The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
The Design, Construction, and Commissioning of the KATRIN Experiment
Authors:
M. Aker,
K. Altenmüller,
J. F. Amsbaugh,
M. Arenz,
M. Babutzka,
J. Bast,
S. Bauer,
H. Bechtler,
M. Beck,
A. Beglarian,
J. Behrens,
B. Bender,
R. Berendes,
A. Berlev,
U. Besserer,
C. Bettin,
B. Bieringer,
K. Blaum,
F. Block,
S. Bobien,
J. Bohn,
K. Bokeloh,
H. Bolz,
B. Bornschein,
L. Bornschein
, et al. (204 additional authors not shown)
Abstract:
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goa…
▽ More
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) [https://publikationen.bibliothek.kit.edu/270060419] to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90% C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating [arXiv:1909.06048]. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times, and present details on their respective commissioning campaigns.
△ Less
Submitted 11 June, 2021; v1 submitted 5 March, 2021;
originally announced March 2021.
-
Beta decay of molecular tritium
Authors:
Y. -T. Lin,
T. H. Burritt,
C. Claessens,
G. Holman,
M. Kallander,
E. Machado,
L. I. Minter,
R. Ostertag,
D. S. Parno,
J. Pedersen,
D. A. Peterson,
R. G. H. Robertson,
E. B. Smith,
T. D. Van Wechel,
A. P. Vizcaya Hernández
Abstract:
The beta decay of tritium in the form of molecular TT is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the beta spectrum significantly, and are obtained from theory. We report measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave br…
▽ More
The beta decay of tritium in the form of molecular TT is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the beta spectrum significantly, and are obtained from theory. We report measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave branching ratios of HT to the bound HHe$^+$ ion of 89.5% and 93.2%, in sharp disagreement with the theoretical prediction of 55-57%, raising concerns about the theory's reliability in neutrino mass experiments. Our result, 56.5(6)%, is compatible with the theoretical expectation and disagrees strongly with the previous measurements.
△ Less
Submitted 24 May, 2020; v1 submitted 31 January, 2020;
originally announced January 2020.
-
Commissioning of the vacuum system of the KATRIN Main Spectrometer
Authors:
M. Arenz,
M. Babutzka,
M. Bahr,
J. P. Barrett,
S. Bauer,
M. Beck,
A. Beglarian,
J. Behrens,
T. Bergmann,
U. Besserer,
J. Blümer,
L. I. Bodine,
K. Bokeloh,
J. Bonn,
B. Bornschein,
L. Bornschein,
S. Büsch,
T. H. Burritt,
S. Chilingaryan,
T. J. Corona,
L. De Viveiros,
P. J. Doe,
O. Dragoun,
G. Drexlin,
S. Dyba
, et al. (125 additional authors not shown)
Abstract:
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong m…
▽ More
The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
△ Less
Submitted 3 March, 2016;
originally announced March 2016.
-
Focal-plane detector system for the KATRIN experiment
Authors:
J. F. Amsbaugh,
J. Barrett,
A. Beglarian,
T. Bergmann,
H. Bichsel,
L. I. Bodine,
J. Bonn,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
S. Chilingaryan,
T. J. Corona,
P. J. Doe,
J. A. Dunmore,
S. Enomoto,
J. Fischer,
J. A. Formaggio,
F. M. Fränkle,
D. Furse,
H. Gemmeke,
F. Glück,
F. Harms,
G. C. Harper,
J. Hartmann,
M. A. Howe
, et al. (26 additional authors not shown)
Abstract:
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro…
▽ More
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
△ Less
Submitted 28 January, 2015; v1 submitted 10 April, 2014;
originally announced April 2014.
-
Dead layer on silicon p-i-n diode charged-particle detectors
Authors:
B. L. Wall,
J. F. Amsbaugh,
A. Beglarian,
T. Bergmann,
H. C. Bichsel,
L. I. Bodine,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
T. J. Corona,
P. J. Doe,
S. Enomoto,
F. Harms,
G. C. Harper,
M. A. Howe,
E. L. Martin,
D. S. Parno,
D. A. Peterson,
L. Petzold,
P. Renschler,
R. G. H. Robertson,
J. Schwarz,
M. Steidl,
T. D. Van Wechel,
B. A. VanDevender
, et al. (3 additional authors not shown)
Abstract:
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-…
▽ More
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
△ Less
Submitted 7 October, 2013; v1 submitted 4 October, 2013;
originally announced October 2013.
-
Alpha Backgrounds for HPGe Detectors in Neutrinoless Double-Beta Decay Experiments
Authors:
R. A. Johnson,
T. H. Burritt,
S. R. Elliott,
V. M. Gehman,
V. E. Guiseppe,
J. F. Wilkerson
Abstract:
The Majorana Experiment will use arrays of enriched HPGe detectors to search for the neutrinoless double-beta decay of 76Ge. Such a decay, if found, would show lepton-number violation and confirm the Majorana nature of the neutrino. Searches for such rare events are hindered by obscuring backgrounds which must be understood and mitigated as much as possible. A potentially important background cont…
▽ More
The Majorana Experiment will use arrays of enriched HPGe detectors to search for the neutrinoless double-beta decay of 76Ge. Such a decay, if found, would show lepton-number violation and confirm the Majorana nature of the neutrino. Searches for such rare events are hindered by obscuring backgrounds which must be understood and mitigated as much as possible. A potentially important background contribution to this and other double-beta decay experiments could come from decays of alpha-emitting isotopes in the 232Th and 238U decay chains on or near the surfaces of the detectors. An alpha particle emitted external to an HPGe crystal can lose energy before entering the active region of the detector, either in some external-bulk material or within the dead region of the crystal. The measured energy of the event will only correspond to a partial amount of the total kinetic energy of the alpha and might obscure the signal from neutrinoless double-beta decay. A test stand was built and measurements were performed to quantitatively assess this background. We present results from these measurements and compare them to simulations using Geant4. These results are then used to measure the alpha backgrounds in an underground detector in situ. We also make estimates of surface contamination tolerances for double-beta decay experiments using solid-state detectors.
△ Less
Submitted 30 December, 2011;
originally announced January 2012.
-
Measurement of the $ν_e$ and Total $^{8}$B Solar Neutrino Fluxes with the Sudbury Neutrino Observatory Phase-III Data Set
Authors:
B. Aharmim,
S. N. Ahmed,
J. F. Amsbaugh,
J. M. Anaya,
A. E. Anthony,
J. Banar,
N. Barros,
E. W. Beier,
A. Bellerive,
B. Beltran,
M. Bergevin,
S. D. Biller,
K. Boudjemline,
M. G. Boulay,
T. J. Bowles,
M. C. Browne,
T. V. Bullard,
T. H. Burritt,
B. Cai,
Y. D. Chan,
D. Chauhan,
M. Chen,
B. T. Cleveland,
G. A. Cox,
C. A. Currat
, et al. (125 additional authors not shown)
Abstract:
This paper details the solar neutrino analysis of the 385.17-day Phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of $^3$He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active $^8$B solar neutrino flux was largely independent of the…
▽ More
This paper details the solar neutrino analysis of the 385.17-day Phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of $^3$He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active $^8$B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be $5.54^{+0.33}_{-0.31}(stat.)^{+0.36}_{-0.34}(syst.)\times 10^{6}$ cm$^{-2}$ s$^{-1}$, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of $Δm^2 = 7.59^{+0.19}_{-0.21}\times 10^{-5}{eV}^2$ and $θ= 34.4^{+1.3}_{-1.2}$ degrees.
△ Less
Submitted 14 July, 2011;
originally announced July 2011.
-
Four methods for determining the composition of trace radioactive surface contamination of low-radioactivity metal
Authors:
H. M. O'Keeffe,
T. H. Burritt,
B. T. Cleveland,
G. Doucas,
N. Gagnon,
N. A. Jelley,
C. Kraus,
I. T. Lawson,
S. Majerus,
S. R. McGee,
A. W. Myers,
A. W. P. Poon,
K. Rielage,
R. G. H. Robertson,
R. C. Rosten,
L. C. Stonehill,
B. A. VanDevender,
T. D. Van Wechel
Abstract:
Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive proportional counter surrounding the surface is used to make both a measurement of the energy spectrum of alpha particle emissions and also coincidence measureme…
▽ More
Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive proportional counter surrounding the surface is used to make both a measurement of the energy spectrum of alpha particle emissions and also coincidence measurements to derive the thorium-chain content based on the presence of short-lived isotopes in that decay chain. The fourth method is a radiochemical technique in which the surface is eluted with a weak acid, the eluate is concentrated, added to liquid scintillator and assayed by recording beta-alpha coincidences. These methods were used to characterize two `hotspots' on the outer surface of one of the He-3 proportional counters in the Neutral Current Detection array of the Sudbury Neutrino Observatory experiment. The methods have similar sensitivities, of order tens of ng, to both thorium- and uranium-chain contamination.
△ Less
Submitted 29 March, 2011;
originally announced March 2011.
-
Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector
Authors:
MAJORANA Collaboration,
C. E. Aalseth,
M. Amman,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
M. Bergevin,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
W. Bugg,
T. H. Burritt,
M. Busch,
G. Capps,
Y-D. Chan,
J. I. Collar,
R. J. Cooper,
R. Creswick,
J. A. Detwiler,
J. Diaz,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri
, et al. (78 additional authors not shown)
Abstract:
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in t…
▽ More
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.
△ Less
Submitted 20 July, 2010; v1 submitted 19 July, 2010;
originally announced July 2010.
-
An array of low-background $^3$He proportional counters for the Sudbury Neutrino Observatory
Authors:
J. F. Amsbaugh,
J. M. Anaya,
J. Banar,
T. J. Bowles,
M. C. Browne,
T. V. Bullard,
T. H. Burritt,
G. A. Cox-Mobrand,
X. Dai,
H. Deng,
M. Di Marco,
P. J. Doe,
M. R. Dragowsky,
C. A. Duba,
F. A. Duncan,
E. D. Earle,
S. R. Elliott,
E. -I. Esch,
H. Fergani,
J. A. Formaggio,
M. M. Fowler,
J. E. Franklin,
P. Geissbühler,
J. V. Germani,
A. Goldschmidt
, et al. (49 additional authors not shown)
Abstract:
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consis…
▽ More
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consisted of 36 strings of proportional counters filled with a mixture of $^3$He and CF$_4$ gas capable of detecting the neutrons liberated by the neutrino-deuteron neutral current reaction in the D$_2$O, and four strings filled with a mixture of $^4$He and CF$_4$ gas for background measurements. The proportional counter diameter is 5 cm. The total deployed array length was 398 m. The SNO NCD array is the lowest-radioactivity large array of proportional counters ever produced. This article describes the design, construction, deployment, and characterization of the NCD array, discusses the electronics and data acquisition system, and considers event signatures and backgrounds.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.