Characterisation and simulation of stitched CMOS strip sensors
Authors:
Naomi Davis,
Jan-Hendrik Arling,
Marta Baselga,
Leena Diehl,
Jochen Dingfelder,
Ingrid-Maria Gregor,
Marc Hauser,
Fabian Hügging,
Tomasz Hemperek,
Karl Jakobs,
Michael Karagounis,
Roland Koppenhöfer,
Kevin Kröninger,
Fabian Lex,
Ulrich Parzefall,
Arturo Rodriguez,
Birkan Sari,
Niels Sorgenfrei,
Simon Spannagel,
Dennis Sperlich,
Tianyang Wang,
Jens Weingarten,
Iveta Zatocilova
Abstract:
In high-energy physics, there is a need to investigate alternative silicon sensor concepts that offer cost-efficient, large-area coverage. Sensors based on CMOS imaging technology present such a silicon sensor concept for tracking detectors. The CMOS Strips project investigates passive CMOS strip sensors fabricated by LFoundry in a 150nm technology. By employing the technique of stitching, two dif…
▽ More
In high-energy physics, there is a need to investigate alternative silicon sensor concepts that offer cost-efficient, large-area coverage. Sensors based on CMOS imaging technology present such a silicon sensor concept for tracking detectors. The CMOS Strips project investigates passive CMOS strip sensors fabricated by LFoundry in a 150nm technology. By employing the technique of stitching, two different strip sensor formats have been realised. The sensor performance is characterised based on measurements at the DESY II Test Beam Facility. The sensor response was simulated utilising Monte Carlo methods and electric fields provided by TCAD device simulations. This study shows that employing the stitching technique does not affect the hit detection efficiency. A first look at the electric field within the sensor and its impact on generated charge carriers is being discussed.
△ Less
Submitted 14 May, 2024;
originally announced May 2024.
-
Characterization, Simulation and Test Beam Data Analysis of Stitched Passive CMOS Strip Sensors
Authors:
I. Zatocilova,
J. -H. Arling,
M. Baselga,
N. Davis,
L. Diehl,
J. Dingfelder,
I. -M. Gregor,
M. Hauser,
T. Hemperek,
F. Hügging,
K. Jakobs,
M. Karagounis,
K. Kröninger,
F. Lex,
U. Parzefall,
A. Rodriguez,
B. Sari,
N. Sorgenfrei,
S. Spannagel,
D. Sperlich,
T. Wang,
J. Weingarten
Abstract:
In the passive CMOS Strips Project, strip sensors were designed at the University of Bonn and produced by LFoundry in 150 nm technology, with an additional backside processing from IZM Berlin. Up to five individual reticules were connected by stitching at the foundry in order to obtain the typical strip lengths required for the LHC Phase-II upgrade of ATLAS or CMS trackers. After dicing, sensors w…
▽ More
In the passive CMOS Strips Project, strip sensors were designed at the University of Bonn and produced by LFoundry in 150 nm technology, with an additional backside processing from IZM Berlin. Up to five individual reticules were connected by stitching at the foundry in order to obtain the typical strip lengths required for the LHC Phase-II upgrade of ATLAS or CMS trackers. After dicing, sensors were tested in a probe station and characterised with a Sr90-source as well as laser-based edge- and top-TCT systems. Sensors were also simulated using Sentaurus TCAD. At last, detector modules were constructed from several sensors and thoroughly studied in two beam campaigns at DESY. All of these measurements were performed before and after irradiation. This contribution provides an overview of simulation results, summarises the laboratory measurements and in particular presents first test beam results for irradiated and unirradiated passive CMOS strip sensors. We are demonstrating that large area sensors with sufficient radiation hardness can be obtained by stitching during the CMOS process, and presenting our plans for the next submission in the framework of this project.
△ Less
Submitted 15 November, 2023; v1 submitted 28 September, 2023;
originally announced September 2023.
-
Accurate and fast deep learning dose prediction for a preclinical microbeam radiation therapy study using low-statistics Monte Carlo simulations
Authors:
Florian Mentzel,
Jason Paino,
Micah Barnes,
Matthew Cameron,
Stéphanie Corde,
Elette Engels,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Anatoly Rosenfeld,
Moeva Tehei,
Ah Chung Tsoi,
Sarah Vogel,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Mo…
▽ More
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription dose estimations for treating preclinical gliosarcoma models in MRT studies at the Imaging and Medical Beamline at the Australian Synchrotron currently rely on Monte Carlo (MC) simulations. The steep dose gradients associated with the 50$\,μ$m wide coplanar beamlets present a significant challenge for precise MC simulation of the MRT irradiation treatment field in a short time frame. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiation treatment options like MRT. In this work, the successful application of a fast and accurate machine learning dose prediction model in a retrospective preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the gliosarcoma in rodent patients. The predictions of the ML model show excellent agreement with low-noise MC simulations, especially within the investigated tumour volume. This agreement is despite the ML model being deliberately trained with MC-calculated samples exhibiting significantly higher statistical uncertainties. The successful use of high-noise training set data samples, which are much faster to generate, encourages and accelerates the transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.
△ Less
Submitted 6 April, 2023; v1 submitted 11 December, 2022;
originally announced December 2022.
-
A step towards treatment planning for microbeam radiation therapy: fast peak and valley dose predictions with 3D U-Nets
Authors:
Florian Mentzel,
Micah Barnes,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro…
▽ More
Fast and accurate dose predictions are one of the bottlenecks in treatment planning for microbeam radiation therapy (MRT). In this paper, we propose a machine learning (ML) model based on a 3D U-Net. Our approach predicts separately the large doses of the narrow high intensity synchrotron microbeams and the lower valley doses between them. For this purpose, a concept of macro peak doses and macro valley doses is introduced, describing the respective doses not on a microscopic level but as macroscopic quantities in larger voxels. The ML model is trained to mimic full Monte Carlo (MC) data. Complex physical effects such as polarization are therefore automatically taking into account by the model.
The macro dose distribution approach described in this study allows for superimposing single microbeam predictions to a beam array field making it an interesting candidate for treatment planning. It is shown that the proposed approach can overcome a main obstacle with microbeam dose predictions by predicting a full microbeam irradiation field in less than a minute while maintaining reasonable accuracy.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Characterization of pixelated silicon detectors for daily quality assurance measurements in proton therapy
Authors:
Isabelle Schilling,
Claus Maximillian Bäcker,
Christian Bäumer,
Carina Behrends,
Kevin Kröninger,
Beate Timmermann,
Jens Weingarten
Abstract:
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly include small radiation fields with large dose gradients, which require detector systems with high spatial resolution for quality assurance. In addition the measureme…
▽ More
The advanced imaging and delivery techniques in proton therapy allow conformal high-dose irradiation of the target volume with high accuracy using pencil beam scanning or beam shaping apertures. These irradiation methods increasingly include small radiation fields with large dose gradients, which require detector systems with high spatial resolution for quality assurance. In addition the measurement of all success parameters for daily quality assurance with only one proton field and one simple detector system would save a lot of time in clinical usage. Based on their good spatial resolution and high rate compatibility, pixelated silicon detectors could meet the new requirements. To assess their applicability in proton therapy, ATLAS pixelated silicon detectors are used to measure the lateral beam profile with high spatial resolution. Furthermore, a dose dependent detector calibration is presented to allow the measurement of the requested output constancy. A strategy to verify the proton energy during the daily quality assurance is under study. Promising results from proof-of-principle measurements at the West German Proton Therapy Centre in Essen, Germany, have been obtained.
△ Less
Submitted 5 April, 2022;
originally announced April 2022.
-
Fast and accurate dose predictions for novel radiotherapy treatments in heterogeneous phantoms using conditional 3D-UNet generative adversarial networks
Authors:
Florian Mentzel,
Kevin Kröninger,
Michael Lerch,
Olaf Nackenhorst,
Jason Paino,
Anatoly Rosenfeld,
Ayu Saraswati,
Ah Chung Tsoi,
Jens Weingarten,
Markus Hagenbuchner,
Susanna Guatelli
Abstract:
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore proh…
▽ More
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose estimations suitable for novel treatments using digital phantoms used in pre-clinical development and modern machine learning techniques. We develop a generative adversarial network (GAN) model, which is able to emulate the equivalent Geant4 Monte Carlo simulation with adequate accuracy, and use it to predict the radiation dose delivered by a broad synchrotron beam to various phantoms. The energy depositions used for the training of the GAN are obtained using full Geant4 Monte Carlo simulations of a synchrotron radiation broad beam passing through the phantoms. The energy deposition is scored and predicted in voxel matrices of size 140x18x18 with a voxel edge length of 1 mm. The GAN model consists of two competing 3D convolutional neural networks, which are conditioned on the photon beam and phantom properties. The energy deposition predictions inside all phantom geometries under investigation show deviations of less than 3% of the maximum deposited energy from the simulation for roughly 99% of the voxels in the field of the beam. The computing time for a single prediction is reduced from several hundred hours using Geant4 simulation to less than a second using the GAN model.
△ Less
Submitted 16 February, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)
Authors:
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart Corominas,
K. Gusev,
B. Hackett,
C. Hayward,
R. Hodák,
P. Krause,
B. Majorovits,
L. Manzanillas,
D. Muenstermann,
M. Pohl,
R. Rouhana,
D. Radford,
E. Rukhadze,
N. Rumyantseva,
I. Schilling,
S. Schoenert,
O. Schulz,
M. Schwarz,
I. Štekl,
M. Stommel,
J. Weingarten,
E. Hoppe
, et al. (6 additional authors not shown)
Abstract:
Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare e…
▽ More
Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of background events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.
△ Less
Submitted 21 November, 2022; v1 submitted 25 October, 2021;
originally announced October 2021.
-
No more glowing in the dark: How deep learning improves exposure date estimation in thermoluminescence dosimetry
Authors:
Florian Mentzel,
Evelin Derugin,
Hannah Jansen,
Kevin Kröninger,
Olaf Nackenhorst,
Jörg Walbersloh,
Jens Weingarten
Abstract:
The time- or temperature-resolved detector signal from a thermoluminescence dosimeter can reveal additional information about circumstances of an exposure to ionizing irradiation. We present studies using deep neural networks to estimate the date of a single irradiation with 12 mSv within a monitoring interval of 42 days from glow curves of novel TL-DOS personal dosimeters developed by the Materia…
▽ More
The time- or temperature-resolved detector signal from a thermoluminescence dosimeter can reveal additional information about circumstances of an exposure to ionizing irradiation. We present studies using deep neural networks to estimate the date of a single irradiation with 12 mSv within a monitoring interval of 42 days from glow curves of novel TL-DOS personal dosimeters developed by the Materialprüfungsamt NRW in cooperation with TU Dortmund University. Using a deep convolutional network, the irradiation date can be predicted from raw time-resolved glow curve data with an uncertainty of roughly 1-2 days on a 68% confidence level without the need for a prior transformation into temperature space and a subsequent glow curve deconvolution. This corresponds to a significant improvement in prediction accuracy compared to a prior publication, which yielded a prediction uncertainty of 2-4 days using features obtained from a glow curve deconvolution as input to a neural network.
△ Less
Submitted 2 September, 2021; v1 submitted 14 June, 2021;
originally announced June 2021.
-
Usage of PEN as self-vetoing structural material in low background experiments
Authors:
I. Abt,
Y. Efremenko,
M. Febbraro,
F. Fischer,
M. Guitart,
K. Gusev,
B. Hackett,
C. Hayward,
R. Hodak,
P. Krause,
B. Majorovits,
L. Manzanillas,
D. Muenstermann,
R. Pjatkan,
M. Pohl,
R. Rouhana,
D. Radford,
E. Rukhadze,
N. Rumyantseva,
I. Schilling,
S. Schoenert,
O. Schulz,
M. Schwarz,
M. Stommel,
J. Weingarten
Abstract:
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background exper…
▽ More
PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background experiments. One possible application are holders for germanium detectors operating in cryogenic liquids (LAr, LN2). Such structures can help to reject surface and external backgrounds, boosting the sensitivity of experiments. In this contribution, the R\&D on PEN is outlined and an evaluation of the first production of PEN structures for the LEGEND-200 experiment is reported.
△ Less
Submitted 9 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes
Authors:
P. Ahlburg,
S. Arfaoui,
J. -H. Arling,
H. Augustin,
D. Barney,
M. Benoit,
T. Bisanz,
E. Corrin,
D. Cussans,
D. Dannheim,
J. Dreyling-Eschweiler,
T. Eichhorn,
A. Fiergolski,
I. -M. Gregor,
J. Grosse-Knetter,
D. Haas,
L. Huth,
A. Irles,
H. Jansen,
J. Janssen,
M. Keil,
J. S. Keller,
M. Kiehn,
H. J. Kim,
J. Kroll
, et al. (32 additional authors not shown)
Abstract:
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed…
▽ More
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
△ Less
Submitted 18 November, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
First Annealing Studies of Irradiated Silicon Sensors with Modified ATLAS Pixel Implantations
Authors:
M. Wagner,
A. Gisen,
M. Hötting,
V. Hohm,
C. Krause,
K. Kröninger,
A. Kroner,
J. Lönker,
M. Muschak,
J. Weingarten,
F. Wizemann
Abstract:
Planar silicon pixel sensors with modified n$^+$-implantation shapes based on the IBL pixel sensor were designed in Dortmund. The sensors with a pixel size of $250\,μ$m $\times$ $50\,μ$m are produced in n$^+$-in-n sensor technology.
The charge collection efficiency should improve with electrical field strength maxima created by the different n$^+$-implantation shapes. Therefore, higher particle…
▽ More
Planar silicon pixel sensors with modified n$^+$-implantation shapes based on the IBL pixel sensor were designed in Dortmund. The sensors with a pixel size of $250\,μ$m $\times$ $50\,μ$m are produced in n$^+$-in-n sensor technology.
The charge collection efficiency should improve with electrical field strength maxima created by the different n$^+$-implantation shapes. Therefore, higher particle detection efficiencies at lower bias voltages could be achieved. The modified pixel designs and the IBL standard design are placed on one sensor to test and compare the designs. The sensor can be read out with the FE-I4 readout chip.
At the iWoRiD 2018, measurements of sensors irradiated with protons and neutrons respectively at different facilities were presented and showed incongruent results. Unintended annealing during irradiation was considered as an explanation for the observed differences in the hit detection efficiency for two neutron irradiated sensors. This hypothesis will be examined and confirmed in this work, presenting first annealing studies of sensors irradiated with neutrons in Ljubljana.
△ Less
Submitted 9 October, 2019; v1 submitted 28 August, 2019;
originally announced August 2019.
-
Temperature scaling of reverse current generated in proton irradiated silicon bulk
Authors:
Felix Wizemann,
Andreas Gisen,
Kevin Kröninger,
Jens Weingarten
Abstract:
The value of the scaling parameter $E_{\text{eff}}$ of the temperature dependence for current generated in silicon bulk is investigated for highly irradiated devices.
Measurements of devices irradiated to fluences above $1 \times 10^{15} n_{\text{eq}} \text{cm}^{-2} $ have shown a different temperature scaling behaviour than devices irradiated to lower fluences. This paper presents the determina…
▽ More
The value of the scaling parameter $E_{\text{eff}}$ of the temperature dependence for current generated in silicon bulk is investigated for highly irradiated devices.
Measurements of devices irradiated to fluences above $1 \times 10^{15} n_{\text{eq}} \text{cm}^{-2} $ have shown a different temperature scaling behaviour than devices irradiated to lower fluences. This paper presents the determination of the parameter $E_{\text{eff}}$ for diodes irradiated with protons up to fluences of $3 \times 10^{15} n_{\text{eq}} \text{cm}^{-2}$ in the bias range from $0$V to $1000$V at temperatures from $-36 ^{\circ}\text{C}$ to $0 ^{\circ}\text{C}$ at different stages of annealing. It is shown that $E_{\text{eff}}$ for highly irradiated devices depends on the applied electric field: below depletion voltage, $E_{\text{eff}}$ is observed to have a lower value than above depletion voltage
△ Less
Submitted 6 June, 2019; v1 submitted 9 April, 2019;
originally announced April 2019.
-
Beam tests of silicon pixel 3D-sensors developed at SINTEF
Authors:
Ole Dorholt,
Thor-Erik Hansen,
Andreas Heggelund,
Angela Kok,
Nicola Pacifico,
Ole Rohne,
Heidi Sandaker,
Bjarne Stugu,
Zongchang Yang,
Marco Bomben,
Andre Rummler,
Jens Weingarten
Abstract:
For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High Luminosity LHC, but also for space physics and medical applications. In this paper, prototype sensors developed at SINTEF are presented and results from tests in…
▽ More
For the purpose of withstanding very high radiation doses, silicon pixel sensors with a 3D electrode geometry are being developed. Detectors of this kind are highly interesting for harch radiation environments such as expected in the High Luminosity LHC, but also for space physics and medical applications. In this paper, prototype sensors developed at SINTEF are presented and results from tests in a pion beam at CERN are given. These tests shows that these 3D sensors perform as expected with full efficiency at bias voltages between 5 and 15V.
△ Less
Submitted 5 August, 2018; v1 submitted 21 June, 2018;
originally announced June 2018.
-
Summary and Conclusions of the 'JRA Beam Telescope 2025'-Forum at the 6th Beam Telescopes and Test Beams Workshop
Authors:
J. Dreyling-Eschweiler,
H. Jansen,
M. S. Amjad,
J. -H. Arling,
T. Coates,
A. Dätwyler,
D. Dannheim,
M. W. U. van Dijk,
T. Eichhorn,
A. Gerbershagen,
O. Girard,
B. Gkotse,
F. J. Iguaz,
J. Kroll,
C. Nellist,
F. Ravotti,
E. Rossi,
A. Rummler,
F. Salvatore,
S. Spannagel,
M. Weers,
J. Weingarten
Abstract:
On January 17th 2018, a forum on a possible Joint Research Activity on a future common Beam Telescope was held during the 6th Beam Telescopes and Test Beams Workshop (BTTB) in Zurich, Switzerland. The BTTB workshop aims at bringing together the community involved in beam tests. It therefore offers a suitable platform to induce community-wide discussions. The forum and its discussions were well rec…
▽ More
On January 17th 2018, a forum on a possible Joint Research Activity on a future common Beam Telescope was held during the 6th Beam Telescopes and Test Beams Workshop (BTTB) in Zurich, Switzerland. The BTTB workshop aims at bringing together the community involved in beam tests. It therefore offers a suitable platform to induce community-wide discussions. The forum and its discussions were well received and the participants concluded that appropriate actions should be undertaken promptly. Specific hardware and software proposals were discussed, with an emphasis on improving current common EUDET-type telescopes based on Mimosa26 sensors towards higher trigger rate capabilities in convolution with considerably improved time resolution. EUDAQ as a common top level DAQ and its modular structure is ready for future hardware. EUTelescope fulfils many requirements of a common reconstruction framework, but has also various drawbacks. Thus, requirements for a new common reconstruction framework were collected. A new common beam telescope evolves with the sensor decision and the whole package including a reconstruction framework depends on that decision.
△ Less
Submitted 8 January, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Performance of active edge pixel sensors
Authors:
Marco Bomben,
Audrey Ducourthial,
Alvise Bagolini,
Maurizio Boscardin,
Luciano Bosisio,
Giovanni Calderini,
Louis D'Eramo,
Gabriele Giacomini,
Giovanni Marchiori,
Nicola Zorzi,
André Rummler,
Jens Weingarten
Abstract:
To cope with the High Luminosity LHC harsh conditions, the ATLAS inner tracker has to be upgraded to meet requirements in terms of radiation hardness, pile up and geometrical acceptance. The active edge technology allows to reduce the insensitive area at the border of the sensor thanks to an ion etched trench which avoids the crystal damage produced by the standard mechanical dicing process. Thin…
▽ More
To cope with the High Luminosity LHC harsh conditions, the ATLAS inner tracker has to be upgraded to meet requirements in terms of radiation hardness, pile up and geometrical acceptance. The active edge technology allows to reduce the insensitive area at the border of the sensor thanks to an ion etched trench which avoids the crystal damage produced by the standard mechanical dicing process. Thin planar n-on-p pixel sensors with active edge have been designed and produced by LPNHE and FBK foundry. Two detector module prototypes, consisting of pixel sensors connected to FE-I4B readout chips, have been tested with beams at CERN and DESY. In this paper the performance of these modules are reported. In particular the lateral extension of the detection volume, beyond the pixel region, is investigated and the results show high hit-efficiency also at the detector edge, even in presence of guard rings.
△ Less
Submitted 4 April, 2017; v1 submitted 6 February, 2017;
originally announced February 2017.
-
Subpixel Mapping and Test Beam Studies with a HV2FEI4v2 CMOS-Sensor-Hybrid Module for the ATLAS Inner Detector Upgrade
Authors:
T. Bisanz,
J. Große-Knetter,
A. Quadt,
J. Rieger,
J. Weingarten
Abstract:
The upgrade to the High Luminosity Large Hadron Collider will pose unprecedented challenges to the tracking systems of all experiments. Recent advancement of active pixel detectors designed in CMOS processes provide attractive alternatives to the well-established hybrid design using passive sensors. This article presents studies with a high-voltage CMOS active pixel sensor designed for the ATLAS t…
▽ More
The upgrade to the High Luminosity Large Hadron Collider will pose unprecedented challenges to the tracking systems of all experiments. Recent advancement of active pixel detectors designed in CMOS processes provide attractive alternatives to the well-established hybrid design using passive sensors. This article presents studies with a high-voltage CMOS active pixel sensor designed for the ATLAS tracker upgrade. The sensor is glued to the read-out chip of the Insertable B-Layer. The device under test is structured in smaller pixels than those of the attached read-out chip with information on the hit CMOS pixel encoded in the output signal (subpixel encoding). Test beam measurements mapping recorded hits in the read-out chip to CMOS pixels, thus validating the subpixel encoding, are described.
△ Less
Submitted 6 February, 2017;
originally announced February 2017.
-
Planar Pixel Sensors for the ATLAS Upgrade: Beam Tests results
Authors:
J. Weingarten,
S. Altenheiner,
M. Beimforde,
M. Benoit,
M. Bomben,
G. Calderini,
C. Gallrapp,
M. George,
S. Gibson,
S. Grinstein,
Z. Janoska,
J. Jentzsch,
O. Jinnouchi,
T. Kishida,
A. La Rosa,
V. Libov,
A. Macchiolo,
G. Marchiori,
D. Münstermann,
R. Nagai,
G. Piacquadio,
B. Ristic,
I. Rubinskiy,
A. Rummler,
Y. Takubo
, et al. (6 additional authors not shown)
Abstract:
Results of beam tests with planar silicon pixel sensors aimed towards the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades are presented. Measurements include spatial resolution, charge collection performance and charge sharing between neighbouring cells as a function of track incidence angle for different bulk materials. Measurements of n-in-n pixel sensors are presented as a fu…
▽ More
Results of beam tests with planar silicon pixel sensors aimed towards the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades are presented. Measurements include spatial resolution, charge collection performance and charge sharing between neighbouring cells as a function of track incidence angle for different bulk materials. Measurements of n-in-n pixel sensors are presented as a function of fluence for different irradiations. Furthermore p-type silicon sensors from several vendors with slightly differing layouts were tested. All tested sensors were connected by bump-bonding to the ATLAS Pixel read-out chip. We show that both n-type and p-type tested planar sensors are able to collect significant charge even after integrated fluences expected at HL-LHC.
△ Less
Submitted 9 November, 2012; v1 submitted 5 April, 2012;
originally announced April 2012.
-
On the Response of an OST to a Point-like Heat Source
Authors:
A. Quadt,
B. Schröder,
M. Uhrmacher,
J. Weingarten,
B. Willenberg,
H. Vennekate
Abstract:
A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillatio…
▽ More
A new technique of superconducting cavity diagnostics has been introduced by D. Hartrill at Cornell University, Ithaca, USA. Oscillating Superleak Transducers (OST) detect the heat transferred from a cavity's quench point via "Second Sound" through the superfluid He bath, needed to cool the superconducting cavity. The observed response of an OST is a complex, but reproducible pattern of oscillations. A small helium evaporation cryostat was built which allows the investigation of the response of an OST in greater detail. The distance between a point-like electrical heater and the OST can be varied. The OST can be mounted either parallel or perpendicular to the plate, housing the heat source. If the artificial quench-point releases an amount of energy compatible to a real quench spot on a cavity's surface, the OST signal starts with a negative pulse, which is usually strong enough to allow automatic detection. Furthermore, the reflection of the Second Sound on the wall is observed. A reflection coefficient R = 0.39 +- 0.05 of the glass wall is measured. This excludes a strong influence of multiple reflections in the complex OST response. Fourier analyses show three main frequencies, found in all OST spectra. They can be interpreted as modes of an oscillating circular membrane.
△ Less
Submitted 23 November, 2011;
originally announced November 2011.
-
A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
Authors:
E. Abat,
J. M. Abdallah,
T. N. Addy,
P. Adragna,
M. Aharrouche,
A. Ahmad,
T. P. A. Akesson,
M. Aleksa,
C. Alexa,
K. Anderson,
A. Andreazza,
F. Anghinolfi,
A. Antonaki,
G. Arabidze,
E. Arik,
T. Atkinson,
J. Baines,
O. K. Baker,
D. Banfi,
S. Baron,
A. J. Barr,
R. Beccherle,
H. P. Beck,
B. Belhorma,
P. J. Bell
, et al. (460 additional authors not shown)
Abstract:
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in…
▽ More
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
△ Less
Submitted 12 May, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam
Authors:
A. Ahmad,
A. Andreazza,
T. Atkinson,
J. Baines,
A. J. Barr,
R. Beccherle,
P. J. Bell,
J. Bernabeu,
Z. Broklova,
P. A. Bruckman de Renstrom,
D. Cauz,
L. Chevalier,
S. Chouridou,
M. Citterio,
A. Clark,
M. Cobal,
T. Cornelissen,
S. Correard,
M. J. Costa,
D. Costanzo,
S. Cuneo,
M. Dameri,
G. Darbo,
J. B. de Vivie,
B. Di Girolamo
, et al. (104 additional authors not shown)
Abstract:
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated u…
▽ More
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignment of the silicon modules is of the order of 5 micrometers in their most precise coordinate.
△ Less
Submitted 26 May, 2008;
originally announced May 2008.
-
System Tests of the ATLAS Pixel Detector
Authors:
K. Reeves,
K. -H. Becks,
T. Flick,
P. Gerlach,
J. Grosse-Knetter,
F. Huegging,
M. Imhaeuser,
S. Kersten,
P. Kind,
K. Lantzsch,
P. Mattig,
I. Rottlaender,
J. Richter,
J. Schultes,
J. Schumacher,
J. Weingarten,
N. Wermes
Abstract:
The innermost part of the ATLAS (A Toroidal LHC ApparatuS) experiment at the LHC (Large Hadron Collider) will be a pixel detector, which is presently under construction. Once installed into the experimental area, access will be extremely limited. To ensure that the integrated detector assembly operates as expected, a fraction of the detector which includes the power supplies and monitoring syste…
▽ More
The innermost part of the ATLAS (A Toroidal LHC ApparatuS) experiment at the LHC (Large Hadron Collider) will be a pixel detector, which is presently under construction. Once installed into the experimental area, access will be extremely limited. To ensure that the integrated detector assembly operates as expected, a fraction of the detector which includes the power supplies and monitoring system, the optical readout, and the pixel modules themselves, has been assembled and operated in a laboratory setting for what we refer to as system tests. Results from these tests are presented.
△ Less
Submitted 5 January, 2006;
originally announced January 2006.
-
Validation Studies of the ATLAS Pixel Detector Control System
Authors:
Joachim Schultes,
Karl-Heinz Becks,
Tobias Flick,
Tobias Henss,
Martin Imhäuser,
Susanne Kersten,
Peter Kind,
Kerstin Lantzsch,
Peter Mättig,
Kendall Reeves,
Jens Weingarten
Abstract:
The ATLAS pixel detector consists of 1744 identical silicon pixel modules arranged in three barrel layers providing coverage for the central region, and three disk layers on either side of the primary interaction point providing coverage of the forward regions. Once deployed into the experiment, the detector will employ optical data transfer, with the requisite powering being provided by a compl…
▽ More
The ATLAS pixel detector consists of 1744 identical silicon pixel modules arranged in three barrel layers providing coverage for the central region, and three disk layers on either side of the primary interaction point providing coverage of the forward regions. Once deployed into the experiment, the detector will employ optical data transfer, with the requisite powering being provided by a complex system of commercial and custom-made power supplies. However, during normal performance and production tests in the laboratory, only single modules are operated and electrical readout is used. In addition, standard laboratory power supplies are used. In contrast to these normal tests, the data discussed here was obtained from a multi-module assembly which was powered and read out using production items: the optical data path, the final design power supply system using close to final services, and the Detector Control System (DCS). To demonstrate the functionality of the pixel detector system a stepwise transition was made from the normal laboratory readout and power supply systems to the ones foreseen for the experiment, with validation of the data obtained at each transition.
△ Less
Submitted 31 October, 2005;
originally announced October 2005.