A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
Authors:
CUPID collaboration,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
A. Campani,
C. Capelli
, et al. (154 additional authors not shown)
Abstract:
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of…
▽ More
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of $^{100}$Mo-enriched Li$_2$MoO$_4$ crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70--90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained outstanding energy resolutions at the 356 keV line from a $^{133}$Ba source with one light detector achieving 0.71(5) keV FWHM, which is -- to our knowledge -- the best ever obtained when compared to $γ$ detectors of any technology in this energy range.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments
Authors:
CUPID,
CROSS collaborations,
:,
K. Alfonso,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
V. Berest,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci
, et al. (160 additional authors not shown)
Abstract:
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied…
▽ More
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, $μ$Bq/kg, level of the LMO crystals radioactive contamination by $^{228}$Th and $^{226}$Ra.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
-
Disentangling the sources of ionizing radiation in superconducting qubits
Authors:
L. Cardani,
I. Colantoni,
A. Cruciani,
F. De Dominicis,
G. D'Imperio,
M. Laubenstein,
A. Mariani,
L. Pagnanini,
S. Pirro,
C. Tomei,
N. Casali,
F. Ferroni,
D. Frolov,
L. Gironi,
A. Grassellino,
M. Junker,
C. Kopas,
E. Lachman,
C. R. H. McRae,
J. Mutus,
M. Nastasi,
D. P. Pappas,
R. Pilipenko,
M. Sisti,
V. Pettinacci
, et al. (5 additional authors not shown)
Abstract:
Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and gamma's emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly an…
▽ More
Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and gamma's emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We develop a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.
△ Less
Submitted 24 November, 2022;
originally announced November 2022.
-
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
Authors:
The NUCLEUS collaboration,
C. Goupy,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
A. Doblhammer,
S. Dorer,
A. Erhart,
M. Friendl,
A. Garai,
V. M. Ghete,
D. Hauff,
F. Jeanneau,
E. Jericha,
M. Kaznacheeva,
A. Kinast
, et al. (37 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for…
▽ More
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS is a unique process to study neutrino properties and to search for physics beyond the Standard Model. The study of CEvNS is also important for light Dark-Matter searches. It could be a possible irreducible background for high-sensitivity Dark-Matter searches. NUCLEUS is an experiment under construction based on ultra-low threshold (20 eVnr) cryogenic calorimeters, operated at tens-of-mK temperatures.
△ Less
Submitted 10 November, 2022; v1 submitted 8 November, 2022;
originally announced November 2022.
-
Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture
Authors:
CRAB Collaboration,
NUCLEUS Collaboration,
H. Abele,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
A. Chalil,
A. Chebboubi,
I. Colantoni,
J. -P. Crocombette,
A. Cruciani,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Desforge,
A. Doblhammer,
E. Dumonteil,
S. Dorer,
A. Erhart,
A. Fuss,
M. Friedl,
A. Garai
, et al. (53 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact…
▽ More
Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.
△ Less
Submitted 2 June, 2023; v1 submitted 7 November, 2022;
originally announced November 2022.
-
BULLKID: Monolithic array of particle absorbers sensed by Kinetic Inductance Detectors
Authors:
A. Cruciani,
L. Bandiera,
M. Calvo,
N. Casali,
I. Colantoni,
G. Del Castello,
M. del Gallo Roccagiovine,
D. Delicato,
M. Giammei,
V. Guidi,
J. Goupy,
V. Pettinacci,
G. Pettinari,
M. Romagnoni,
M. Tamisari,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prot…
▽ More
We introduce BULLKID, an innovative phonon detector consisting of an array of dices acting as particle absorbers sensed by multiplexed Kinetic Inductance Detectors (KIDs). The dices are carved in a thick crystalline wafer and form a monolithic structure. The carvings leave a thin common disk intact in the wafer, acting both as holder for the dices and as substrate for the KID lithography. The prototype presented consists of an array of 64 dices of 5.4x5.4x5 mm$^3$ carved in a 3" diameter, 5 mm thick silicon wafer, with a common disk 0.5 mm thick hosting a 60 nm patterned aluminum layer. The resulting array is highly segmented but avoids the use of dedicated holding structures for each unit. Despite the fact that the uniformity of the KID electrical response across the array needs optimization, the operation of 8 units with similar features shows, on average, a baseline energy resolution of $26\pm7$ eV. This makes it a suitable detector for low-energy processes such as direct interactions of dark matter and coherent elastic neutrino-nucleus scattering.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
Search for Majoron-like particles with CUPID-0
Authors:
CUPID-0 Collaboration,
:,
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
E. Celi,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
S. Di Domizio,
V. Dompè,
G. Fantini
, et al. (29 additional authors not shown)
Abstract:
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the…
▽ More
We present the first search for the Majoron-emitting modes of the neutrinoless double $β$ decay ($0νββχ_0$) using scintillating cryogenic calorimeters. We analysed the CUPID-0 Phase I data using a Bayesian approach to reconstruct the background sources activities, and evaluate the potential contribution of the $^{82}$Se $0νββχ_0$. We considered several possible theoretical models which predict the existence of a Majoron-like boson coupling to the neutrino. The energy spectra arising from the emission of such bosons in the neutrinoless double $β$ decay have spectral indices $n=$ 1, 2, 3 or 7. We found no evidence of any of these decay modes, setting a lower limit (90% of credibility interval) on the half-life of 1.2 $\times$ 10$^{23}$ yr in the case of $n=$ 1, 3.8 $\times$ 10$^{22}$ yr for $n=$ 2, 1.4 $\times$ 10$^{22}$ yr for $n=$ 3 and 2.2 $\times$ 10$^{21}$ yr for $n=$ 7. These are the best limits on the $0νββχ_0$ half-life of the $^{82}$Se, and demonstrate the potentiality of the CUPID-0 technology in this field.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Final Result on the Neutrinoless Double Beta Decay of $^{82}$Se with CUPID-0
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
V. Caracciolo,
L. Cardani,
P. Carniti,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
A. D'Addabbo,
I. Dafinei,
F. De Dominics,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla
, et al. (23 additional authors not shown)
Abstract:
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last…
▽ More
CUPID-0, an array of Zn$^{82}$Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers technology. The first project phase (March 2017 - December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, $^{82}$Se, to be set. After a six months long detector upgrade, CUPID-0 began its second and last phase (June 2019 - February 2020). In this letter, we describe the search for neutrinoless double beta decay of $^{82}$Se with a total exposure (phase I + II) of 8.82 kg$\times$yr of isotope. We set a limit on the half-life of $^{82}$Se to the ground state of $^{82}$Kr of T$^{0ν}_{1/2}$($^{82}$Se)$>$ 4.6$\times \mathrm{10}^{24}$ yr (90\% credible interval), corresponding to an effective Majorana neutrino mass m$_{ββ} <$ (263 -- 545) meV. We also set the most stringent lower limits on the neutrinoless decays of $^{82}$Se to the 0$_1^+$, 2$_1^+$ and 2$_2^+$ excited states of $^{82}$Kr, finding 1.8$\times$10$^{23}$ yr, 3.0$\times$10$^{23}$ yr, 3.2$\times$10$^{23}$ yr (90$\%$ credible interval) respectively.
△ Less
Submitted 10 June, 2022;
originally announced June 2022.
-
Optimization of the first CUPID detector module
Authors:
CUPID collaboration,
A. Armatol,
C. Augier,
F. T. Avignone III,
O. Azzolini,
M. Balata,
K. Ballen,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
M. Bettelli,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
C. Capelli,
S. Capelli,
L. Cappelli
, et al. (153 additional authors not shown)
Abstract:
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the…
▽ More
CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.
△ Less
Submitted 13 February, 2022;
originally announced February 2022.
-
EXCESS workshop: Descriptions of rising low-energy spectra
Authors:
P. Adari,
A. Aguilar-Arevalo,
D. Amidei,
G. Angloher,
E. Armengaud,
C. Augier,
L. Balogh,
S. Banik,
D. Baxter,
C. Beaufort,
G. Beaulieu,
V. Belov,
Y. Ben Gal,
G. Benato,
A. Benoît,
A. Bento,
L. Bergé,
A. Bertolini,
R. Bhattacharyya,
J. Billard,
I. M. Bloch,
A. Botti,
R. Breier,
G. Bres,
J-. L. Bret
, et al. (281 additional authors not shown)
Abstract:
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was…
▽ More
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
△ Less
Submitted 4 March, 2022; v1 submitted 10 February, 2022;
originally announced February 2022.
-
Development of a compact muon veto for the NUCLEUS experiment
Authors:
V. Wagner,
R. Rogly,
A. Erhart,
V. Savu,
C. Goupy,
D. Lhuillier,
M. Vivier,
L. Klinkenberg,
G. Angloher,
A. Bento,
L. Canonica,
F. Cappella,
L. Cardani,
N. Casali,
R. Cerulli,
I. Colantoni,
A. Cruciani,
G. del Castello,
M. Friedl,
A. Garai,
V. M. Ghete,
V. Guidi,
D. Hauff,
M. Kaznacheeva,
A. Kinast
, et al. (30 additional authors not shown)
Abstract:
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spati…
▽ More
The NUCLEUS experiment aims to measure coherent elastic neutrino nucleus scattering of reactor anti-neutrinos using cryogenic calorimeters. Operating at an overburden of 3 m.w.e., muon-induced backgrounds are expected to be one of the dominant background contributions. Besides a high efficiency to identify muon events passing the experimental setup, the NUCLEUS muon veto has to fulfill tight spatial requirements to fit the constraints given by the experimental site and to minimize the induced detector dead-time. We developed highly efficient and compact muon veto modules based on plastic scintillators equipped with wavelength shifting fibers and silicon photo multipliers to collect and detect the scintillation light. In this paper, we present the full characterization of a prototype module with different light read-out configurations. We conclude that an efficient and compact muon veto system can be built for the NUCLEUS experiment from a cube assembly of the developed modules. Simulations show that an efficiency for muon identification of >99 % and an associated rate of 325 Hz is achievable, matching the requirements of the NUCLEUS experiment.
△ Less
Submitted 26 April, 2022; v1 submitted 8 February, 2022;
originally announced February 2022.
-
Measurement of $^{216}$Po half-life with the CUPID-0 experiment
Authors:
O. Azzolini,
J. W. Beeman,
F. Bellini,
M. Beretta,
M. Biassoni,
C. Brofferio,
C. Bucci,
S. Capelli,
L. Cardani,
P. Carniti,
V. Caracciolo,
N. Casali,
D. Chiesa,
M. Clemenza,
I. Colantoni,
O. Cremonesi,
A. Cruciani,
I. Dafinei,
A. D'Addabbo,
S. Di Domizio,
F. Ferroni,
L. Gironi,
A. Giuliani,
P. Gorla,
C. Gotti
, et al. (22 additional authors not shown)
Abstract:
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited ex…
▽ More
Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.
△ Less
Submitted 12 May, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
Final results of CALDER: Kinetic inductance light detectors to search for rare events
Authors:
Laura Cardani,
Nicola Casali,
Ivan Colantoni,
Angelo Cruciani,
Sergio Di Domizio,
Maria Martinez,
Valerio Pettinacci,
Giorgio Pettinari,
Marco Vignati
Abstract:
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020) developed a new technology for light detection at cryogenic temperature. In this paper we describe the achievements and the final prototype of this project, consisting…
▽ More
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020) developed a new technology for light detection at cryogenic temperature. In this paper we describe the achievements and the final prototype of this project, consisting of a $5\times5$ cm$^2$, 650 $μ$m thick silicon substrate coupled to a single kinetic inductance detector made of a three-layer aluminum-titanium-aluminum. The baseline energy resolution is 34$\pm$1(stat)$\pm$2(syst) eV RMS and the response time is 120 $μ$s. These features, along with the natural multiplexing capability of kinetic inductance detectors, meet the requirements of future large-scale experiments.
△ Less
Submitted 14 April, 2021;
originally announced April 2021.
-
Non-linearity in the system of quasiparticles of a superconducting resonator
Authors:
M. Vignati,
C. Bellenghi,
L. Cardani,
N. Casali,
I. Colantoni,
A. Cruciani
Abstract:
We observed a strong non-linearity in the system of quasiparticles of a superconducting aluminum resonator, due to the Cooper-pair breaking from the absorbed readout power. We observed both negative and positive feedback effects, controlled by the detuning of the readout frequency, which are able to alter the relaxation time of quasiparticles by a factor greater than 10. We estimate that the (70+/…
▽ More
We observed a strong non-linearity in the system of quasiparticles of a superconducting aluminum resonator, due to the Cooper-pair breaking from the absorbed readout power. We observed both negative and positive feedback effects, controlled by the detuning of the readout frequency, which are able to alter the relaxation time of quasiparticles by a factor greater than 10. We estimate that the (70+/-5) % of the total non-linearity of the device is due to quasiparticles.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Novel technique for the study of pile-up events in cryogenic bolometers
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (144 additional authors not shown)
Abstract:
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our ap…
▽ More
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15ms down to time separation between the individual events of about 2ms.
△ Less
Submitted 12 July, 2021; v1 submitted 23 November, 2020;
originally announced November 2020.
-
Reducing the impact of radioactivity on quantum circuits in a deep-underground facility
Authors:
Laura Cardani,
Francesco Valenti,
Nicola Casali,
Gianluigi Catelani,
Thibault Charpentier,
Massimiliano Clemenza,
Ivan Colantoni,
Angelo Cruciani,
Luca Gironi,
Lukas Grünhaupt,
Daria Gusenkova,
Fabio Henriques,
Marc Lagoin,
Maria Martinez,
Giorgio Pettinari,
Claudia Rusconi,
Oliver Sander,
Alexey V. Ustinov,
Marc Weber,
Wolfgang Wernsdorfer,
Marco Vignati,
Stefano Pirro,
Ioan M. Pop
Abstract:
As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of…
▽ More
As quantum coherence times of superconducting circuits have increased from nanoseconds to hundreds of microseconds, they are currently one of the leading platforms for quantum information processing. However, coherence needs to further improve by orders of magnitude to reduce the prohibitive hardware overhead of current error correction schemes. Reaching this goal hinges on reducing the density of broken Cooper pairs, so-called quasiparticles. Here, we show that environmental radioactivity is a significant source of nonequilibrium quasiparticles. Moreover, ionizing radiation introduces time-correlated quasiparticle bursts in resonators on the same chip, further complicating quantum error correction. Operating in a deep-underground lead-shielded cryostat decreases the quasiparticle burst rate by a factor fifty and reduces dissipation up to a factor four, showcasing the importance of radiation abatement in future solid-state quantum hardware.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
In-flight performance of the LEKIDs of the OLIMPO experiment
Authors:
A. Paiella,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
S. Gordon,
L. Lamagna,
C. Magneville,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Polenta,
G. Presta,
E. Tommasi,
C. Tucker,
V. Vdovin,
A. Volpe,
D. Yvon
Abstract:
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the firs…
▽ More
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the first hours of flight, we tuned the detectors and verified their large dynamics under the radiative background variations due to elevation increase of the telescope and to the insertion of the plug-in room-temperature differential Fourier transform spectrometer into the optical chain. We have found that the detector noise equivalent powers are close to be photon-noise limited and lower than those measured on the ground. Moreover, the data contamination due to primary cosmic rays hitting the arrays is less than 3% for all the pixels of all the arrays, and less than 1% for most of the pixels. These results can be considered the first step of KID technology validation in a representative space environment.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Phonon and light read out of a Li$_2$MoO$_4$ crystal with multiplexed kinetic inductance detectors
Authors:
N. Casali,
L. Cardani,
I. Colantoni,
A. Cruciani,
S. Di Domizio,
M. Martinez,
G. Pettinari,
M. Vignati
Abstract:
Molybdenum based crystals such as Li$_2$MoO$_4$ and CaMoO$_4$ are emerging as leading candidates for next generation experiments searching for neutrino-less double beta decay with cryogenic calorimeters (CUPID, AMoRE). The exquisite energy resolution and high radio-purity of these crystals come at the cost of a potentially detrimental background source: the two neutrinos double beta decay of…
▽ More
Molybdenum based crystals such as Li$_2$MoO$_4$ and CaMoO$_4$ are emerging as leading candidates for next generation experiments searching for neutrino-less double beta decay with cryogenic calorimeters (CUPID, AMoRE). The exquisite energy resolution and high radio-purity of these crystals come at the cost of a potentially detrimental background source: the two neutrinos double beta decay of $^{100}$Mo. Indeed, the fast half-life of this decay mode, combined with the slow response of cryogenic calorimeters, would result in pile-up events in the energy region of interest for neutrino-less double beta decay, reducing the experimental sensitivity. This background can be suppressed using fast and high sensitivity cryogenic light detectors, provided that the scintillation time constant itself does not limit the time resolution. We developed a new detection technique exploiting the high sensitivity, the fast time response and the multiplexing capability of Kinetic Inductance Detectors. We applied the proposed technique to a $2\times2\times2$ cm$^3$ Li$_2$MoO$_4$ crystal, which was chosen as baseline option for CUPID. We measured simultaneously both the phonon and scintillation signals with KIDs. We derived the scintillation time constant of this compound at millikelvin temperatures obtaining $τ_{scint} = 84.5\pm4.5\rm{(syst)}\pm1.0\rm{(stat)}$ $μ$s, constant between 10 and 190 mK.
△ Less
Submitted 22 August, 2019; v1 submitted 8 July, 2019;
originally announced July 2019.
-
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Authors:
A. Paiella,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
L. Lamagna,
H. Mani,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Presta
Abstract:
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is ai…
▽ More
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
△ Less
Submitted 3 April, 2019;
originally announced April 2019.
-
Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization
Authors:
A. Paiella,
A. Coppolecchia,
L. Lamagna,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Presta,
C. Tucker
Abstract:
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environ…
▽ More
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460$\:$GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300$\:$mK. The measured average resonator $Q$s are 1.7$\times{10^4}$, 7.0$\times{10^4}$, 1.0$\times{10^4}$, and 1.0$\times{10^4}$ for the 150, 250, 350, and 460$\:$GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4$\:$rad/pW, 1.5$\:$rad/pW, 2.1$\:$rad/pW, and 2.1$\:$rad/pW; the electrical noise equivalent powers are 45$\:\rm{aW/\sqrt{Hz}}$, 160$\:\rm{aW/\sqrt{Hz}}$, 80$\:\rm{aW/\sqrt{Hz}}$, and 140$\:\rm{aW/\sqrt{Hz}}$, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NET$_{\rm RJ}$s are $200\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, and $\:340μ\rm{K\sqrt{s}}$, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
△ Less
Submitted 3 April, 2019; v1 submitted 1 October, 2018;
originally announced October 2018.
-
Ultra High Molecular Weight Polyethylene: optical features at millimeter wavelengths
Authors:
G. D'Alessandro,
A. Paiella,
A. Coppolecchia,
M. G. Castellano,
I. Colantoni,
P. de Bernardis,
L. Lamagna,
S. Masi
Abstract:
The next generation of experiments for the measurement of the Cosmic Microwave Background (CMB) requires more and more the use of advanced materials, with specific physical and structural properties. An example is the material used for receiver's cryostat windows and internal lenses. The large throughput of current CMB experiments requires a large diameter (of the order of 0.5m) of these parts, re…
▽ More
The next generation of experiments for the measurement of the Cosmic Microwave Background (CMB) requires more and more the use of advanced materials, with specific physical and structural properties. An example is the material used for receiver's cryostat windows and internal lenses. The large throughput of current CMB experiments requires a large diameter (of the order of 0.5m) of these parts, resulting in heavy structural and optical requirements on the material to be used. Ultra High Molecular Weight (UHMW) polyethylene (PE) features high resistance to traction and good transmissivity in the frequency range of interest. In this paper, we discuss the possibility of using UHMW PE for windows and lenses in experiments working at millimeter wavelengths, by measuring its optical properties: emissivity, transmission and refraction index. Our measurements show that the material is well suited to this purpose.
△ Less
Submitted 14 March, 2018;
originally announced March 2018.
-
Al/Ti/Al phonon-mediated KIDs for UV-VIS light detection over large areas
Authors:
L. Cardani,
N. Casali,
A. Cruciani,
H. le Sueur,
M. Martinez,
F. Bellini,
M. Calvo,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. D'Addabbo,
S. Di Domizio,
J. Goupy,
L. Minutolo,
A. Monfardini,
M. Vignati
Abstract:
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their…
▽ More
The development of wide-area cryogenic light detectors with baseline energy resolution lower than 20 eV RMS is essential for next generation bolometric experiments searching for rare interactions. Indeed the simultaneous readout of the light and heat signals will enable background suppression through particle identification. Because of their excellent intrinsic energy resolution, as well as their well-established reproducibility, Kinetic Inductance Detectors (KIDs) are good candidates for the development of next generation light detectors. The CALDER project is investigating the potential of phonon-mediated KIDs. The first phase of the project allowed to reach a baseline resolution of 80 eV using a single KID made of aluminium on a 2x2 cm\tmrsup{$2$} silicon substrate acting as photon absorber. In this paper we present a new prototype detector implementing a trilayer aluminium-titanium-aluminium KID. Taking advantage of the superconducting proximity effect the baseline resolution improves down to 26 eV.
△ Less
Submitted 27 April, 2018; v1 submitted 25 January, 2018;
originally announced January 2018.
-
High-sensitivity Kinetic Inductance Detectors for CALDER
Authors:
A. D'Addabbo,
F. Bellini,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. Cruciani,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors allows simultaneous read-out of the light and heat signals and enables background suppression through particle identification. The Cryogenic wide- Area Light Dete…
▽ More
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors allows simultaneous read-out of the light and heat signals and enables background suppression through particle identification. The Cryogenic wide- Area Light Detector with Excellent Resolution (CALDER) R&D already proved the potential of this technique using the phonon-mediated Kinetic Inductance Detectors (KIDs) approach. The first array prototype with 4 Aluminum KIDs on a 2 $\times$ 2 cm2 Silicon substrate showed a baseline resolution of 154 $\pm$ 7 eV RMS. Improving the design and the readout of the resonator, the next CALDER prototype featured an energy resolution of 82 $\pm$ 4 eV, by sampling the same substrate with a single Aluminum KID.
△ Less
Submitted 12 May, 2017;
originally announced May 2017.
-
Exploring Cosmic Origins with CORE: The Instrument
Authors:
P. de Bernardis,
P. A. R. Ade,
J. J. A. Baselmans,
E. S. Battistelli,
A. Benoit,
M. Bersanelli,
A. Bideaud,
M. Calvo,
F. J. Casas,
G. Castellano,
A. Catalano,
I. Charles,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
M. Crook,
G. D'Alessandro,
M. De Petris,
J. Delabrouille,
S. Doyle,
C. Franceschet,
A. Gomez,
J. Goupy,
S. Hanany,
M. Hills
, et al. (104 additional authors not shown)
Abstract:
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffr…
▽ More
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a precise and accurate measurement of the polarization of the Cosmic Microwave Background. The instrument is optimized to be compatible with the strict budget requirements of a medium-size space mission within the Cosmic Vision Programme of the European Space Agency. The instrument has no moving parts, and uses arrays of diffraction-limited Kinetic Inductance Detectors to cover the frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction of the CMB signal from polarized foreground emission. The projected CMB polarization survey sensitivity of this instrument, after foregrounds removal, is 1.7 μK$\cdot$arcmin. The design is robust enough to allow, if needed, a downscoped version of the instrument covering the 100 GHz to 600 GHz range with a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization survey sensitivity of 3.2 μK$\cdot$arcmin.
△ Less
Submitted 22 May, 2017; v1 submitted 5 May, 2017;
originally announced May 2017.
-
High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
Authors:
F. Bellini,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed K…
▽ More
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.
△ Less
Submitted 14 December, 2016; v1 submitted 14 June, 2016;
originally announced June 2016.
-
New application of superconductors: high sensitivity cryogenic light detectors
Authors:
L. Cardani,
F. Bellini,
N. Casali,
M. G. Casellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superc…
▽ More
In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2x2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.
△ Less
Submitted 12 April, 2016;
originally announced April 2016.
-
CALDER: cryogenic light detector for rare events search
Authors:
L. Pagnanini,
E. S. Battistelli,
F. Bellini,
M. Calvo,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
P. De Bernardis,
S. Di Domizio,
A. D'Addabbo,
M. Martinez,
S. Masi,
C. Tomei,
M. Vignati
Abstract:
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $α$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $β/γ$ events. Currently used light detectors have not the…
▽ More
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks to the reduction of the $α$-background, obtained by detecting the Cherenkov light (100 eV) emitted by $β/γ$ events. Currently used light detectors have not the features required to address this task, so we decided to develop a new light detector using Kinetic Inductance Detector as a sensor. This approach is very challenging and requires an intensive R$\&$D to be satisfied. The first results of this activity are shown in the following.
△ Less
Submitted 30 December, 2015;
originally announced December 2015.
-
Characterization of the KID-Based Light Detectors of CALDER
Authors:
N. Casali,
F. Bellini,
L. Cardani,
M. G. Castellano,
I. Colantoni,
A. Coppolecchia,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing phonon-mediated kinetic inductance detectors. The detectors are developed to improve the background suppression in large-mass bolometric experiments such as CUORE, v…
▽ More
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing phonon-mediated kinetic inductance detectors. The detectors are developed to improve the background suppression in large-mass bolometric experiments such as CUORE, via the double read-out of the light and the heat released by particles interacting in the bolometers. In this work, we present the characterization of the first light detectors developed by CALDER. We describe the analysis tools to evaluate the resonator parameters (resonant frequency and quality factors) taking into account simultaneously all the resonance distortions introduced by the read-out chain (as the feed-line impedance and its mismatch) and by the power stored in the resonator itself. We detail the method for the selection of the optimal point for the detector operation (maximizing the signal-to-noise ratio). Finally, we present the response of the detector to optical pulses in the energy range of 0-30 keV.
△ Less
Submitted 17 November, 2015; v1 submitted 16 November, 2015;
originally announced November 2015.
-
Energy resolution and efficiency of phonon-mediated Kinetic Inductance Detectors for light detection
Authors:
L. Cardani,
I. Colantoni,
A. Cruciani,
S. Di Domizio,
M. Vignati,
F. Bellini,
N. Casali,
M. G. Castellano,
A. Coppolecchia,
C. Cosmelli,
C. Tomei
Abstract:
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and the natural multiplexed read-out, Kinetic Inductance Detectors (KIDs) are particularly suitable for this purpose. To efficiently couple KIDs-based light detecto…
▽ More
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and the natural multiplexed read-out, Kinetic Inductance Detectors (KIDs) are particularly suitable for this purpose. To efficiently couple KIDs-based light detectors to the large crystals used by the most advanced bolometric detectors, active surfaces of several cm$^2$ are needed. For this reason, we are developing phonon-mediated detectors. In this paper we present the results obtained with a prototype consisting of four 40 nm thick aluminum resonators patterned on a 2$\times$2 cm$^2$ silicon chip, and calibrated with optical pulses and X-rays. The detector features a noise resolution $σ_E=154\pm7$ eV and an (18$\pm$2)$\%$ efficiency.
△ Less
Submitted 14 September, 2015; v1 submitted 18 May, 2015;
originally announced May 2015.
-
CALDER - Neutrinoless double-beta decay identification in TeO$_2$ bolometers with kinetic inductance detectors
Authors:
E. S. Battistelli,
F. Bellini,
C. Bucci,
M. Calvo,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
A Coppolecchia,
C. Cosmelli,
A. Cruciani,
P. de Bernardis,
S. Di Domizio,
A. D'Addabbo,
M. Martinez,
S. Masi,
L. Pagnanini,
C. Tomei,
M. Vignati
Abstract:
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that can be improved by removing the background from $α$ radioactivity. This is possible if, i…
▽ More
Next-generation experiments searching for neutrinoless double-beta decay must be sensitive to a Majorana neutrino mass as low as 10 meV. CUORE, an array of 988 TeO$_2$ bolometers being commissioned at Laboratori Nazionali del Gran Sasso in Italy, features an expected sensitivity of 50-130 meV at 90% C.L, that can be improved by removing the background from $α$ radioactivity. This is possible if, in coincidence with the heat release in a bolometer, the Cherenkov light emitted by the $β$ signal is detected. The amount of light detected is so far limited to only 100 eV, requiring low-noise cryogenic light detectors. The CALDER project (Cryogenic wide-Area Light Detectors with Excellent Resolution) aims at developing a small prototype experiment consisting of TeO$_2$ bolometers coupled to new light detectors based on kinetic inductance detectors. The R&D is focused on the light detectors that could be implemented in a next-generation neutrinoless double-beta decay experiment.
△ Less
Submitted 19 May, 2015; v1 submitted 6 May, 2015;
originally announced May 2015.