Wakefields In Superconducting RF Cavities and The Impact on VUV Free-electron Laser Oscillator Performance
Authors:
Alex H. Lumpkin,
Henry P. Freund,
Matthias Reinsch,
Peter J. M. van der Slot
Abstract:
The Fermilab Accelerator Science and Technology (FAST) facility is currently in operation with its linac based on TESLA-type superconducting rf cavities. Using a 3-MHz micropulse repetition rate with a long macropulse composed of up to 3000 micropulses, and with beam energies demonstrated at 300 MeV and projected to reach 800 MeV with two additional cryomodules, the feasibilities for a vacuum ultr…
▽ More
The Fermilab Accelerator Science and Technology (FAST) facility is currently in operation with its linac based on TESLA-type superconducting rf cavities. Using a 3-MHz micropulse repetition rate with a long macropulse composed of up to 3000 micropulses, and with beam energies demonstrated at 300 MeV and projected to reach 800 MeV with two additional cryomodules, the feasibilities for a vacuum ultraviolet (VUV) and an extreme ultraviolet (EUV) free-electron laser oscillator (FELO) with the two energies are evaluated. We have used both the GINGER code with an oscillator module and the MINERVA/OPC code to assess FELO saturation prospects at 120 nm with a 5.0-cm-period undulator of 4.5-m length and the MINERVA/OPC code to assess the FELO at 13.4 nm with adjusted parameters. The simulation results support saturation at both of these wavelengths which are much shorter than the demonstrated shortest wavelength record of 168.6 nm from a storage-ring-based FELO. This indicates superconducting rf linac-driven FELOs can be extended into this VUV-EUV wavelength regime previously only reached with single-pass FEL configurations. In addition, emittance-dilution effects due to wakefields in the cavities and the resulting sub-macropulse centroid slew effects on FELO performance are addressed using MINERVA/OPC simulations for the first time.
△ Less
Submitted 20 October, 2023;
originally announced October 2023.
-
Considerations on wakefield effects in a VUV FELO driven by a superconducting tesla-type linac
Authors:
Alex H. Lumpkin,
Henry P. Freund,
Peter Van der Slot
Abstract:
The effects on beam dynamics from long-range and short-range wakefields from TESLA-type cavities are considered in regard to a proposed FEL oscillator (FE-LO) operating at 120 nm. This would be driven by the Fermilab Accelerator Science and Technology (FAST) linac at 300 MeV with a 3-MHz micropulse repetition rate. Our wakefield studies showed measurable effects on submacropulse centroid stability…
▽ More
The effects on beam dynamics from long-range and short-range wakefields from TESLA-type cavities are considered in regard to a proposed FEL oscillator (FE-LO) operating at 120 nm. This would be driven by the Fermilab Accelerator Science and Technology (FAST) linac at 300 MeV with a 3-MHz micropulse repetition rate. Our wakefield studies showed measurable effects on submacropulse centroid stability and on submicropulse head-tail kicks that can lead to emittance degradation. In the case of the former, we use MINERVA/OPC to simulate the ~100-$μ$m centroid slew effects on the saturated output power levels of the FELO.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
Submacropulse electron-beam dynamics correlated with higher-order modes in a Tesla-type cryomodule
Authors:
A. H. Lumpkin,
R. Thurman-Keup,
D. Edstrom,
P. Prieto,
J. Ruan,
B. Jacobson,
J. Sikora,
J. Diaz-Cruz,
A. Edelen,
F. Zhou
Abstract:
Experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of long-range wakefields (LRWs) in TESLA-type superconducting rf cavities. In particular, we investigated the higher-order modes (HOMs) generated in the eight cavities of a cryomodule (CM) due to off-axis steering with correctors located ~4 m upstream of the CM. We have observed c…
▽ More
Experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of long-range wakefields (LRWs) in TESLA-type superconducting rf cavities. In particular, we investigated the higher-order modes (HOMs) generated in the eight cavities of a cryomodule (CM) due to off-axis steering with correctors located ~4 m upstream of the CM. We have observed correlated submacropulse centroid slews of a few-hundred microns and centroid oscillations at ~240 kHz in the rf BPM data after the CM. The entrance energy into the CM was 25 MeV, and the exit energy was 100 MeV with 125 pC/b and 400 pC/b in 50-bunch pulse trains. These experimental results were evaluated for machine learning training aspects which will be used to inform the commissioning plan for the Linac Coherent Light Source-II injector CM.
△ Less
Submitted 1 December, 2021;
originally announced December 2021.
-
Tapered helical undulator system for high efficiency energy extraction from a high brightness electron beam
Authors:
Y. Park,
R. Agustsson,
W. J. Berg,
J. Byrd,
T. J. Campese,
D. Dang,
P. Denham,
J. Dooling,
A. Fisher,
I. Gadjev,
C. Hall,
J. Isen,
J. Jin,
A. H. Lumpkin,
A. Murokh,
Y. Sun,
W. H. Tan,
S. Webb,
K. P. Wootton,
A. A. Zholents,
P. Musumeci
Abstract:
In this paper we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separa…
▽ More
In this paper we discuss the design choices and construction strategy of the tapered undulator system designed for a high energy extraction efficiency experiment in the ultraviolet region of the electromagnetic spectrum planned for installation at the Argonne National Laboratory Linac Extension Area (LEA) beamline. The undulator is comprised of 4 sections pure permanent magnet Halbach array separated by short break sections, each one of them housing a focusing quadrupole doublet and a phase shifter. The quadrupoles use a novel hybrid design which allows one to vary the gradient and match the beam transversely. The undulator tapering profile is optimized to maximize the energy conversion efficiency from a 343 MeV 1 kA beam into coherent 257.5 nm radiation taking into account the longitudinal current profile generated by the linac.
△ Less
Submitted 30 November, 2021; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Interferometric optical signature of electron microbunching in laser-driven plasma accelerators
Authors:
A. H. Lumpkin,
M. LaBerge,
D. W. Rule,
R. Zgadzaj,
A. Hannasch,
O. Zarini,
B. Bowers,
A. Irman,
J. P. Couperus-Cabadag,
A. Debus,
A. Köhler,
U. Schramm,
M. C. Downer
Abstract:
We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ~200-MeV electrons as they emerge from a laser-plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to an analytical COTRI model, is ~6x smaller than the ~3 mrad ensemble beam divergence, while the radius of the microbunched beam, o…
▽ More
We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ~200-MeV electrons as they emerge from a laser-plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to an analytical COTRI model, is ~6x smaller than the ~3 mrad ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is < 3 microns. The combined results show that the microbunched distribution has estimated transverse normalized emittance ~0.5 mm mrad.
△ Less
Submitted 11 July, 2019;
originally announced July 2019.
-
Submacropulse Electron-Beam Dynamics Correlated With Higher-Order Modes In Tesla-Type Superconducting RF Cavities
Authors:
A. H. Lumpkin,
R. Thurman-Keup,
D. Edstrom,
J. Ruan,
N. Eddy,
P. Prieto,
O. Napoly,
B. E. Carlsten,
K. Bishofberger
Abstract:
We report the direct observations of sub-macropulse beam centroid oscillations correlated with higher order modes (HOMs) which were generated by off-axis electron beam steering in TESLA-type superconducting RF cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a photocathode rf gun injecting beam into two se…
▽ More
We report the direct observations of sub-macropulse beam centroid oscillations correlated with higher order modes (HOMs) which were generated by off-axis electron beam steering in TESLA-type superconducting RF cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a photocathode rf gun injecting beam into two separated 9-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. Oscillations of ~100 kHz in the vertical plane and ~380 kHz in the horizontal plane with up to 600-μm amplitudes were observed in a 3-MHz micropulse repetition rate beam with charges of 100, 300, 500, and 1000 pC/b. However, the effects were much reduced at 100 pC/b. The measurements were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch array data, imaging cameras, and a framing camera. Calculations reproduced the oscillation frequencies of the phenomena in the vertical case. In principle, these fundamental results may be scaled to cryomodule configurations of major accelerator facilities.
△ Less
Submitted 11 July, 2018;
originally announced July 2018.
-
First Point-Spread Function and X-Ray Phase-Contrast Imaging Results With an 88-mm Diameter Single Crystal
Authors:
A. H. Lumpkin,
A. B. Garson,
M. A. Anastasio
Abstract:
In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystal…
▽ More
In this study, we report initial demonstrations of the use of single crystals in indirect x-ray imaging with a benchtop implementation of propagation-based (PB) x-ray phase contrast imaging. Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point-spread function (PSF) with the 50-μm thick single crystal scintillators than with the reference polycrystalline phosphor/scintillator. Fiber-optic plate depth-of-focus and Al reflective-coating aspects are also elucidated. Guided by the results from the 25-mm diameter crystal samples, we report additionally the first results with a unique 88-mm diameter single crystal bonded to a fiber optic plate and coupled to the large format CCD. Both PSF and x-ray phase contrast imaging data are quantified and presented.
△ Less
Submitted 5 July, 2018;
originally announced July 2018.
-
From Relativistic Electrons To X-Ray Phase Contrast Imaging
Authors:
A. H. Lumpkin,
A. B. Garson,
M. A. Anastasio
Abstract:
We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the referen…
▽ More
We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 μm (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphor's 80-μm value. Potential fiber-optic plate depth-of-focus aspects and 33-μm diameter carbon fiber imaging are also addressed.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.
-
Feasibility of OTR Imaging For Laser-Driven Plasma Accelerator Electron-Beam Diagnostics
Authors:
A. H. Lumpkin,
D. W. Rule,
M. C. Downer
Abstract:
We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/γ and beam sizes to be determined…
▽ More
We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/γ and beam sizes to be determined at the micron level. Analytical modeling results indicate the feasibility of using these OTR techniques for the LPA applications.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.
-
An optical and terahertz instrumentation system at the FAST linac at Fermilab
Authors:
R. Thurman-Keup,
A. H. Lumpkin,
J. Thangaraj
Abstract:
FAST is a facility at Fermilab that consists of a photoinjector, two superconducting capture cavities, one superconducting ILC-style cryomodule, and a small ring for studying non-linear, integrable beam optics called IOTA. This paper discusses the layout for the optical transport system that provides optical radiation to an externally located streak camera for bunch length measurements, and THz ra…
▽ More
FAST is a facility at Fermilab that consists of a photoinjector, two superconducting capture cavities, one superconducting ILC-style cryomodule, and a small ring for studying non-linear, integrable beam optics called IOTA. This paper discusses the layout for the optical transport system that provides optical radiation to an externally located streak camera for bunch length measurements, and THz radiation to a Martin-Puplett interferometer, also for bunch length measurements. It accepts radiation from two synchrotron radiation ports in a chicane bunch compressor and a diffraction/transition radiation screen downstream of the compressor. It also has the potential to access signal from a transition radiation screen or YAG screen after the spectrometer magnet for measurements of energy-time correlations. Initial results from both the streak camera and Martin-Puplett will be presented.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Diagnostics upgrades for investigations of HOM effects in Tesla-type SCRF cavities
Authors:
A. H. Lumpkin,
D. Edstrom Jr.,
J. Ruan,
R. Thurman-Keup,
Y. Shin,
P. Prieto,
N. Eddy,
B. E. Carlsten
Abstract:
We describe the upgrades to diagnostic capabilities on the Fermilab Accelerator Science and Technology (FAST) electron linear accelerator that will allow investigations of the effects of high-order modes (HOMs) in SCRF cavities on macropulse-average beam quality. We examine the dipole modes in the first pass-band generally observed in the 1.6-1.9 GHz regime for TESLA-type SCRF cavities due to unif…
▽ More
We describe the upgrades to diagnostic capabilities on the Fermilab Accelerator Science and Technology (FAST) electron linear accelerator that will allow investigations of the effects of high-order modes (HOMs) in SCRF cavities on macropulse-average beam quality. We examine the dipole modes in the first pass-band generally observed in the 1.6-1.9 GHz regime for TESLA-type SCRF cavities due to uniform transverse beam offsets of the electron beam. Such cavities are the basis of the accelerators such as the European XFEL and the proposed MaRIE XFEL facility. Preliminary HOM detector data, prototype BPM test data, and first framing camera OTR data with ~20 micron spatial resolution at 250 pC per bunch will be presented.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Initial observations of micropulse elongation of electron beams in a SCRF accelerator
Authors:
A. H. Lumpkin,
R. Thurman-Keup,
D. Edstrom Jr.,
J. Ruan,
J. Santucci
Abstract:
Commissioning at the SCRF accelerator at the Fermilab Accelerator Science and Technology (FAST) Facility has included the implementation of a versatile bunch-length monitor located after the 4-dipole chicane bunch compressor for electron beam energies of 20-50 MeV and integrated charges in excess of 10 nC. The team has initially used a Hamamatsu C5680 synchroscan streak camera to assess the effect…
▽ More
Commissioning at the SCRF accelerator at the Fermilab Accelerator Science and Technology (FAST) Facility has included the implementation of a versatile bunch-length monitor located after the 4-dipole chicane bunch compressor for electron beam energies of 20-50 MeV and integrated charges in excess of 10 nC. The team has initially used a Hamamatsu C5680 synchroscan streak camera to assess the effects of space charge on the electron beam bunch lengths. An Al-coated Si screen was used to generate optical transition radiation (OTR) resulting from the beam's interaction with the screen. The chicane bypass beamline allowed the measurements of the bunch length without the compression stage at the downstream beamline location using OTR and the streak camera. We have observed electron beam bunch lengths from 5 to 16 ps (sigma) for micropulse charges of 60 pC to 800 pC, respectively. We also report a compressed sub-ps micropulse case.
△ Less
Submitted 27 December, 2017;
originally announced December 2017.
-
Initial Demonstration Of 9-MHz Framing Camera Rates On The FAST Drive Laser Pulse Trains
Authors:
A. H. Lumpkin,
D. Edstrom Jr.,
J. Ruan
Abstract:
We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D…
▽ More
We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.
△ Less
Submitted 30 November, 2017;
originally announced December 2017.
-
First Indirect X-Ray Imaging Tests With An 88-mm Diameter Single Crystal
Authors:
A. H. Lumpkin,
A. T. Macrander
Abstract:
Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x-ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100-micron thickness. The crystal was bonded to a fiber optic plate (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution w…
▽ More
Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x-ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100-micron thickness. The crystal was bonded to a fiber optic plate (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self-supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream, adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB-based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. This single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.
△ Less
Submitted 14 September, 2017;
originally announced September 2017.
-
TeV/m Nano-Accelerator: Current Status of CNT-Channeling Acceleration Experiment
Authors:
Y. M. Shin,
A. H. Lumpkin,
J. C. Thangaraj,
R. M. Thurman-Keup,
V. Shiltsev
Abstract:
Crystal channeling technology has offered various opportunities in the accelerator community with a viability of ultrahigh gradient (TV/m) acceleration for future HEP collider. The major challenge of channeling acceleration is that ultimate acceleration gradients might require a high power driver in the hard x-ray regime (~ 40 keV). This x-ray energy exceeds those for x-rays as of today, although…
▽ More
Crystal channeling technology has offered various opportunities in the accelerator community with a viability of ultrahigh gradient (TV/m) acceleration for future HEP collider. The major challenge of channeling acceleration is that ultimate acceleration gradients might require a high power driver in the hard x-ray regime (~ 40 keV). This x-ray energy exceeds those for x-rays as of today, although x-ray lasers can efficiently excite solid plasma and accelerate particles inside a crystal channel. Moreover, only disposable crystal accelerators are possible at such high externally excited fields which would exceed the ionization thresholds destroying the atomic structure, so acceleration will take place only in a short time before full dissociation of the lattice. Carbon-based nanostructures have great potential with a wide range of flexibility and superior physical strength, which can be applied to channeling acceleration. This paper presents a beam-driven channeling acceleration concept with CNTs and discusses feasible experiments with the Advanced Superconducting Test Accelerator (ASTA) in Fermilab.
△ Less
Submitted 4 May, 2017;
originally announced May 2017.
-
Ultra-High Gradient Channeling Acceleration in Nanostructures: Design/Progress of Proof-of-Concept (POC) Experiments
Authors:
Y. M. Shin,
A. Green,
A. H. Lumpkin,
R. M. Thurman-Keup,
V. Shiltsev,
X. Zhang,
D. M. -A. Farinella,
P. Taborek,
T. Tajima,
J. A. Wheeler,
G. Mourou
Abstract:
This paper describes simulation analyses on beam and laser (X-ray)-driven accelerations in effective nanotube models obtained from Vsim and EPOCH codes. Experimental setups to detect wakefields are also outlined with accelerator facilities at Fermilab and NIU. In the FAST facility, the electron beamline was successfully commissioned at 50 MeV and it is being upgraded toward higher energies for ele…
▽ More
This paper describes simulation analyses on beam and laser (X-ray)-driven accelerations in effective nanotube models obtained from Vsim and EPOCH codes. Experimental setups to detect wakefields are also outlined with accelerator facilities at Fermilab and NIU. In the FAST facility, the electron beamline was successfully commissioned at 50 MeV and it is being upgraded toward higher energies for electron accelerator R&D. The 50 MeV injector beamline of the facility is used for X-ray crystal-channeling radiation with a diamond target. It has been proposed to utilize the same diamond crystal for a channeling acceleration POC test. Another POC experiment is also designed for the NIU accelerator lab with time-resolved electron diffraction. Recently, a stable generation of single-cycle laser pulses with tens of Petawatt power based on thin film compression (TFC) technique has been investigated for target normal sheath acceleration (TNSA) and radiation pressure acceleration (RPA). The experimental plan with a nanometer foil is discussed with an available test facility such as Extreme Light Infrastructure - Nuclear Physics (ELI-NP).
△ Less
Submitted 27 December, 2016;
originally announced December 2016.
-
TeV/m Nano-Accelerator: Investigation on Feasibility of CNT-Channeling Acceleration at Fermilab
Authors:
Y. M. Shin,
A. H. Lumpkin,
R. M. Thurman-Keup
Abstract:
The development of high gradient acceleration and tight phase-space control of high power beams is a key element for future lepton and hadron colliders since the increasing demands for higher energy and luminosity significantly raise costs of modern HEP facilities. Atomic channels in crystals are known to consist of 10 -- 100 V/Å potential barriers capable of guiding and collimating a high energy…
▽ More
The development of high gradient acceleration and tight phase-space control of high power beams is a key element for future lepton and hadron colliders since the increasing demands for higher energy and luminosity significantly raise costs of modern HEP facilities. Atomic channels in crystals are known to consist of 10 -- 100 V/Å potential barriers capable of guiding and collimating a high energy beam providing continuously focused acceleration with exceptionally high gradients (TeV/m). However, channels in natural crystals are only angstrom-size and physically vulnerable to high energy interactions, which has prevented crystals from being applied to high power accelerators. Carbon-based nano-crystals such as carbon-nanotubes (CNTs) and graphenes have a large degree of dimensional flexibility and thermo-mechanical strength, which could be suitable for channeling acceleration of MW beams. Nano-channels of the synthetic crystals can accept a few orders of magnitude larger phase-space volume of channeled particles with much higher thermal tolerance than natural crystals. This paper presents the current status of CNT-channeling acceleration research at the Advanced Superconducting Test Accelerator (ASTA) in Fermilab.
△ Less
Submitted 1 April, 2015;
originally announced April 2015.
-
Mitigation Plans for the Microbunching-Instability-Related COTR at ASTA/FNAL
Authors:
A. H. Lumpkin,
M. Church,
A. S. Johnson
Abstract:
At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence…
▽ More
At the Advanced Superconducting Test Accelerator (ASTA) now under construction at Fermilab, we anticipate the appearance of the microbunching instability related to the longitudinal space charge (LSC) impedances. With a photoinjector source and up to two chicane compressors planned, the conditions should result in the shift of some microbunched features into the visible light regime. The presence of longitudinal microstructures (microbunching) in the electron beam or the leading edge spikes can result in strong, spatially localized coherent enhancements of optical transition radiation (COTR) that mask the actual beam profile. Several efforts on mitigation of the effects in the diagnostics task have been identified. At ASTA we have designed the beam profiling stations to have mitigation features based on spectral filtering, scintillator choice, and the timing of the trigger to the digital camera's CCD chip. Since the COTR is more intense in the NIR than UV we have selectable bandpass filters centered at 420 nm which also overlap the spectral emissions of the LYSO:Ce scintillators. By delaying the CCD trigger timing of the integration window by 40-50 ns, we can reject the prompt OTR signal and integrate on the delayed scintillator light predominately. This combination of options should allow mitigation of COTR enhancements of order 100-1000 in the distribution.
△ Less
Submitted 9 September, 2014;
originally announced September 2014.
-
Overview and Issues of Experimental Observation of Microbunching Instabilities
Authors:
Alex H. Lumpkin
Abstract:
The generation of the ultra-bright beams required by modern accelerators and drivers of free-electron lasers (FELs) has generally relied on chicane-based bunch compressions that often result in the microbunching instability. Following compression, spectral enhancements extend even into the visible wavelengths through the longitudinal space charge (LSC) impedances. Optical transition radiation (OTR…
▽ More
The generation of the ultra-bright beams required by modern accelerators and drivers of free-electron lasers (FELs) has generally relied on chicane-based bunch compressions that often result in the microbunching instability. Following compression, spectral enhancements extend even into the visible wavelengths through the longitudinal space charge (LSC) impedances. Optical transition radiation (OTR) screens have been extensively used for transverse electron beam size measurements for the bright beams, but the presence of such longitudinal microstructures (microbunching) in the electron beam or the leading edge spikes can result in strong, localized coherent enhancements (COTR) that mask the actual beam profile. Generally, we have observed effects in rf photocathode (PC) injected linacs with chicane compressions since an R56 term is needed. In the past COTR had been only reported in S-band and L-band photoinjected based linacs with single or double bunch compression. Drive laser modulations and charge shot noise have been suspected of contributing to the cause. We now have evidence for the effects in both rf PC-gun injected linacs and thermionic- cathode (TC)-gun injected linacs (the latter do not involve a drive laser). Since the first observations, significant efforts have been made to characterize, model, and mitigate COTR effects on beam diagnostics. An update on the state-of-the-art for diagnosing these effects will be given as illustrated by examples at the Linac Coherent Light Source (LCLS), Spring-8 Compact SASE Source (SCSS), Spring-8 Angstrom Compact Free Electron LAser (SACLA), Advanced Photon Source (APS), and the Next Linear Collider Test Accelerator (NLCTA). These observations continue to be of interest to the accelerator community.
△ Less
Submitted 5 September, 2014;
originally announced September 2014.
-
Feasibility of Diagnostics Undulator Studies at ASTA
Authors:
A. H. Lumpkin,
M. Wendt,
J. M. Byrd
Abstract:
The Advanced Superconducting Test Accelerator (ASTA) facility is currently under construction at Fermilab. With a 1-ms macropulse composed of up to 3000 micropulses and with beam energies projected from 45 to 800 MeV, the need for non-intercepting diagnostics for beam size, position, energy, and bunch length is clear. In addition to the rf BPMs, optical synchrotron radiation (OSR), and optical dif…
▽ More
The Advanced Superconducting Test Accelerator (ASTA) facility is currently under construction at Fermilab. With a 1-ms macropulse composed of up to 3000 micropulses and with beam energies projected from 45 to 800 MeV, the need for non-intercepting diagnostics for beam size, position, energy, and bunch length is clear. In addition to the rf BPMs, optical synchrotron radiation (OSR), and optical diffraction radiation (ODR) techniques already planned, we propose the use of undulator radiation from a dedicated device for diagnostics. with a nominal period of 4-5 cm, a tunable field parameter K, and a length of several meters. The feasibility of extending such techniques in the visible regime at a beam energy of 125 MeV into the UV and VUV regimes with beam energies of 250 and 500 MeV will be presented.
△ Less
Submitted 29 August, 2014;
originally announced August 2014.
-
Potential For Laser-Induced Microbunching Studies with the 3-MHZ-Rate Electron Beams at ASTA
Authors:
A. H. Lumpkin,
J. Ruan,
J. M. Byrd,
R. B. Wilcox
Abstract:
Investigations of the laser-induced microbunching as it is related to time-sliced electron-beam diagnostics and high-gain-harmonic generation (HGHG) free-electron lasers using bright electron beams are proposed for the ASTA facility. Initial tests at 40-50 MeV with an amplified 800-nm seed laser beam co-propagating with the electron beam through a short undulator (or modulator) tuned for the reson…
▽ More
Investigations of the laser-induced microbunching as it is related to time-sliced electron-beam diagnostics and high-gain-harmonic generation (HGHG) free-electron lasers using bright electron beams are proposed for the ASTA facility. Initial tests at 40-50 MeV with an amplified 800-nm seed laser beam co-propagating with the electron beam through a short undulator (or modulator) tuned for the resonance condition followed by transport through a subsequent chicane will result in energy modulation and z-density modulation (microbunching), respectively. The latter microbunching will result in generation of coherent optical or UV transition radiation (COTR, CUVTR) at a metal converter screen which can reveal slice beam size, centroid, and energy spread. Additionally, direct assessment of the microbunching factors related to HGHG by measurement of the COTR intensity and harmonic content after the chicane as a function of seed laser power and beam parameters will be done. These experiments will be performed using the ASTA 3-MHz-rate micropulse train for up to 1ms which is unique to test facilities in the USA.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
Synchroscan streak camera imaging at a 15-MeV photoinjector with emittance exchange
Authors:
A. H. Lumpkin,
J. Ruan,
R. Thurman-Keup
Abstract:
At the Fermilab A0 photoinjector facility, bunch-length measurements of the laser micropulse and the e-beam micropulse have been done in the past with a fast single-sweep module of the Hamamatsu C5680 streak camera with an intrinsic shot-to-shot trigger jitter of 10-20ps. We have upgraded the camera system with the synchroscan module tuned to 81.25MHz to provide synchronous summing capability with…
▽ More
At the Fermilab A0 photoinjector facility, bunch-length measurements of the laser micropulse and the e-beam micropulse have been done in the past with a fast single-sweep module of the Hamamatsu C5680 streak camera with an intrinsic shot-to-shot trigger jitter of 10-20ps. We have upgraded the camera system with the synchroscan module tuned to 81.25MHz to provide synchronous summing capability with less than 1.5ps FWHM trigger jitter and a phase-locked delay box to provide phase stability of ~1ps over 10s of minutes. These steps allowed us to measure both the UV laser pulse train at 263nm and the e-beam via optical transition radiation (OTR). Due to the low electron beam energies and OTR signals, we typically summed over 50 micropulses with 0.25-1nC per micropulse. The phase-locked delay box allowed us to assess chromatic temporal effects and instigated another upgrade to an all-mirror input optics barrel. In addition, we added a slow sweep horizontal deflection plug-in unit to provide dual-sweep capability for the streak camera. We report on a series of measurements made during the commissioning of these upgrades including bunch-length and phase effects using the emittance exchange beamline and simultaneous imaging of a UV drive laser component, OTR, and the 800nm diagnostics laser.
△ Less
Submitted 3 October, 2012;
originally announced October 2012.
-
Feasibility of OTR imaging of non-relativistic ions at GSI
Authors:
A. H. Lumpkin
Abstract:
The feasibility of using the optical transition radiation (OTR) generated as a 11.4- to 300-MeV/μion beam passes through a single metal conducting plane for a minimally intercepting beam profile monitor for GSI/Darmstadt has been evaluated for the first time. Although these are non-relativistic beams, their beta and gamma values are similar to the 80-keV electron-beam imaging studies previously do…
▽ More
The feasibility of using the optical transition radiation (OTR) generated as a 11.4- to 300-MeV/μion beam passes through a single metal conducting plane for a minimally intercepting beam profile monitor for GSI/Darmstadt has been evaluated for the first time. Although these are non-relativistic beams, their beta and gamma values are similar to the 80-keV electron-beam imaging studies previously done on the CTF3 injector. With anticipated beam intensities of 109 to 1011 particles per pulse and the predicted charge-squared dependence of OTR, the ion charge state becomes a critical factor for photon production. The OTR signal from the ion charge integrated over the video field time should be comparable to or larger than the CTF3 electron case. These signal strengths will allow a series of experiments to be done that should further elucidate the working regime of this technique.
△ Less
Submitted 21 August, 2012;
originally announced August 2012.
-
The feasibility of near-field ODR beam-size monitoring at 23 GeV at FACET
Authors:
A. H. Lumpkin,
C. -Y. Yao,
M. Hogan,
P. Muggli
Abstract:
Extension of near-field optical diffraction radiation (ODR) imaging to the 23 GeV beams at the proposed FACET facility at SLAC has been evaluated. The beam-size sensitivity at the 10- to 20- μm sigma level based on a simple model will be reported. Polarization effects are also seen to be important and will be discussed. The comparisons to previous experimental results and the modeling results indi…
▽ More
Extension of near-field optical diffraction radiation (ODR) imaging to the 23 GeV beams at the proposed FACET facility at SLAC has been evaluated. The beam-size sensitivity at the 10- to 20- μm sigma level based on a simple model will be reported. Polarization effects are also seen to be important and will be discussed. The comparisons to previous experimental results and the modeling results indicate sufficient feasibility for planning of the experiments in the coming year.
△ Less
Submitted 21 August, 2012;
originally announced August 2012.
-
Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector
Authors:
A. H. Lumpkin,
A. S. Johnson,
J. Ruan,
J. Santucci,
Y. -E. Sun,
R. Thurman-Keup,
H. Edwards
Abstract:
The possibility of using electron beam phase space manipulations to support a free-electron laser accelerator design optimization has motivated our research. An on-going program demonstrating the exchange of transverse horizontal and longitudinal emittances at the Fermilab A0 photoinjector has benefited recently from the upgrade of several of the key diagnostics stations. Accurate measurements of…
▽ More
The possibility of using electron beam phase space manipulations to support a free-electron laser accelerator design optimization has motivated our research. An on-going program demonstrating the exchange of transverse horizontal and longitudinal emittances at the Fermilab A0 photoinjector has benefited recently from the upgrade of several of the key diagnostics stations. Accurate measurements of these properties upstream and downstream of the exchanger beamline are needed. Improvements in the screen resolution term and reduced impact of the optical system's depth-of-focus by using YAG:Ce single crystals normal to the beam direction will be described. The requirement to measure small energy spreads (<10 keV) in the spectrometer and the exchange process which resulted in bunch lengths less than 500 fs led to other diagnostics performance adjustments and upgrades as well. A longitudinal to transverse exchange example is also reported.
△ Less
Submitted 9 August, 2012;
originally announced August 2012.
-
Overview of non-intercepting beam-size monitoring with optical diffraction radiation
Authors:
Alex H. Lumpkin
Abstract:
The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as non-intercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to be…
▽ More
The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as non-intercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.
△ Less
Submitted 19 July, 2012;
originally announced July 2012.
-
Imaging Techniques for Relativistic Beams: Issues and Limitations
Authors:
Alex H. Lumpkin,
Manfred Wendt
Abstract:
Characterizations of transverse profiles for low-power beams in the accelerators of the proposed linear colliders (ILC and CLIC) using imaging techniques are being evaluated. Assessments of the issues and limitations for imaging relativistic beams with intercepting scintillator or optical transition radiation screens are presented based on low-energy tests at the Fermilab A0 photoinjector and are…
▽ More
Characterizations of transverse profiles for low-power beams in the accelerators of the proposed linear colliders (ILC and CLIC) using imaging techniques are being evaluated. Assessments of the issues and limitations for imaging relativistic beams with intercepting scintillator or optical transition radiation screens are presented based on low-energy tests at the Fermilab A0 photoinjector and are planned for the Advanced Superconducting Test Accelerator at Fermilab.
△ Less
Submitted 29 February, 2012;
originally announced February 2012.
-
Experimental study of coherent synchrotron radiation in the emittance exchange line at the A0-photoinjector
Authors:
Jayakar C. T. Thangaraj,
R. Thurman-Keup,
A. Johnson,
A. H. Lumpkin,
H. Edwards,
J. Ruan,
J. Santucci,
Y. E. - Sun,
M. Church,
P. Piot
Abstract:
Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could…
▽ More
Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
Observation of Coherently-Enhanced Tunable Narrow-Band Terahertz Transition Radiation from a Relativistic Sub-Picosecond Electron Bunch Train
Authors:
P. Piot,
Y. -E Sun,
T. J. Maxwell,
J. Ruan,
A. H. Lumpkin,
M. M. Rihaoui,
R. Thurman-Keup
Abstract:
We experimentally demonstrate the production of narrow-band ($δf/f \simeq20$% at $f\simeq 0.5$ THz) THz transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. We also show a possible application of modulated beams to extend the…
▽ More
We experimentally demonstrate the production of narrow-band ($δf/f \simeq20$% at $f\simeq 0.5$ THz) THz transition radiation with tunable frequency over [0.37, 0.86] THz. The radiation is produced as a train of sub-picosecond relativistic electron bunches transits at the vacuum-aluminum interface of an aluminum converter screen. We also show a possible application of modulated beams to extend the dynamical range of a popular bunch length diagnostic technique based on the spectral analysis of coherent radiation.
△ Less
Submitted 19 April, 2011;
originally announced April 2011.
-
First observation of the exchange of transverse and longitudinal emittances
Authors:
J. Ruan,
A. S. Johnson,
A. H. Lumpkin,
R. Thurman-Keup,
H. Edwards,
R. P. Fliller,
T. Koeth,
Y. -E Sun
Abstract:
An experimental program to demonstrate a novel phase space manipulation in which the horizontal and longitudinal emittances of a particle beam are exchanged has been completed at the Fermilab A0 Photoinjector. A new beamline, consisting of a TM110 deflecting mode cavity flanked by two horizontally dispersive doglegs has been installed. We report on the first direct observation of transverse and lo…
▽ More
An experimental program to demonstrate a novel phase space manipulation in which the horizontal and longitudinal emittances of a particle beam are exchanged has been completed at the Fermilab A0 Photoinjector. A new beamline, consisting of a TM110 deflecting mode cavity flanked by two horizontally dispersive doglegs has been installed. We report on the first direct observation of transverse and longitudinal emittance exchange.
△ Less
Submitted 20 June, 2011; v1 submitted 15 February, 2011;
originally announced February 2011.
-
Tunable subpicosecond electron bunch train generation using a transverse-to-longitudinal phase space exchange technique
Authors:
Y. -E Sun,
P. Piot,
A. Johnson,
A. H. Lumpkin,
T. J. Maxwell,
J. Ruan,
R. Thurman-Keup
Abstract:
We report on the experimental generation of a train of subpicosecond electron bunches. The bunch train generation is accomplished using a beamline capable of exchanging the coordinates between the horizontal and longitudinal degrees of freedom. An initial beam consisting of a set of horizontally-separated beamlets is converted into a train of bunches temporally separated with tunable bunch duratio…
▽ More
We report on the experimental generation of a train of subpicosecond electron bunches. The bunch train generation is accomplished using a beamline capable of exchanging the coordinates between the horizontal and longitudinal degrees of freedom. An initial beam consisting of a set of horizontally-separated beamlets is converted into a train of bunches temporally separated with tunable bunch duration and separation. The experiment reported in this Letter unambiguously demonstrates the conversion process and its versatility.
△ Less
Submitted 4 November, 2010;
originally announced November 2010.