-
First results of AUP Nb3Sn quadrupole horizontal tests
Authors:
M. Baldini,
G. Ambrosio,
G. Apollinari,
J. Blowers,
R. Bossert,
R. Carcagno,
G. Chlachidze,
J. DiMarco,
S. Feher,
S. Krave,
V. Lombardo,
L. Martin,
C. Narug,
T. H. Nicol,
V. Nikolic,
A. Nobrega,
V. Marinozzi,
C. Orozco,
T. Page,
S. Stoynev,
T. Strauss,
M. Turenne,
D. Turrioni,
A. Vouris,
M. Yu
, et al. (26 additional authors not shown)
Abstract:
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a…
▽ More
The Large Hadron Collider will soon undergo an upgrade to increase its luminosity by a factor of ~10 [1]. A crucial part of this upgrade will be replacement of the NbTi focusing magnets with Nb3Sn magnets that achieve a ~50% increase in the field strength. This will be the first ever large-scale implementation of Nb3Sn magnets in a particle accelerator. The High-Luminosity LHC Upgrade, HL-LHC is a CERN project with a world-wide collaboration. It is under construction and utilizes Nb3Sn Magnets (named MQXF) as key ingredients to increase tenfold the integrated luminosity delivered to the CMS and ATLAS experiments in the next decade.
The HL-LHC AUP is the US effort to contribute approximately 50% of the low-beta focusing magnets and crab cavities for the HL-LHC.
This paper will present the program to fabricate the Nb3Sn superconducting magnets. We are reporting the status of the HL-LHC AUP project present the results from horizontal tests of the first fully assembled cryo-assembly.
△ Less
Submitted 28 May, 2024;
originally announced May 2024.
-
MQXFA Series Magnet Production Specification
Authors:
Paolo Ferracin,
Giorgio Ambrosio,
Giorgio Apollinari,
James Blowers,
Ruben Carcagno,
Dan Cheng,
Katherine Ray,
Soren Prestemon,
Michael Solis,
Giorgio Vallone
Abstract:
The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA…
▽ More
The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA series magnets are based on the R&D performed by the US LHC Accelerator Research Program (LARP) and the development performed by AUP, in collaboration with CERN, through fabrication and test of pre-series coils and magnets.
△ Less
Submitted 25 January, 2023;
originally announced February 2023.
-
Challenges and Lessons Learned from fabrication, testing and analysis of eight MQXFA Low Beta Quadrupole magnets for HL-LHC
Authors:
G. Ambrosio,
K. Amm,
M. Anerella,
G. Apollinari,
G. Arnau Izquierdo,
M. Baldini,
A. Ballarino,
C. Barth,
A. Ben Yahia,
J. Blowers,
P. Borges De Sousa,
R. Bossert,
B. Bulat,
R. Carcagno,
D. W. Cheng,
G. Chlachidze,
L. Cooley,
M. Crouvizier,
A. Devred,
J. DiMarco,
S. Feher,
P. Ferracin,
J. Ferradas Troitino,
L. Garcia Fajardo,
S. Gourlay
, et al. (33 additional authors not shown)
Abstract:
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of th…
▽ More
By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some criteria and were disassembled. Lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this paper, we present a summary of: 1) the fabrication and test data of all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab
Authors:
T. Arkan,
J. Kaluzny,
D. Bafia,
D. Bice,
J. Blowers,
A. Cravatta,
M. Checchin,
B. Giaccone,
C. Grimm,
B. Hartsell,
M. Martinello,
T. Nicol,
Y. Orlov,
S. Posen
Abstract:
The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It…
▽ More
The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.
△ Less
Submitted 26 August, 2022;
originally announced August 2022.
-
MQXFA Final Design Report
Authors:
Giorgio Ambrosio,
Kathleen Amm,
Mike Anerella,
Giorgio Apollinari,
Maria Baldini,
Anis Ben Yahia,
James Blowers,
Ruben Carcagno,
Daniel Cheng,
Guram Chlachidze,
Lance Cooley,
Sandor Feher,
Paolo Ferracin,
Henry Hocker,
Susana Izquierdo Bermudez,
Piyush Joshi,
Vito Lombardo,
Vittorio Marinozzi,
Joseph Muratore,
Michael Naus,
Fred Nobrega,
Heng Pan,
Marcellus Parker,
Ian Pong,
Soren Prestemon
, et al. (7 additional authors not shown)
Abstract:
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, man…
▽ More
The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.
*Supported by the U.S. Department of Energy, Office of Science, Office of High Energy Physics
△ Less
Submitted 13 March, 2022;
originally announced March 2022.
-
Record fast-cycling accelerator magnet based on high temperature superconductors
Authors:
Henryk Piekarz,
Steven Hays,
Jamie Blowers,
Bradley Claypool,
Vladimir Shiltsev
Abstract:
Four decades ago development of high-current superconducting NbTi wire cables revolutionized the magnet technology for energy frontier accelerators, such as Tevatron, RHIC and LHC. The NbTi based magnets offered advantage of much higher fields B and much lower electric wall plug power consumption if operated at 4.5 K but relatively small ramping rates dB/dt << 0.1 T/s. The need for the accelerator…
▽ More
Four decades ago development of high-current superconducting NbTi wire cables revolutionized the magnet technology for energy frontier accelerators, such as Tevatron, RHIC and LHC. The NbTi based magnets offered advantage of much higher fields B and much lower electric wall plug power consumption if operated at 4.5 K but relatively small ramping rates dB/dt << 0.1 T/s. The need for the accelerators of high average beam power and high repetition rates have initiated studies of fast ramping SC magnets, but it was found the AC losses in the low-temperature superconductors preclude obtaining the rates in the excess of (1- 4) T/s. Here we report the first application of high-temperature superconductor magnet technology with substantially lower AC losses and report record high ramping rates of 12 T/s achieved in a prototype dual-aperture accelerator magnet.
△ Less
Submitted 9 March, 2019;
originally announced March 2019.
-
Design, Construction and Test Arrangement of a Fast-Cycling HTS Accelerator Magnet
Authors:
H. Piekarz,
Jamie Blowers,
Steven Hays,
Vladimir Shiltsev
Abstract:
Design, fabrication and assembly of a novel fast-cycling accelerator magnet is presented. A short-sample magnet is powered with a single-turn HTS cable capable to carry 80 kA current at 20 K and generate 1.75 T field in a 40 mm magnet gap. The applied conventional leads and the power supply, however, allow only for a sin-wave 24 kA, 20 Hz current limiting test magnet to a B-field of 0.5 T and to a…
▽ More
Design, fabrication and assembly of a novel fast-cycling accelerator magnet is presented. A short-sample magnet is powered with a single-turn HTS cable capable to carry 80 kA current at 20 K and generate 1.75 T field in a 40 mm magnet gap. The applied conventional leads and the power supply, however, allow only for a sin-wave 24 kA, 20 Hz current limiting test magnet to a B-field of 0.5 T and to a maximum cycling rate of 20 T/s. The critical aspects of the cable construction and the splicing connection to the power leads are described. Tentative power losses of the proposed HTS accelerator magnet in a possible application for proton and muon accelerators are presented.
△ Less
Submitted 19 September, 2014;
originally announced September 2014.
-
A Test of HTS Power Cable in a Sweeping Magnetic Field
Authors:
H. Piekarz,
S. Hays,
J. Blowers,
V. Shiltsev
Abstract:
Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s rate. The B-field orientation toward the HTS strands wide surface was varied from 0 deg. to 10 deg., in steps of 1 deg.. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. F…
▽ More
Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s rate. The B-field orientation toward the HTS strands wide surface was varied from 0 deg. to 10 deg., in steps of 1 deg.. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. For the validity of these measurements, the power losses of a short sample cable composed of multiple LTS wire strands were also performed to compare with the known data. The test arrangement of the power cable is described, and the test results are compared with the projections for the eddy and hysteresis power losses using the fine details of the test cable structures.
△ Less
Submitted 24 January, 2012;
originally announced January 2012.