFreq

  • Once you have set the desired value, press ENTER to save it and the cursor moves back to the left hand side. savingFreq

  • The same steps are applicable for changing the duty cycle value.

  • First, press the DOWN button to select duty cycle. dutyCycle

  • Now press ENTER to select it and the cursor moves to the right hand side implying you are in the value edit mode. dutyCycleSelected

  • Now change the value by either pressing the UP or DOWN button. The procedure is as the same as the one shown above for frequency. changingDutyCycle

  • Press ENTER to save the value. savedDutyCycle

  • To exit from the PWM menu, press the BACK button. PWM_Range

  • Press BACK again to get to the homescreen. PWM

DONE THIS IS IT!

This is all you need to know to get started using this meter.

Note:

  • The frequency and duty cycle change only upon pressing ENTER.
  • The frequency increment step is not 1Hzへるつ for every range. It changes with the frequency range. The table below shows the shows the frequecny range and it's increament/decreament step value:
Frequency Range Step Value
1 31Hzへるつ - 1KHz 1Hzへるつ
2 1KHz - 10KHz 10Hzへるつ
3 10KHz - 40KHz 100Hzへるつ
4 40KHz - 100KHz 1000Hzへるつ